Mini Motor Contactor 

J7KNA

System overview

Mini Motor Contactors

AC Operated

DC Solenoid Operated

Auxiliary contact blocks with screw terminals for contactors J7KNA-09... and J7KNA-12...

Link modules for electric connection between MPCB and contactors

Ratings

Rated Current Aux. Contacts

Type

Pack

Weight

AC2, AC3 

AC3

AC1

380V
400V
415V
kW

500V
kW

660V
690V
kW

400V
A

690V
A

NO

NC

Suitable 
Overload 
Relay

*1

*1) For details see datasheet J7TKN Thermal Overload Relay

Coil Voltage

*2

24

24V 50/60Hz

230

220-230V 50Hz

*2) Other coil voltages see 

page 5

pcs.

kg/pc.

3-pole, With Screw Terminals

4

4

4

9

20

1

-

J7TKN-A J7KNA-09-10-

#####

 

10

0.16

5.5

5.5

5.5

12

20

1

-

J7TKN-A J7KNA-12-10-

#####

 

10

0.16

4

4

4

9

20

-

1

J7TKN-A J7KNA-09-01-

#####

 

10

0.16

5.5

5.5

5.5

12

20

-

1

J7TKN-A J7KNA-12-01-

#####

 

10

0.16

4-pole, With Screw Terminals

4

4

4

9

20

-

-

J7TKN-A J7KNA-09-4-

#####

 

10

0.19

Ratings

Rated Current Aux. Contacts

Type

Pack

Weight

AC2, AC3 

AC3

AC1

380V
400V
415V
kW

500V
kW

660V
690V
kW

400V
A

690V
A

NO

NC

Suitable 
Overload 
Relay

*1

*1) For details see datasheet J7TKN Thermal Overload Relay

Coil voltage 24V DC 2,5W

pcs.

kg/pc.

3-pole, With Screw Terminals

4

4

4

9

20

1

-

J7TKN-A J7KNA-09-10-

###

D(-VS)

*2

*2) with built-in coil suppressor (diode + zener diode)

 

10

0.19

5.5

5.5

5.5

12

20

1

-

J7TKN-A J7KNA-12-10-

###

D(-VS)

*2

 

10

0.19

4

4

4

9

20

-

1

J7TKN-A J7KNA-09-01-

###

D(-VS)

*2

 

10

0.19

5.5

5.5

5.5

12

20

-

1

J7TKN-A J7KNA-12-01-

###

D(-VS)

*2

 

10

0.19

Contacts

Rated Current

Thermal Rated Current Type

Pack

Weight

NO

NC

AC15
230V
A

400V
A

A

pcs.

kg/pc.

1

1

3

2

10

J73KN-AM-11

 

10

0.04

-

2

3

2

10

J73KN-AM-02

 

10

0.04

2

2

3

2

10

J73KN-AM-22

 

10

0.04

Description

Version
for contactors

For MPCB

Type

Pack 
pcs

Weight 
approx. 
kg/pc

link module (electrical and 
mechanical connection) 
See datasheet J7MN Motor 
Protection Circuit Breaker

J7KNA 09-...12

J7MN 12 / J7MN 25

J74MN-VK1 12-25

1

0.015

Summary of Contents for J7KNA -

Page 1: ...AC24V 50 60Hz 48 AC48V 50Hz 60 AC60V 50Hz 110 AC110 115V 50Hz AC120 125V 60Hz 180 AC180 210V 50Hz AC200 240V 60Hz 230 AC220 230V 50Hz AC240V 60Hz 240 AC230V 240V 50Hz 400 AC380 400V 50Hz AC440V 60Hz...

Page 2: ...4 4 9 20 J7TKN A J7KNA 09 4 10 0 19 Ratings Rated Current Aux Contacts Type Pack Weight AC2 AC3 AC3 AC1 380V 400V 415V kW 500V kW 660V 690V kW 400V A 690V A NO NC Suitable Overload Relay 1 1 For detai...

Page 3: ...A 11 1 1 1 1 Contacts according to DIN EN 50005 J73KN A 02 0 2 0 2 J73KN A 40 4 0 4 0 J73KN A 22 2 2 2 2 J73KN A 04 0 4 0 4 Wiring Diagrams Auxiliary Contact Blocks Contactor with Auxiliary Contact Co...

Page 4: ...5 5 5 12 20 1 J7TKN A J7KNA 12 01 R 1 0 32 Ratings Rated Current Aux Contacts Type Pack Weight AC2 AC3 AC3 AC1 380V 400V 415V kW 500V kW 660V 690V kW 400V A 690V A NO NC Suitable Overload Relay 1 1 F...

Page 5: ...ide Distinc Number according to DIN EN 50012 Contactor K1 Type NO NC Contactor K2 Type NO NC 3 pole With Screw Terminals 01 J73KN AM 11V 1 1 J73KN AM 11X 1 1 Wiring Diagrams Contacts suitable for Elec...

Page 6: ...6 16 Rated operational power of three phase resistive loads 230V kW 6 3 6 3 50 60Hz cos 1 240V kW 6 7 6 7 400V kW 11 11 415V kW 11 5 11 5 Minimum cross section of conductor at load with Ie Ith mm 2 5...

Page 7: ...0 Short circuit protection for contactors without thermal overload relay Coordination type 1 according to IEC 947 4 1 Contact welding without hazard of persons max fuse size gL gG A 40 40 Coordination...

Page 8: ...0 15 0 25 Resistance to shock according to IEC 68 2 27 Shock time 20ms sine wave AC operated NO g 5 5 NC g 5 5 DC operated NO g 8 8 NC g 6 6 1 Suitable at 690V for earthed neutral systems overvoltage...

Page 9: ...0 4 0 4 0 4 220V A 0 1 0 1 0 1 Maximum ambient temperature Operation open C 40 to 60 90 3 enclosed C 40 to 40 Storage C 40 to 90 Short circuit protection short circuit current 1kA contact welding not...

Page 10: ...e when suppressor units for voltage peak protection are used Varistor RC units Diode units Mini Motor Contactors Data according to IEC 947 5 1 VDE 0660 EN 60947 5 1 Auxiliary Contacts Type J7KNA 09 J7...

Page 11: ...ontactor J7KNA 11 Dimensions AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA 09 J7KNA 12 J73KN A Reversing Contactors J7KNA 09 01 R J7KNA 12 01 R J7KNA 09 01 R J7TKN A J7KNA 12...

Page 12: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into oun...