Safety Precautions

Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

Electrical shock may cause minor injury.
Do not touch terminals while electricity is being supplied.

There is a risk of minor electrical shock, fire, or device failure. 
Do not allow any pieces of metal, conductors, or cutting chips 
that occur during the installation process to enter the product.

Explosions may cause minor injuries. Do not use the product  
in locations with inflammable or explosive gases.

There is a risk of minor electrical shock, fire, or device failure. 
Do not disassemble, modify, repair, or touch the inside of the 
product.

Loose screws may cause fires. Tighten terminal screws to the 
specified torque of 0.49 to 0.59 N·m.

Use of excessive torque may damage the terminal screws. 
Tighten terminal screws to the specified torque of 0.49 to 
0.59 N·m.

Use of the product beyond its life may result in contact welding 
or burning. Make sure to consider the actual operating 
conditions and use the product within its rated load and 
electrical life count. The life of the output relay varies 
significantly with the switching capacity and switching 
conditions.

 CAUTION

Indicates a potentially hazardous situation 
which, if not avoided, may result in minor or 
moderate injury or in property damage.

Precautions for Safe 

Use

Supplementary comments on what to do or 
avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do or 
avoid doing, to prevent failure to operate, 
malfunction, or undesirable effects on 
product performance.

Used to warn of the risk of electric shock under 
specific conditions.

Used for general prohibitions for which there is no 
specific symbol.

Used to indicate prohibition when there is a risk of 
minor injury from electrical shock or other source if 
the product is disassembled.

Used for general mandatory action precautions for 
which there is no specified symbol.

 CAUTION

Summary of Contents for K8AK-AW Series

Page 1: ...ent Transformer CT Direct input is not possible Accessory Order Separately OMRON CT Commercially Available CTs If you use a commercially available CT do not exceed the overload capacity of the K8AK AW...

Page 2: ...mA AC DC 50 to 500 mA AC DC Approx 5 Direct input Continuous input at 120 of maximum input 1 s at 150 0 to 100 mA AC DC I2 COM Approx 1 Direct input 0 to 500 mA AC DC I3 COM Approx 0 2 Direct input K...

Page 3: ...puts ALM Red Input impedance Refer to Input Range on previous page Output relays Two SPDT relay outputs normally closed operation Output relay ratings Rated load Resistive load 5 A at 250 VAC 5 A at 3...

Page 4: ...minals Between input terminals and output terminals Dielectric strength 2 000 VAC for one minute Between external terminals and case Between power supply terminals and input terminals Between power su...

Page 5: ...er CT Wiring Example Directly Inputting a Current Using a CT K8AK AW1 100 240VAC A B Control Output Relay output 250 VAC 5 A resistive load 30 VDC 5 A resistive load A Current Input AW1 Relay Output C...

Page 6: ...operative Note 2 The startup lock prevents unnecessary alarms from being generated during the unstable period when the power is first turned ON There is no contact output during timer operation Flash...

Page 7: ...nal block See notes 1 and 2 Alarm indicator Current knob AL2 Item Meaning Power indicator PWR Green Lit when power is being supplied Relay status indicator RY Yellow Lit when relay is operating Alarm...

Page 8: ...ched the same level Use this as a guide to set the current The maximum setting range will differ depending on the model and the input terminal Example K8AK AW3 Using Input Terminals I3 COM The maximum...

Page 9: ...de to set the startup lock time The startup lock time will start when the input current reaches 30 or more of the set value Use startup lock time to prevent unwanted operation e g as a result of inrus...

Page 10: ...figure for information on the motor startup current For a motor with a rating of 5 A the startup current will be approximately 30 A The startup current will exceed the overload capacity rating 150 for...

Page 11: ...cified torque of 0 49 to 0 59 N m Use of the product beyond its life may result in contact welding or burning Make sure to consider the actual operating conditions and use the product within its rated...

Page 12: ...ifficult to see 15 Do not use the product if it is accidentally dropped The internal components may be damaged 16 Be sure you understand the contents of this catalog and handle the product according t...

Page 13: ...MEMO 13...

Page 14: ...MEMO 14...

Page 15: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 16: ...A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Tokyo JA...

Reviews: