![background image](http://html1.mh-extra.com/html/omron/laser-zx/laser-zx_datasheet_743679020.webp)
20
ZX Series (ZX-L-N)
Smart Sensors (Laser Type)
Use Precautions
●
EN60825-1
*With respect to the requirements of remote interlock connector, key control, beam attenuator, and emission indicator, Class 3B laser products not
exceeding five times the AEL of Class 2 in the wavelength range of 400 nm to 700 nm are to be treated as Class 3A laser products.
Note: This table is intended to provide a convenient summary of requirements. See text of this standard for complete precautions.
●
ANSI Z136.1:1993 “American National Standard for the Safe Use of Lasers”
Control Measures for the Four Laser Classes
Requirements;
Sub-clause
Classification
Class 1
Class 2
Class 3A
Class 3B*
Class 4
Remote interlock
Not required
Connect to room or door circuits
Key control
Not required
Remove key when not in use
Beam attenuator
Not required
When in use prevents inadvertent exposure
Emission indicator de-
vice
Not required
Indicates laser is energized
Warning signs
Not required
Follow precautions on warning signs
Beam path
Not required
Terminate beam at end of useful length
Specular reflection
No requirements
Prevent unintentional reflections
Eye protection
No requirements
Required if engineering and administrative procedures not practicable
and MPE exceeded
Protective clothing
No requirements
Sometimes required
Specific requirements
Training
No requirements
Required for all operator and maintenance personnel
Control measures
Classification
Engineering Controls
1
2a
2
3a
3b
4
Protective Housing (4.3.1)
X
X
X
X
X
X
Without Protective Housing (4.3.1.1)
LSO (see note 2) shall establish Alternate Controls
Interlocks on Protective Housing (4.3.2)
✩
✩
✩
✩
X
X
Service Access Panel (4.3.3)
✩
✩
✩
✩
X
X
Key Control (4.3.4)
---
---
---
---
•
X
Viewing Portals (4.3.5.1)
---
---
MPE
MPE
MPE
MPE
Collecting Optics (4.3.5.2)
MPE
MPE
MPE
MPE
MPE
MPE
Totally Open Beam Path (4.3.6.1)
---
---
---
---
X
NHZ
X
NHZ
Limited Open Beam Path (4.3.6.2)
---
---
---
---
X
NHZ
X
NHZ
Enclosed Beam Path (4.3.6.3)
None is required if 4.3.1 and 4.3.2 fulfilled
Remote Interlock Connector (4.3.7)
---
---
---
---
•
X
Beam Stop or Attenuator (4.3.8)
---
---
---
---
•
X
Activation Warning Systems (4.3.9)
---
---
---
---
•
X
Emission Delay (4.3.9.1)
---
---
---
---
---
X
Indoor Laser Controlled Area (4.3.10)
---
---
---
---
X
NHZ
X
NHZ
Class 3b Laser Controlled Area (4.3.10.1)
---
---
---
---
X
---
Class 4 Laser Controlled Area (4.3.10.2)
---
---
---
---
---
X
Laser Outdoor Controls (4.3.11)
---
---
---
---
X
NHZ
X
NHZ
Laser in Navigable Airspace (4.3.11.2)
---
---
---
•
•
•
Temporary Laser Controlled Area (4.3.12)
✩
MPE
✩
MPE
✩
MPE
✩
MPE
---
---
Remote Firing & Monitoring (4.3.13)
---
---
---
---
---
•
Labels (4.3.14 and 4.7)
X
X
X
X
X
X
Area Posting (4.3.15)
---
---
---
•
X
NHZ
X
NHZ
Administrative & Procedural Controls
1
2a
2
3a
3b
4
Standard Operating Procedures (4.4.1)
---
---
---
---
•
X
Output Emission Limitations (4.4.2)
---
---
---
LSO Determination
Education and Training (4.4.3)
---
---
•
•
X
X
Authorized Personnel (4.4.4)
---
---
---
---
X
X
Alignment Procedures (4.4.5)
---
---
X
X
X
X