K8DT-LS

7

Safety Precautions

Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

 

!

CAUTION

Doing so may occasionally result in minor injury due 
to electric shock. Do not touch the Relay while the 
power supply is ON, except for the adjustment knob.

There is a risk of minor electrical shock, fire, or device 
failure. Do not allow any pieces of metal, conductors, or 
cutting chips that occur during the installation process to 
enter the product.

Explosions may cause minor injuries. Do not use the 
product in locations with inflammable or explosive 
gases.

There is a risk of minor electrical shock, fire, or device 
failure. Do not disassemble, modify, repair, or touch 
the inside of the product.

Use of the product beyond its life may result in 
contact welding or burning. Make sure to consider the 
actual operating conditions and use the product 
within its rated load and electrical life count. The life 
of the output relay varies significantly with the switching 
capacity and switching conditions.

If the Relay is used with incorrect wiring, fire may 
occasionally occur, possibly resulting in physical 
damage. Check the wiring for mistakes before you 
turn ON the power supply.

If the Relay fails, monitoring and alarm outputs may 
fail to operate. This may result in physical damage to 
the facilities, equipment, or other devices that are 
connected to it. To reduce this risk, inspect the Relay 
regularly. To maintain safety in the event of 
malfunction of the Relay, take appropriate safety 
measures, such as installing a monitoring device on a 
separate line.

If the wire insertion length is insufficient, fire may 
occasionally occur, possibly resulting in physical 
damage. Insert the wires all the way to the back.

The terminal block may be damaged if you insert a 
flat-blade screwdriver in the release hole with 
excessive force. Insert the flat-blade screwdriver into 
the release holes with a force of 15 N or less.

 CAUTION

Indicates a potentially hazardous 
situation which, if not avoided, may result 
in minor or moderate injury or in property 
damage.

Precautions for 

Safe Use

Supplementary comments on what to do 
or avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do 
or avoid doing, to prevent failure to 
operate, malfunction, or undesirable 
effects on product performance.

Used to warn of the risk of electric shock under 
specific conditions.

Used for general prohibitions for which there is 
no specific symbol.

Used to indicate prohibition when there is a risk 
of minor injury from electrical shock or other 
source if the product is disassembled.

Used for general mandatory action precautions 
for which there is no specified symbol.

Summary of Contents for K8DT-LS Series

Page 1: ...h bare stranded wires Double insertion holes for crossover wiring all terminals UL listed for easy shipping to North America Models with transistor outputs added for low contact wear Ordering Informat...

Page 2: ...esistance against corrosion For installation at long distances from the liquid level Model PS 3S 4S 5S PS 31 SUS304 300 mm BF 1 BF 3 5 BS 1 BS 1T PH 1 2 Appearance Application Purified water service i...

Page 3: ...insertion force 15 N Wire stripping length 8 mm Ferrule length 8 mm Recommended flat blade screwdriver XW4Z 00B Omron SZF 0 4 2 5 Phoenix Contact 210 719 Wago SDI 0 4 2 5 75 Weidmuller Current capacit...

Page 4: ...E3 E2 DIP SW Power supply AC DC Power supply AC DC Water or other liquid Water or other liquid Three phase power supply Motor Pump Motor Pump Source of liquid Source of liquid Pump motor protection m...

Page 5: ...witch Keep the DIP switch cover closed while the power supply to the Relay is ON Operating time knob Operating resistance knob Power indicator Output status indicator Terminal block See note Terminal...

Page 6: ...g 17 5 90 86 90 5 100 Conductive Level Controller K8DT LS Options Order Separately Front Cover Y92A D1A 52 7 3 5 1 8 17 5 5 85 DIN Tracks PFP 100N PFP 50N Dimensions in parentheses are for the PFP 50N...

Page 7: ...ails monitoring and alarm outputs may fail to operate This may result in physical damage to the facilities equipment or other devices that are connected to it To reduce this risk inspect the Relay reg...

Page 8: ...emember that the power supply terminals carry a high voltage 21 The product must be handled only by trained electrician 22 Prior to operation check the wiring before you supply power to the product 23...

Page 9: ...emove the flat blade screwdriver from the release hole Checking Connections After the insertion pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the...

Page 10: ...ulation between the power supply terminals and input terminals There is basic insulation between the power supply terminals and output terminals There is basic insulation between the input terminals a...

Page 11: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 12: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Reviews: