![Omron HEM907KIT Instruction Manual Download Page 15](http://html1.mh-extra.com/html/omron/hem907kit/hem907kit_instruction-manual_741742015.webp)
14
How to Apply the Cuff
The c
u
ff of OMRO
N
Digital A
u
tomatic Blood Press
u
re Monitor HEM-907 plays an important role of
collecting the information on
b
lood
v
essels. Please
w
rap the c
u
ff correctly according to the
proced
u
re.
1. Select the c
u
ff according to the arm
circ
u
mference of the patient.
• Use c
u
ff that is s
u
ita
b
le for the size of the patient's
arm.
• If a c
u
ff not s
u
ita
b
le for the arm size is
u
sed,
b
lood
press
u
re may not
b
e meas
u
red correctly.
• Check the follo
w
ing
b
efore
w
rapping the c
u
ff.
1) The
b
ladder is sec
u
rely installed in the c
u
ff.
2) The
b
ladder is not t
w
isted inside the c
u
ff.
3) The
b
ladder t
ub
e is protr
u
ding from the c
u
ff as
sho
w
n in the Fig
u
re on the right.
2. Connect the air t
ub
e sec
u
rely.
• When connecting the air t
ub
e to the main
u
nit,
sec
u
rely connect the air pl
u
g to the
b
ase of the air
connector.
• Sec
u
rely connect the air t
ub
e and the c
u
ff/
b
ladder
set
b
y rotating them as sho
w
n in the Fig
u
re.
• If yo
u
connect the attached 1 m air t
ub
e, the air t
ub
e
can
b
e
u
sed
w
ith the entire length of 1.2 m.
3. Prepare the patient to
b
e ready to
w
rap the c
u
ff.
• Wrap the c
u
ff directly on the arm as a r
u
le.
• If the c
u
ff is
w
rapped o
v
er a thick cloth or
b
y rolling
u
p a jacket or a shirt,
b
lood press
u
re may not
b
e
meas
u
red correctly.
Warnin
g
Do not
w
rap the c
u
ff o
v
er the arm to
w
hich
intra
v
eno
u
s injection or transf
u
sion is
b
eing
cond
u
cted.
• Intra
v
eno
u
s injection or transf
u
sion
w
ill
b
e
impossi
b
le.
Do not erroneo
u
sly connect the air t
ub
e or the
c
u
ff to the t
ub
e of other eq
u
ipment connected
to intracorporeal organ.
• Air may get into
b
lood
v
essel.
Arm circ
u
mference
N
ame of the c
u
ff
17 - 22 cm
C
u
ff /
b
ladder set S (option)
22 - 32 cm
C
u
ff /
b
ladder set M
32 - 42 cm
C
u
ff /
b
ladder set L (option)
General advice
• Do not inflate the c
u
ff
b
efore it is
w
rapped o
v
er the
arm.
• Do not
u
se torn c
u
ff.
IND
EX
ART.
RANGE
MIN
MAX
32~42
cm(13
"~17"
)
REF HEM
-CL19
RANGE
MIN
MAX
IND
EX
ART.
22~32c
m(9"
~13"
)
REF
HEM
-CR19
ART.
RANGE
MIN
MAX
IND
EX
REF HE
M-CS19
17~22cm
(7"~ 9"
)
TUBE
TUBE
TUBE
ART.
TUBE
Cuff
Air tube
Air connector
Air plug
Cuff side
Air tube side
Extract the air tube from
.
TUBE
Enlarged figure of
the circled part
Know Your Unit
Preparations before Measurement
HEM-907-C3_D_M.fm Page 14 Wednesday, July 4, 2018 12:11 PM