background image

 

Mini Motor Contactor

 

J7KNA

1

Mini Motor Contactor

J7KNA

Main contactor

• AC & DC operated

• Integrated auxiliary contacts

• Screw fixing and snap fitting (35 mm DIN-rail)

• Range from 4 to 5.5 kW (AC 3, 380/415V)

• 4 -main pole version (4 kW AC and DC coil)

• Auxiliary contacts suitable for electronic devices (DIN 19240)

• Finger proof (BGV A2) 

Accessories

• 2 and 4 pole additional auxiliary contacts in different 

configurations

• Mechanical interlock (in reversing contactor combination only)

• RC Suppressors

• Link modules for fuseless Load Feeders

• Insulated wiring systems (parallel, Star-delta combinations)

)

Approved Standards

Ordering Information

Model Number Legend

1. Mini Motor Contactors

1)

Mini Contactor

2)

Rated Motor Current (AC3 400V)
09:

9A

12: 12A

3)

Integrated auxiliary contact
10: 

1 NC 0  NC

01: 

0 NO 1NC

4: 

4 main pole type (no aux contact)

4)

R:

Reversing Contactor

5)

Coil voltage (AC operated)

1)

24:

AC24V 50/60Hz

48:

AC48V 50Hz

60:

AC60V 50Hz

110:

AC110-115V 50Hz, AC120-125V 60Hz 

180:

AC180-210V 50Hz, AC200-240V 60Hz

230:

AC220-230V 50Hz, AC240V 60Hz

240:

AC230V-240V 50Hz

400:

AC380-400V 50Hz, AC440V 60Hz

415:

AC400-415V 50Hz

Coil voltage  (DC operated)
24D:

DC24V

48D:

DC48V

60D:

DC60V

110D: DC110V 
24VS: DC24V with diode
48VS: DC48V with diode
110VS: DC110V with diode
125VS: DC125V with diode

2. Aux. Contact Modules for Mini Motor Contactors

1)

Auxiliary Contact Modules 

2)

A:

for mini motor contactor (DIN EN 50005)

AM:

for mini motor contactor (DIN EN 50012)

3)

Combination of NO/NC contacts
11:

1 NO 1 NC

02:

0 NO 2 NC

04:

0 NO 4 NC

22:

2 NO 2 NC

40:

4 NO 0 NC

4)

for Reversing Contactors
v:

left side

x:

right side

3. Insulated wiring systems for motor contactors

1)

Additional reference for LVSG

2)

Wiring system

3)

Combination of 2 contactors parallel or reverse, type:
11 = J7KNA 09 -..12
Star-Delta contactors, type:
12 = J7KNA 09 -..12

Standard

Guide No (US,C)

UL

NLDX, NLDX7

ICE 947-5-1

VDE 0660

EN 60947-5-1

1)

See datasheet J7KN Motor Contactor for RC-suppressor units.

J7KNA-

##

-

## #####

1

2

3

4

J73KN-

##

-

##

1

2

3

J75-WK-

##

 1   2

3

Summary of Contents for J7KNA -

Page 1: ...AC24V 50 60Hz 48 AC48V 50Hz 60 AC60V 50Hz 110 AC110 115V 50Hz AC120 125V 60Hz 180 AC180 210V 50Hz AC200 240V 60Hz 230 AC220 230V 50Hz AC240V 60Hz 240 AC230V 240V 50Hz 400 AC380 400V 50Hz AC440V 60Hz...

Page 2: ...4 4 9 20 J7TKN A J7KNA 09 4 10 0 19 Ratings Rated Current Aux Contacts Type Pack Weight AC2 AC3 AC3 AC1 380V 400V 415V kW 500V kW 660V 690V kW 400V A 690V A NO NC Suitable Overload Relay 1 1 For detai...

Page 3: ...A 11 1 1 1 1 Contacts according to DIN EN 50005 J73KN A 02 0 2 0 2 J73KN A 40 4 0 4 0 J73KN A 22 2 2 2 2 J73KN A 04 0 4 0 4 Wiring Diagrams Auxiliary Contact Blocks Contactor with Auxiliary Contact Co...

Page 4: ...5 5 5 12 20 1 J7TKN A J7KNA 12 01 R 1 0 32 Ratings Rated Current Aux Contacts Type Pack Weight AC2 AC3 AC3 AC1 380V 400V 415V kW 500V kW 660V 690V kW 400V A 690V A NO NC Suitable Overload Relay 1 1 F...

Page 5: ...ide Distinc Number according to DIN EN 50012 Contactor K1 Type NO NC Contactor K2 Type NO NC 3 pole With Screw Terminals 01 J73KN AM 11V 1 1 J73KN AM 11X 1 1 Wiring Diagrams Contacts suitable for Elec...

Page 6: ...6 16 Rated operational power of three phase resistive loads 230V kW 6 3 6 3 50 60Hz cos 1 240V kW 6 7 6 7 400V kW 11 11 415V kW 11 5 11 5 Minimum cross section of conductor at load with Ie Ith mm 2 5...

Page 7: ...0 Short circuit protection for contactors without thermal overload relay Coordination type 1 according to IEC 947 4 1 Contact welding without hazard of persons max fuse size gL gG A 40 40 Coordination...

Page 8: ...0 15 0 25 Resistance to shock according to IEC 68 2 27 Shock time 20ms sine wave AC operated NO g 5 5 NC g 5 5 DC operated NO g 8 8 NC g 6 6 1 Suitable at 690V for earthed neutral systems overvoltage...

Page 9: ...0 4 0 4 0 4 220V A 0 1 0 1 0 1 Maximum ambient temperature Operation open C 40 to 60 90 3 enclosed C 40 to 40 Storage C 40 to 90 Short circuit protection short circuit current 1kA contact welding not...

Page 10: ...e when suppressor units for voltage peak protection are used Varistor RC units Diode units Mini Motor Contactors Data according to IEC 947 5 1 VDE 0660 EN 60947 5 1 Auxiliary Contacts Type J7KNA 09 J7...

Page 11: ...ontactor J7KNA 11 Dimensions AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA 09 J7KNA 12 J73KN A Reversing Contactors J7KNA 09 01 R J7KNA 12 01 R J7KNA 09 01 R J7TKN A J7KNA 12...

Page 12: ...rest of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into oun...