background image

ZX Series (ZX-L-N)

 

Smart Sensors (Laser Type)

 

1

Smart Sensors (Laser Type)

ZX Series (ZX-L-N)

.

Ordering Information

Sensors

Sensor Heads (Reflective)

Sensor Heads (Through-beam)

Amplifier Units

Note: Compatible connection with the Sensor Head.

Optical system

Beam shape

Sensing distance

Resolution*1

Model

Diffuse reflective

Spot beam

40

±

10 mm

µ

m

ZX-LD40

100

±

40 mm

16 

µ

m

ZX-LD100

300

±

200 mm

300 

µ

m

ZX-LD300

Line beam

40

±

10 mm

µ

m

ZX-LD40L

100

±

40 mm

16 

µ

m

ZX-LD100L

300

±

200 mm

300 

µ

m

ZX-LD300L

Regular reflective

Spot beam

30

±

2 mm

0.25 

µ

m

ZX-LD30V

Line beam

ZX-LD30VL

*1. For an average count of 4,096.

Optical system

Measuring width

Sensing distance

Resolution*1

Model

Through-beam

1-mm dia.

0 to 2000 mm

µ

m

ZX-LT001

5 mm

0 to 500 mm

ZX-LT005

10 mm

ZX-LT010

30 mm

12 

µ

m

ZX-LT030

*1. For an average count of 64.

Appearance

Power supply

Output type

Model

DC

NPN

ZX-LDA11-N

PNP

ZX-LDA41-N

Summary of Contents for LASER ZX -

Page 1: ...m ZX LD40 100 40 mm 16 m ZX LD100 300 200 mm 300 m ZX LD300 Line beam 40 10 mm 2 m ZX LD40L 100 40 mm 16 m ZX LD100L 300 200 mm 300 m ZX LD300L Regular reflective Spot beam 30 2 mm 0 25 m ZX LD30V Li...

Page 2: ...and monitor waveforms Cables with Connectors on Both Ends for Extension 1 1 Robot Cable models are also available The model numbers are ZX XC R 2 For use only with Reflective Sensors Appearance Model...

Page 3: ...s 2 m 16 m 300 m 0 25 m 2 m 16 m 300 m 0 25 m Linearity 3 3 Linearity The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object The...

Page 4: ...t of 32 This is the value that results when a minimum sensing object blocks the light near the center of the 1 mm measurement width 4 m 3 3 For an average count of 64 The value is 5 m for an average c...

Page 5: ...F mode ECO mode number of display digit changes sample hold peak hold bottom hold peak to peak hold self peak hold self bottom hold average hold delay hold intensity mode zero reset initial reset ON d...

Page 6: ...50 g Item ZX SF11 Current consumption 60 mA max supplied by the Amplifier Unit Applicable Amplifier Units ZX Series Applicable Amplifier Unit versions ZX LDA 1 N Ver 1 000 or higher ZX EDA 1 Ver 1 100...

Page 7: ...S304 Black paper inclination inclination Error FS Angle of inclination White ceramic SUS304 Black paper inclination inclination Error FS Angle of inclination White ceramic SUS304 Black paper inclinati...

Page 8: ...lination ZX LD30V Side to side Inclination Front to back Inclination Front to back Inclination ZX LD30VL Side to side Inclination Linearity error FS Linearity error FS Angle of inclination White ceram...

Page 9: ...tion 10 Inclination Front to back White ceramic SUS304 Black paper ZX LD100 0 Inclination 10 Inclination 10 Inclination Front to back 10 Inclination ZX LD300 0 Inclination 10 Inclination Front to back...

Page 10: ...300 340 220 260 180 140 100 ZX LD100L 0 Inclination 10 Inclination Front to back 10 Inclination Error FS Distance mm 0 inclination White ceramic SUS304 Black paper Error FS Distance mm 10 inclination...

Page 11: ...L 30 mm 40 mm 50 mm X 2 000 m 2 000 m 2 000 m Y 240 m 50 0 m 250 m L 60 mm 100 mm 140 mm X 2 000 m 2 000 m 2 000 m Y 410 m 100 m 430 m L 100 mm 300 mm 500 mm X 2 000 m 2 000 m 2 500 m Y 750 m 300 m 6...

Page 12: ...output FS Light axis center Sensing distance 500 mm Sensing object 0 02 mm dia Pin gauge Emitter side Receiver side Linear analog output FS Light axis center Sensing distance 2 m Sensing object 0 05 m...

Page 13: ...12 8 4 0 27 28 30 29 31 32 33 24 20 16 12 8 4 0 27 28 30 29 31 32 33 6 4 2 0 2 4 6 ZX LD40 LD40L Current Output Voltage Output Linear output mA Linear output V Distance mm Distance mm 0 100 300 200 4...

Page 14: ...GND Current output 300 max Voltage output 10 k min Current output 4 to 20 mA Current voltage switch Voltage output 4V Load Load Load 12 to 24 VDC 100 100 Brown White Green Gray Blue Pink Purple Orang...

Page 15: ...Input cable with connector Display area Controls Output cable Connector Cover opens and closes Display area Connector Display area Sensor Heads Through beam ZX LT001 ZX LT005 ZX LT010 ZX LT030 Emitte...

Page 16: ...ction When using a commercially available switching regulator ground the FG frame ground terminal If the power supply line is subject to surges connect a surge ab sorber that meets the conditions of t...

Page 17: ...Class 1 Class 2 Class 3A Class 3B Class 4 Description of hazard class Safe under reason ably foreseeable con ditions Low power eye pro tection normally af forded by aversion responses Same as Class 2...

Page 18: ...it The maximum accessible emission level permitted within a particular class For your reference see ANSI Z136 1 1993 Section 2 Symbol and border black Background yellow Figure A Warning label Hazard s...

Page 19: ...aser products and light shows 12 DANGER logotype 13 Required after August 20 1986 Requirements Class see note 1 I IIa II IIIa IIIb IV Performance all laser products Protective housing R see note 2 R s...

Page 20: ...exceeded Protective clothing No requirements Sometimes required Specific requirements Training No requirements Required for all operator and maintenance personnel Control measures Classification Engin...

Page 21: ...ctive Windows 4 6 3 X NHZ X NHZ Protective Barriers and Curtains 4 6 4 Skin Protection 4 6 5 X MPE X MPE Other Protective Equipment 4 6 5 Use may be required Warning Signs and Labels 4 7 Design Requir...

Page 22: ...excess of 0 25 second pro viding that emissions for other durations and or wavelengths do not ex ceed the Class I limits Class II products are considered hazardous for direct long term ocular exposur...

Page 23: ...rence surface Connector ZX LD40L L 40 mm A 23 ZX LD10L L 100 mm A 11 ZX LD30L L 300 mm A 3 8 Vinyl insulated round cable 5 1 dia Standard 500 mm Range indicators Two 3 2 dia mounting holes Mounting Ho...

Page 24: ...dia Vinyl insulated round cable gray 2 6 dia Standard 500 mm ZX LT001 ZX LT005 Vinyl insulated round cable black 2 6 dia Standard 500 mm 14 20 22 42 2 8 20 20 14 10 25 2 8 20 14 0 1 14 0 1 Two M3 hol...

Page 25: ...wo 4 5 dia Two M3 depth 5 Three M4 x 25 pan head screw 70 50 68 1 10 10 16 22 6 Two 4 5 dia Vinyl insulated round cable 4 dia Standard length 0 5 m 50 0 1500 11 dia 13 2 dia 46 15 dia 43 35 3 Sensor H...

Page 26: ...ately 21 2 8 20 20 20 24 9 19 5 3 9 5 15 44 05 30 15 1 12 8 26 14 4 3 4 36 7 5 54 9 57 15 15 15 15 2 7 10 6 Calculating Unit ZX CAL2 Operation indicators Connectors Side view Attachments ZX XF12 Light...

Page 27: ...s male 12 pins female ZX XC1A 1 000 ZX XC4A 4 000 ZX XC8A 8 000 ZX XC9A 9 000 15 5 dia ZX series Communications Interface Unit ZX SF11 Sensor communications indicator communications operation Sensor c...

Page 28: ...Industrial Automation Company Sensing Devices Division H Q Industrial Sensors Division Shiokoji Horikawa Shimogyo ku Kyoto 600 8530 Japan Tel 81 75 344 7022 Fax 81 75 344 7107 Printed in Japan 0606 0...

Reviews: