background image

Instruction manual

page   1

Gebrauchsanweisung Seite 

17

Gebruiksaanwijzing pagina 

33

Mode d’emploi 

page 49

Manuale de instructone 

pagina 65

Manual de instrucciones 

pagina 81

RX-3

Blood Pressure Monitor

IM-HEM-640-E-01-08/08

1628088-1E

28070122-06 RX-3 Cover  14-08-2008  15:48  Pagina 1

Summary of Contents for HEM-640-E

Page 1: ...sung Seite 17 Gebruiksaanwijzing pagina 33 Mode d emploi page 49 Manuale de instructone pagina 65 Manual de instrucciones pagina 81 RX 3 Blood Pressure Monitor IM HEM 640 E 01 08 08 1628088 1E 28070122 06 RX 3 Cover 14 08 2008 15 48 Pagina 1 ...

Page 2: ... and pulse simply and quickly from the wrist without the use of an inflation bulb or stethoscope The measurement values are stored in the memory of the OMRON RX 3 The OMRON RX 3 fits wrist circumferences from 13 5 to 19 5 cm 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 1 ...

Page 3: ... twice a day before breakfast after work Do not measure your blood pressure while you are in a vehicle Always measure on the same wrist Wrap the wrist cuff around your wrist before start of measurement Caution Operating temperature between 10 C and 40 C Operating environment must be free from excessive vibrations shocks magnetic fields electrical noise etc Stay out of sunlight during measuring Kee...

Page 4: ...3 RX 3 English Overview A D E C B A Display B Wrist Cuff C Memory Recall button D On Off button E Battery Compartment 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 3 ...

Page 5: ... the battery compartment Insert batteries 1 Open the battery compartment 2 Insert two batteries in the battery compartment Caution Use two identical 1 5V alkaline batteries type AAA LR03 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 4 ...

Page 6: ...your sleeve avoid constricting the blood flow 2 Put the monitor on the inner side of your wrist 3 Hold the end of the wrist cuff and wrap it around your wrist Caution Be sure the wrist cuff fits closely do not pinch your arm Note attach the monitor upside down for reliable measurement at your right wrist 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 5 ...

Page 7: ... H Diastolic blood pressure in mmHg J Memory display values in memory K Memory position 1 to 28 L Inflation wrist cuff inflates and measurement starts M Deflation wrist cuff deflates and measurement finishes N Battery exhausted batteries are weak exhausted P Pulse heartbeats per minute Operation SYSmmHg MEMORY PULSE min DI AmmHg C D F H G P J N M L K 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina ...

Page 8: ...feet flat on the floor and put your arm against the hard case Caution The OMRON RX 3 should always be at heart height during measurement Usage of the hard case assures the right position of the OMRON RX 3 2 Press On Off button to start measurement The OMRON RX 3 measures during inflation Caution Sit still do not move do not speak and do not touch the OMRON RX 3 28070106 RX 3 GB 01 16 14 08 2008 15...

Page 9: ... alternately blood pressures and heartbeats Read display 2 Note values in your personal blood pressure pass 3 Press On Off button to turn off power SYSmmHg MEMORY PULSE min DI AmmHg SYSmmHg MEMORY PULSE min DI AmmHg SYSmmHg MEMORY PULSE min DI AmmHg 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 8 ...

Page 10: ...ory Recall button for latest and previous values Press On Off button to turn off power Note Display shows alternately blood pressures and heartbeats SYSmmHg MEMORY PULSE min DI AmmHg K SYSmmHg MEMORY PULSE min DI AmmHg 1 Press Memory Recall button to turn on power Note Display shows alternately blood pressures and heartbeats 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 9 ...

Page 11: ... 2 Press Memory Recall button and simultaneously On Off button to erase memory Caution All stored values will be erased Press On Off button to turn off power SYSmmHg MEMORY PULSE min DI AmmHg SYSmmHg MEMORY PULSE min DI AmmHg 28070106 RX 3 GB 01 16 14 08 2008 15 36 Pagina 10 ...

Page 12: ...s causes and rectifications Fault Cause Rectification Correct reading not possible Movement sound vibration Wait for at least three minutes to weak pulse repeat measurement Display Low voltage Batteries weak exhausted Fit two new identical 1 5V alkaline empty batteries type AAA LR03 Inexplicable values Wrong working method Follow instructions repeat measurement 28070106 RX 3 GB 01 16 14 08 2008 15...

Page 13: ...onsult your OMRON retail outlet or OMRON distributor as mentioned on the packaging Replace batteries Remove the battery out of the battery compartment and insert two new identical 1 5V alkaline batteries type AAA LR03 batteries Spare parts Due to high company quality standards OMRON considers the main unit as a non serviceable part because the need for proper calibration after replacement of high ...

Page 14: ...160 g ex including batteries Outer dimensions Approx 47 mm W x 71 mm H x 79 mm D Wrist circumference Approx 13 5 cm to 19 5 cm Accessories Instruction manual guarantee card blood pressure pass 2 alkaline batteries storage box Note Subject to technical modification without prior notice Type B 0197 Manufacturer OMRON HEALTHCARE CO LTD Japan EU representative OMRON HEALTHCARE EUROPE B V Kruisweg 577 ...

Page 15: ... pressure The World Health Organisation WHO and the International Society of Hypertension ISH developed the blood pressure classification This classification is based on the blood pressure values measured while sitting on a chair in the outpatient department of a hospital According to the blood pressure classification by the WHO ISH General information about blood pressure Optimal blood pressure t...

Page 16: ...ssible causes of abnormally high blood pressure Overweight High cholesterol level Smoking Excessive alcohol consumption Stress and emotional upset Excessive consumption of salt Lack of physical exercise Genetic hereditary predisposition Underlying illnesses such as kidney disorders or endocrine disturbance Blood pressure measurement Measuring your blood pressure daily enables you to recognize high...

Page 17: ...level by reducing the calories and fat in your diet Cut down on animal fats and eat more fruit and vegetables Reduce the consumption of alcohol Reduce the intake of salt the German League for Combating High Blood Pressure recommends six grams of salt per day i e one teaspoon on average Stop smoking Take regular exercise Monitor your blood pressure Example fluctuation within a day male 35 years old...

Page 18: ...t Zone Dalian 116600 China OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG United Kingdom OMRON Medizintechnik Handelsgesellschaft mbH John Deere Str 81a 68163 Mannheim Germany www omron medizintechnik de OMRON SANTÉ FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France Made in China Manufacturer EU representative Production facility Subsidiary EC REP 28070122 06 RX ...

Reviews: