OMRON SCIENTIFIC TECHNOLOGIES INC.
Fremont CA USA
Tel: 1/888/510-4357 in USA and Canada
© OSTI 1209 PN99584-0050 Rev. E
Original Instructions
67
Figure 14-5
Red = Receiver
Blk = Transmitter
Receiver
Transmitter
Step 2
Identify & separate the transmitter and receiver segments.
For cabled segments, Red connectors are receiver,
Black connectors are transmitter.
Blk = Transmitter
Red = Receiver
Connector
Cable
Filter
Step 1
Unit must be assembled
without power supplied.
face down
Filter
Step 3
Place segment (with cable) lens down on a flat surface.
Optional spacer (STI 83137)
Flat head phillips; M2. 5x11 (STI 90835)
Round head phillips; M3x8 (STI 91141)
Round head phillips; M3x3 (STI 90815)
Note:
2-
2-
2-
The following screws are used for each 90 joint:
Step 4
Each segment may be joined to the left or right.
Filter face down
Step 5 Assemble segments together as shown.
Step 6
Install two flathead phillips screws (90835) as shown.
Step 7
Install two round head phillips screws (91141) as shown.
Step 8.
Install two round head phillips screws (90815) as shown.
Step 9
Use optional mounting spacer (83137) as shown.
Assembly Instructions Steps
14.4.4
I
NSTALLATION
After the unit is assembled in the desired configuration, measure the mounting holes on the configured
system. Confirm these dimensions by using the drawing
&
. The mounting
holes should match within a reasonable tolerance. Use the dimensions from the drawing for proper
alignment.
The first segment is the segment which connects to the power supply/controller. Make sure the first
transmitter is mounted directly across from the first receiver segment. This orientation must continue