Single-phase Voltage Relay

 

K8AB-VW

Cat. No. N144-E1-02

Ordering Information

List of Models

Note:

Models with a 24-VDC power supply have a non-isolated power supply. 
The inputs and power supply are connected internally, so a malfunction may occur due to an unwanted current path if the inputs and power 
supply are connected to the same line.
If an unwanted current path exists, use a K8AB AC Power Supply or isolate with an external power supply.

Ratings and Specifications

Input Range

Single-phase Voltage Relay

Measuring voltage 

Supply voltage

Model

6 to 60 mV AC/DC, 
10 to 100 mV AC/DC, 
30 to 300 mV AC/DC

24 VDC, not insulated

K8AB-VW1 24 VDC (See note.)

24 VAC, insulated

K8AB-VW1 24 VAC

100-115 VAC, insulated

K8AB-VW1 100-115 VAC

200-230 VAC, insulated

K8AB-VW1 200-230 VAC

1 to 10 V AC/DC, 
3 to 30 V AC/DC, 
15 to 150 V AC/DC

24 VDC, not insulated

K8AB-VW2 24 VDC (See note.)

24 VAC, insulated

K8AB-VW2 24 VAC

100-115 VAC, insulated

K8AB-VW2 100-115 VAC

200-230 VAC, insulated

K8AB-VW2 200-230 VAC

20 to 200 V AC/DC, 
30 to 300 V AC/DC, 
60 to 600 V AC/DC

24 VDC, not insulated

K8AB-VW3 24 VDC (See note.)

24 VAC, insulated

K8AB-VW3 24 VAC

100-115 VAC, insulated

K8AB-VW3 100-115 VAC

200-230 VAC, insulated

K8AB-VW3 200-230 VAC

Model

Range

Connection terminal

Input impedance

Overload capacity

K8AB-VW1

6 to 60 mV AC/DC

V1-COM

Approx. 220 k

115% max. input continuous
125% max. input for 10 s

10 to 100 mV AC/DC V2-COM

Approx. 230 k

30 to 300 mV AC/DC V3-COM

Approx. 260 k

K8AB-VW2

1 to 10 V AC/DC

V1-COM

Approx. 120 k

3 to 30 V AC/DC

V2-COM

Approx. 320 k

15 to 150 V AC/DC

V3-COM

Approx. 1.6 M

K8AB-VW3

20 to 200 V AC/DC

V1-COM

Approx. 1.2 M

30 to 300 V AC/DC

V2-COM

Approx. 1.7 M

60 to 600 V AC/DC

V3-COM

Approx. 3.1 M

Summary of Contents for K8AB-VW Series

Page 1: ...Process control signal 0 to 10 V and current splitter input supported Output status can be monitored using LED indicator Input frequency of 40 to 500 Hz supported Model Number Structure Model Number Legend 1 Basic Model K8AB Measuring and Monitoring Relays 2 Functions VW Single phase Voltage Relay Simultaneous upper and lower limit monitoring 3 Measuring Current 1 6 to 60 mV AC DC 10 to 100 mV AC ...

Page 2: ... K8AB VW1 200 230 VAC 1 to 10 V AC DC 3 to 30 V AC DC 15 to 150 V AC DC 24 VDC not insulated K8AB VW2 24 VDC See note 24 VAC insulated K8AB VW2 24 VAC 100 115 VAC insulated K8AB VW2 100 115 VAC 200 230 VAC insulated K8AB VW2 200 230 VAC 20 to 200 V AC DC 30 to 300 V AC DC 60 to 600 V AC DC 24 VDC not insulated K8AB VW3 24 VDC See note 24 VAC insulated K8AB VW3 24 VAC 100 115 VAC insulated K8AB VW3...

Page 3: ...elay output RY Yellow Alarm outputs ALM Red Input impedance Refer to the Input Range on the previous page Output relays Two SPDT relays NC operation Output relay ratings Rated load Resistive load 6 A at 250 VAC cosφ 1 6 A at 30 VDC L R 0 ms Inductive load 1 A at 250 VAC cosφ 0 4 1 A at 30 VDC L R 7 ms Maximum contact voltage 250 VAC Maximum contact current 6 A AC Maximum switching capacity 1 500 V...

Page 4: ...ly voltage Operating value 5 max Operating time 10 max Note The error in the operating value and operating time under standard conditions Influence of power supply frequency Operating value 5 max at 45 to 65 Hz Operating time 10 max at 45 to 65 Hz Note The error in the operating value and operating time under standard conditions Influence of input frequency At 40 to 500 Hz Operating value 5 max Op...

Page 5: ...ing timer operation Note The 24 VDC power supply type is a non insulated power supply The inputs and power supply are connected internally so a malfunction may occur due to an unwanted current path if the inputs and power supply are connected to the same line T T1 T AL1 alarm indicator Overvoltage AL1 relay Input Undervoltage AL2 relay Overvoltage setting AL1 Undervoltage set value AL2 Hysteresis ...

Page 6: ...ator Terminal block See notes 1 and 2 Terminal block See notes 1 and 2 Item Meaning Power indicator PWR Green Lit when power is being supplied Relay status indicator RY Yellow Lit when relay operates Not light when both AL1 and AL2 are in error status Normally lit Alarm indicators AL1 and AL2 Red Lit when there is an overvoltage or undervoltage The indicator flashes to indicate the error status af...

Page 7: ... to terminals 21 22 and 24 Note Use the recommended ferrules if using twisted wires DIP Switch Settings The power ON lock time resetting method and operating mode are set using the DIP switch located on the bottom of the Unit Model Measuring current Wiring connection K8AB VW1 6 to 60 mV AC DC V1 COM 10 to 100 mV AC DC V2 COM 30 to 300 mV AC DC V3 COM K8AB VW2 1 to 10 V AC DC V1 COM 3 to 30 V AC DC...

Page 8: ...Example K8AB VW3 Using Input Terminal V3 COM The maximum measuring voltage will be 600 VAC VDC and the setting range will be 60 to 600 V 2 Operating Time The operating time is set using the operating time knob T The operating time can be set to between 0 1 and 30 s Turn the knob while there is an input to the input terminals until the alarm indicator flashes when the set value and the input have r...

Page 9: ...ks 2 Make sure to use setting values appropriate for the controlled object Failure to do so can cause unintended operation and may result in accident or corruption of the product 3 Do not use thinner or similar solvent for cleaning Use commercial alcohol 4 When discarding properly dispose of the product as industrial waste 5 Only use this product within a board whose structure allows no possibilit...

Page 10: ...an unwanted current path exists If an unwanted current path exists use a K8AB model with an AC power supply or use an isolated DC power supply Using Multiple K8AB Relays with a DC Power Supply The input and power supply must be isolated The input and power supply are connected internally so an unwanted current path will be created if more than one K8AB is used with one DC power supply as shown in ...

Page 11: ...ment or addition to the above warranty See http oeweb omron com or contact your Omron representative for pub lished information 14 Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE ...

Page 12: ...LOQHU YHQXH 7RURQWR 2QWDULR 0 9 20521 7521 6 2QH RPPHUFH ULYH 6FKDXPEXUJ RU 86 WHFKQLFDO VXSSRUW RU RWKHU LQTXLULHV RPSOHWH 7HUPV DQG RQGLWLRQV RI 6DOH IRU SURGXFW SXUFKDVH DQG XVH DUH RQ 2PURQ V ZHEVLWH DW ZZZ RPURQ FRP RHL XQGHU WKH ERXW 8V WDE LQ WKH HJDO 0DWWHUV VHFWLRQ 0 16 216 6 2 1 5 1 0 0 7 56 7R FRQYHUW PLOOLPHWHUV LQWR LQFKHV PXOWLSO E 7R FRQYHUW JUDPV LQWR RXQFHV PXOWLSO E ...

Reviews: