K8AK-TH

2

Specifications

Ratings

Characteristics

Item

Power supply voltage

100 to 240 VAC 50/60 Hz

24 VAC 50/60 Hz or 24 VDC

Allowable voltage range

85% to 110% of power supply voltage 

Power consumption

5 VA max.

2 W max. (24 VDC), 4 VA max. (24 VAC)

Sensor inputs

K8AK-TH11S

Thermocouple: K, J, T, E; Platinum-resistance thermometer: Pt100, Pt1000

K8AK-TH12S

Thermocouple: K, J, T, E, B, R, S, PLII

Output relay

One SPDT relay (5 A at 250 VAC, resistive load) 

External inputs 
(for latch setting)

Contact input

ON: 1 k

 max., OFF: 100 k

 min. 

Non-contact input

ON residual voltage: 1.5 V max., OFF leakage current: 0.1 mA max.

Leakage current: Approx. 10 mA

Setting method

Rotary switch setting (set of three switches)

Indicators

Power (PWR): Green LED, Relay output (ALM): Red LED 

Other functions

Alarm Mode (upper limit/lower limit), non-fail safe/fail safe selection, output latch, setting protection, temperature 
unit 

°

C/

°

Ambient operating temperature

20 to 55

°

C (with no condensation or icing)

Ambient operating humidity

Relative humidity: 25% to 85%

Storage temperature

25 to 65

°

C (with no condensation or icing)

Measurement accuracy

K8AK-TH11S: 

±

1% of the setting range or 

±

4

°

C, whichever is larger

K8AK-TH12S: 

±

1% of the setting range (

±

1% FS)

hysteresis width

2

°

C

Output relay

Rated load

Resistive load
5 A at 250 VAC
5 A at 30 VDC

Maximum switching capacity: 1,250 VA, 150 W
Minimum load: 5 VDC, 10 mA (reference values)
Mechanical life: 10 million operations min.
Electrical life: 

5 A at 250 VAC or 30 VDC: 50,000 operations 

3 A at 250 VAC/30 VDC: 100,000 operations

Sampling cycle

100 ms

Insulation resistance

20 M

 (at 500 V) between charged terminals and exposed uncharged parts

20 M

 (at 500 V) between any charged terminals (i.e., between input, output, and power supply terminals)

20 M

 (at 500 V) between contacts (open)

Dielectric strength

2,300 VAC, 50/60 Hz for 1 min between terminals of different charge

Vibration resistance

Vibration of 10 to 55 Hz and acceleration of 50 m/s

2

 for 5 min with 10 sweeps each in X, Y, and Z directions

Shock resistance

100 m/s

2

, 3 times each in 6 directions along 3 axes

Weight

Approx. 160 g

Degree of protection

IP20

Memory protection

Non-volatile memory (number of writes: 1 million)

Safety 
Standards

Approved standards

UL 61010-1
Installation environment (pollution level 2, installation category II)

EMC

EN 61326-1

Application standards

UL 61010-1, Korean Radio Waves Act (Act 10564), CSA: C22.2 No.14, CCC: GB14048.5

Terminal screw tightening torque

0.49 to 0.59 N·m

Crimp terminals

Two solid wires of 2.5 mm

2

 or two ferrules of 1.5 mm

2

 with insulation sleeves can be tightened together.

Case color

N1.5

Case material

PC and ABS, UL 94 V-0

Mounting

Mounts to DIN Track.

Dimensions

22.5 

×

 100 

×

 90 mm (W 

×

 D 

×

 H)

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Summary of Contents for K8AK-TH

Page 1: ...or the setting ranges Note When ordering designate the power supply specification Different Relay models are used for 100 to 240 VAC and 24 VAC VDC Refer to Safety Precautions on page 8 For the most r...

Page 2: ...30 VDC Maximum switching capacity 1 250 VA 150 W Minimum load 5 VDC 10 mA reference values Mechanical life 10 million operations min Electrical life 5 A at 250 VAC or 30 VDC 50 000 operations 3 A at...

Page 3: ...setting increment 10 C Input K J T E B R S PLII Setting temperature range 3 200 3 100 3 000 2 900 2 800 2 700 2 600 2 500 2 400 2 300 2 200 2 100 2 000 1 900 1 800 1 700 1 600 1 500 1 400 1 300 1 200...

Page 4: ...ther error Power supply Relay output latched 11 to 14 LATCH_RST or external inputs 4 to 5 Temperature alarm or other error Power supply PWR indicator SV Protect Mode Power supply ALM indicator Tempera...

Page 5: ...e than one million times If you press and hold the LATCH_RST button for 5 seconds or longer the SV Protect Mode will go into effect When SV Protect Mode is enabled the PWR indicator flashes To disable...

Page 6: ...ult All OFF SW8 Not used R_SW3 K8AK TH12S R_SW2 R_SW1 SW 1 2 3 4 K 5 6 7 J T E B R S PLII Input type ON OFF 100 C F units 0 to 9 10 C F units 0 to 9 Upper limit alarm Lower limit alarm With latching W...

Page 7: ...ated The protection function can be released by pressing the output latch reset button on the Temperature Monitoring Relay for at least 5 s or by turning ON the input to the external input terminal fo...

Page 8: ...he side panel take effect when the power is turned ON If the Temperature Monitoring Relay fails monitoring and alarm outputs may fail to operate This may result in physical damage to the facilities eq...

Page 9: ...ring Relay to stabilize Take this time into account when you design the control panel 14 Allow at least 30 minutes for the product to warm up During this time the temperature measurements will be inco...

Reviews: