background image

Instruction Manual

Fat Loss MONITOR

with Scale

Model

HBF-400

HBF-400-IM  2/20/06  5:50 PM  Page 1

Summary of Contents for HBF-400

Page 1: ...Instruction Manual Fat Loss MONITOR with Scale Model HBF 400...

Page 2: ..._____________________________________________ 10 Changing Personal Data ______________________________________________________ 12 How to Take a Measurement ____________________________________________...

Page 3: ...the results of the last measurement taken for each personal ID number Your HBF 400 comes with the following components Main Unit Instruction Manual 4 AA Batteries Read all the information in the inst...

Page 4: ...after taking a bath or shower Do not use the unit on slippery surfaces such as tile floors or wet floors Should battery fluid leak and contact your eyes or skin immediately rinse with plenty of clean...

Page 5: ...t percentage by the Bioelectrical Impedance BI method What is the Bioelectrical Impedance Method Muscles blood vessels and bones are body tissues having a high water content that conduct electricity e...

Page 6: ...menopausal women People having swelling Recommended Measurement Times Understanding the normal changes in your body fat percentage can help you in preventing or reducing obesity Being aware of the ti...

Page 7: ...al of Clinical Nutrition Vol 72 Sept 2000 The above index refers to the values for obesity judgment proposed by WHO the World Health Organization K BMI classification Displays 0 with 12 levels of Bar...

Page 8: ...ndicator Display Mode Indicator GUEST Indicator Low Battery Indicator Measurement Results Measurement Progress Body fat percentage and BMI Classification Bar Personal Profile Number Height Indicator G...

Page 9: ...icator When the Low Battery Indicator appears on the display screen remove all four worn batteries Replace with four new batteries at the same time NOTE New batteries will last for approximately one y...

Page 10: ...ol blinks on the display followed by the 0 0 lb symbol as illustrated below NOTE Wait for the 0 0 lb symbol to appear before proceeding 2 Select USER or GUEST as your personal data option A USER with...

Page 11: ...is set The default value 5 3 for height blinks on the display SETTING THE HEIGHT Set the height between 3 4 and 6 6 3 4 1 Press the UP button or DOWN button to change the height The value changes in i...

Page 12: ...setting The CAL symbol blinks on the display followed by the 0 0 lb symbol You can take a measurement DELETING PERSONAL PROFILES All the personal data stored in a Personal Profile Number can be delete...

Page 13: ...ersonal Profile Number Press the USER button Select your Personal Profile Number How to view previous measurement results before taking a measurement After selecting your Personal Profile Number press...

Page 14: ...foot and the soles of your feet are clean and dry Position your feet on the electrodes as shown in the illustration to the right Make sure each of your heels is positioned on a heel electrode Stand wi...

Page 15: ...monitor off Press the Power Switch Measuring Weight Only 1 Turn the monitor ON Press the Power Switch The CAL symbol blinks on the display followed by the 0 0 lb symbol as illustrated below 2 Step ont...

Page 16: ...MI values are outside the measurement range Check the settings entered for your personal data Change the settings if needed Retake the measurement If this error occurs again and the settings are corre...

Page 17: ...fer to Battery Installation on page 9 To keep your Fat Loss MONITOR with Scale in the best condition and protect the unit from damage follow the directions below Clean the unit with a soft dry cloth A...

Page 18: ...your Personal Profile Number Press the GUEST MEMORY button Enter your Personal Data Refer to page 10 Setting Personal Data 3 Press the SET button NOTE Wait for the 0 0 lb symbol to appear before proce...

Page 19: ...y one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the product and the receiver Connect the product into an outlet on a circuit differen...

Page 20: ...tter with your name address phone number and description of the specific problem Pack the product carefully to prevent damage in transit Because of possible loss in transit we recommend insuring the p...

Page 21: ...ation is 20 to 79 years old Set Ranges Height 3 4 to 6 6 3 4 Age 10 to 80 years old Gender Male Female Power Supply 4 AA batteries Battery Life Approximately 1 year when used four times a day Operatin...

Page 22: ...22 TRACK YOUR PROGRESS Date Time Weight Body Fat BMI...

Page 23: ...23 NOTES...

Page 24: ...Distributed by OMRON HEALTHCARE INC 1200 Lakeside Drive Bannockburn Illinois 60015 www omronhealthcare com Made in China 2006 Omron Healthcare Inc HBF 400INST Rev 9042754 1...

Reviews: