Ultra-slim Signal Converter

 K3FP Series

1

Ultra-slim Signal Converter

K3FP Series

Complete Lineup of Ultra-slim, High-
performance Converters for Every 
Application

• Ultra-slim 6.2-mm size.

Close mounting makes devices more compact.

• Easily wired and flexible with 8 terminal blocks.

• Multi-range I/O provides flexibility for the desired signal format.

• High-precision analog conversion with minimum current 

consumption.

• Reduced wiring through power supply connection with DIN rail 

bus connector (optional).

Product Selection

Product

Model

Input signal

Output signal

Power supply 

voltage

Reference 

page

3-Way Signal Isolator

K3FP-YV-I-I

0 (4) to 20 mA DC

0 (4) to 20 mA DC

24 V DC

3

3-Way Signal Isolator

K3FP-YV-U-U

10 (0) to 10 V DC

10 (0) to 10 V DC

24 V DC

3-Way Signal Isolator

K3FP-VS-UI-UI

0 to 20 mA DC, 4 to 20 mA DC, 
0 to 10 V DC, 2 to 10 V DC, 
0 to 5 V DC, 1 to 5 V DC 
(selected by DIP switch setting)

0 to 20 mA DC, 4 to 20 mA DC, 
0 to 10 V DC, 2 to 10 V DC, 
0 to 5 V DC, 1 to 5 V DC
(selected by DIP switch setting)

24 V DC

6

Dual Output 3-Way Signal 
Isolator

K3FP-VS-UI-2I

0 to 20 mA DC, 4 to 20 mA DC, 
0 to 10 V DC, 1 to 5 V DC
(selected by DIP switch setting)

0 to 20 mA DC, 4 to 20 mA DC
(selected by DIP switch setting)

24 V DC

10

Loop-powered Isolator 
(1-channel)

K3FP-SN1-I-I

0 (4) to 20 mA DC

0 (4) to 20 mA DC

---

14

Loop-powered Isolator 
(2-channel)

K3FP-SN2-I-I

0 (4) to 20 mA DC

0 (4) to 20 mA DC

---

Thermocouple Transducer

K3FP-TS-UI

Type J and K Thermocouples 
(Conforms to IEC 60584-1)
(Input temperature range is 
selected by DIP switch setting.)

0 to 20 mA DC, 4 to 20 mA DC, 
20 to 0 mA DC, 20 to 4 mA DC, 
0 to 5 V DC, 1 to 5 V DC, 
0 to 10 V DC, 10 to 0 V DC 
(selected by DIP switch setting)

24 V DC

17

RTD Transducer

K3FP-RS-UI

PT100 Platinum Resistance 
Thermometer
(Conforms to IEC 60751)
(Input temperature range is 
selected by DIP switch setting.)

0 to 20 mA DC, 4 to 20 mA DC, 
20 to 0 mA DC, 20 to 4 mA DC, 
0 to 5 V DC, 1 to 5 V DC, 
0 to 10 V DC, 10 to 0 V DC
(selected by DIP switch setting)

24 V DC

23

Repeater Power Supply

K3FP-DY-I-I

0 (4) to 20 mA DC

0 (4) to 20 mA DC

24 V DC

30

Limit Value Switch

K3FP-SL-UI

0 to 20 mA DC, 0 to 10 V DC 
(selected by DIP switch setting)

SPDT output 

24 V DC

33

Summary of Contents for K3FP Series

Page 1: ...ted by DIP switch setting 24 V DC 6 Dual Output 3 Way Signal Isolator K3FP VS UI 2I 0 to 20 mA DC 4 to 20 mA DC 0 to 10 V DC 1 to 5 V DC selected by DIP switch setting 0 to 20 mA DC 4 to 20 mA DC sele...

Page 2: ...limited space such as where expansion is required and help to reduce the overall size of devices K3FP RS UI RTD Transducer K3FP VS UI UI Dual Output 3 Way Signal Isolator K3FP VS UI 2I K3FP SL UI Lim...

Page 3: ...P YV U U Name Model DIN rail bus connector K3FP 1 1 2 K3FP YV I I 1 2 K3FP YV U U Item Model K3FP YV I I K3FP YV U U Supply voltage 24 V DC Allowable supply voltage range 80 to 125 of rated supply vol...

Page 4: ...EN 61000 4 4 Surge immunity EN 61000 4 5 Conducted disturbance immunity EN 61000 4 6 Item Model K3FP YV I I K3FP YV U U Input signal Item 0 4 to 20 mA DC 10 0 to 10 V DC Input impedance Approx 50 Appr...

Page 5: ...Output signal Supply voltage 93 1 6 2 102 5 K3FP YV I I K3FP YV U U Note 1 Use solid wire with a diameter of 2 5 mm2 max or bar terminals with insulation sleeves for terminal connections To preserve...

Page 6: ...itch setting Ratings and Specifications Ratings and Specifications Name Model 3 Way Signal Isolator K3FP VS UI UI Name Model DIN rail bus connector K3FP 1 1 2 3 K3FP VS UI UI Supply voltage 24 V DC Al...

Page 7: ...000 4 5 Conducted disturbance immunity EN 61000 4 6 Input signal Item 0 to 20 mA DC 4 to 20 mA DC 0 to 10 V DC 2 to 10 V DC 0 to 5 V DC 1 to 5 V DC Input impedance Approx 50 Approx 100 k Max input sig...

Page 8: ...utput signal 0 to 10 V 0 to 20 mA 4 to 20 mA 0 to 10 V 2 to 10 V 0 to 5 V 1 to 5 V 2 to 10 V 0 to 20 mA 4 to 20 mA 0 to 10 V 2 to 10 V 0 to 5 V 1 to 5 V 0 to 5 V 0 to 20 mA 4 to 20 mA 0 to 10 V 2 to 1...

Page 9: ...ustments have been made is less than 0 4 but if the potentiometer for adjustment is used the error can be reduced to less than 0 1 1 2 3 4 5 6 7 K3FP 1 8 Input signal Supply voltage Output signal Supp...

Page 10: ...ual Output 3 Way Signal Isolator K3FP VS UI 2I Name Model DIN rail bus connector K3FP 1 1 2 3 K3FP VS UI 2I Supply voltage 24 V DC Allowable supply voltage range 80 to 125 of rated supply voltage Curr...

Page 11: ...N 61000 4 3 Burst immunity EN 61000 4 4 Surge immunity EN 61000 4 5 Conducted disturbance immunity EN 61000 4 6 Input signal Item 0 to 20 mA DC 4 to 20 mA DC 0 to 10 V DC 1 to 5 V DC Input impedance A...

Page 12: ...t operation Limit function disabled Limit function enabled Output 1 signal Output 2 signal 0 to 20 mA 0 to 20 mA 0 to 20 mA 4 to 20 mA 4 to 20 mA 4 to 20 mA Output signal selection Below measurement r...

Page 13: ...e pin 4 on DIP switch S1 turned ON The diagnostics indicator flashes to indicate parameter memory errors If this occurs the Unit must be inspected at the factory 93 1 6 2 102 5 K3FP VS UI 2I Note 1 U...

Page 14: ...K3FP SN2 I I Name Model DIN rail bus connector K3FP 1 1 2 3 K3FP SN1 I I K3FP SN2 I I 0 4 8 12 16 20 4 8 12 16 20 Input current mA K3FP SN I I Output current mA Item Model K3FP SN1 I I K3FP SN2 I I E...

Page 15: ...5 Conducted disturbance immunity EN 61000 4 6 Item Model K3FP SN1 I I K3FP SN2 I I Item Input signal 0 to 20 mA DC 4 to 20 mA DC Input impedance Changes depending on the load on the output side Respon...

Page 16: ...icient to drive the maximum current of 20 mA via the Loop powered Isolator with a voltage drop UV of 1 7 V and a load RB Thus UB UE 1 7 V 20 mA RB 93 1 6 2 102 5 K3FP SN1 I I K3FP SN2 I I Note 1 Use s...

Page 17: ...nd Specifications Name Model Thermocouple Transducer K3FP TS UI Name Model DIN rail bus connector K3FP 1 1 2 K3FP TS UI Supply voltage 24 V DC Allowable supply voltage range 80 to 125 of rated supply...

Page 18: ...y EN 61000 4 5 Conducted disturbance immunity EN 61000 4 6 Input signal Item Type J and K Thermocouples Conforms to IEC 60584 1 Measurement range J 150 to 1 200 C K 150 to 1 350 C Minimum measurement...

Page 19: ...to select the current output and voltage output for output signals SWITCH DIP switch S1 ON OFF 1 2 3 4 5 6 7 8 Thermocouple type Type J Type K Cold junction compensation enable disable Enabled Disable...

Page 20: ...4 150 302 160 320 170 338 180 356 190 374 200 392 210 410 220 428 230 446 240 464 250 482 260 500 270 518 280 536 290 554 300 572 320 608 Output status for errors A B C D SWITCH DIP switch S2 ON OFF 1...

Page 21: ...tput Output status for errors DIP switch S2 When disconnected on thermocouple side Above measurement range Below measurement range 7 8 A 21 mA 20 5 mA 0 mA B 21 mA 20 5 mA 0 mA C 21 mA 20 mA 0 mA D 0...

Page 22: ...with a diameter of 2 5 mm2 max or bar terminals with insulation sleeves for terminal connections To preserve dielectric strength after connection the length of the exposed conductive part inserted int...

Page 23: ...V DC 10 to 0 V DC selected by DIP switch setting Ratings and Specifications Ratings and Specifications Name Model RTD Transducer K3FP RS UI Name Model DIN rail bus connector K3FP 1 1 2 K3FP RS UI Supp...

Page 24: ...meter conforms to IEC 60751 Measurement range 150 to 850 C Min measurement span Min 50 C Max input signal 30 V Connection method 2 conductor 3 conductor or 4 conductor Sensor input current 1 mA Max pe...

Page 25: ...current and voltage outputs for output signals SWITCH DIP switch S1 ON OFF 1 2 3 4 5 6 7 8 Connection method 2 conductor 2 conductor 3 conductor 4 conductor Output signal range 0 to 20 mA 20 to 0 mA 4...

Page 26: ...185 90 194 95 203 100 212 110 230 120 248 130 266 140 284 150 302 160 320 170 338 180 356 190 374 200 392 210 410 Output status for errors A B C D SWITCH DIP Switch S2 ON OFF 1 2 3 4 5 6 7 8 End tempe...

Page 27: ...output Output status for errors DIP switch S2 When disconnected on platinum resistance thermometer side Above measurement range Below measurement range When short circuited on platinum resistance the...

Page 28: ...5 25 V 5 125 V 0 875 V 0 75 V C 5 25 V 5 V 1 V 5 25 V D 1 V 5 V 1 V 1 V 1 2 3 4 K3FP 1 4 conductor PT100 3 conductor PT100 2 conductor PT100 5 6 Output signal 7 8 Supply voltage 93 1 6 2 102 5 K3FP R...

Page 29: ...0 platinum resistance thermometers and K3FP RS UI RTD Transducers The value of all cable resistances must be exactly the same to balance out the PT100 platinum resistance thermometer cable resistances...

Page 30: ...V DC Allowable supply voltage range 80 to 125 of rated supply voltage Current consumption 40 mA DC max at 24 V DC including 20 mA load current Power consumption 600 mA max Error 0 2 FS max Temperatur...

Page 31: ...to 20 mA DC Input impedance Approx 50 Max input signal 50 mA Transmitter supply voltage Power supply voltage 4 5 V max Transmitter supply current 28 mA max Overcurrent detection Approx 28 mA Output s...

Page 32: ...Note 1 Use solid wire with a diameter of 2 5 mm2 max or bar terminals with insulation sleeves for terminal connections To preserve dielectric strength after connection the length of the exposed conduc...

Page 33: ...Supply voltage 24 V DC Allowable supply voltage range 80 to 125 of rated supply voltage Current consumption 15 mA DC max at 24 V DC Power consumption 450 mW max Error 0 05 FS max Temperature coeffici...

Page 34: ...DT Contact output status display Yellow indicator LED Applicable load 250 V AC 2 A Contact material AgSnO2 Max contact voltage 250 V AC Max contact current 2 A Max switching capacity 500 VA 250 V AC M...

Page 35: ...teresis contact operation delay time and contact drive method Connections Internal Block Diagram SWITCH DIP switch S1 ON OFF 1 2 3 4 5 6 7 8 Input signal 0 to 10 V 0 to 20 mA Hysteresis 0 1 1 0 2 5 5...

Page 36: ...eter of 2 5 mm2 max or bar terminals with insulation sleeves for terminal connections To preserve dielectric strength after connection the length of the exposed conductive part inserted into the termi...

Page 37: ...on DIP Switch S1 Is ON Setting Method 1 Set the input signal hysteresis contact operation delay time and contact drive method using the DIP switch 2 Mount the Unit to DIN rail and wire it 3 Apply a r...

Page 38: ...l it as close to the product as possible 5 Do not use organic solvents e g thinners or benzene strong alkaline or strong acidic material on the outside of the product Doing so will damage the outer co...

Page 39: ...existing DIN rail bus connection needs to be disconnected Refer to the Internal Block Diagram for each product for block diagrams Be sure that the DIN rail is mounted securely with no loose screws If...

Page 40: ...roduct on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY...

Page 41: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron K3FP YV U U...

Reviews: