H7E
@-N@P
23
Specifications
■
General
■
Ratings
Note:
ON/OFF ratio 1:1
■
Characteristics
Note: 1.
Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)
2.
The power supply terminals of the H7E
@
-N
@
P are considered as 3-VDC control terminals.
Item
Total Counter
Time Counter
H7EC-NP
H7EC-NLP
H7ET-NP
Operating mode
Up type
Mounting method
Direct mounting on PC Board or mounting on 28-pin socket
Reset
External reset, Power-OFF reset
Number of digits
8
7
Time range
---
0.0h to 999999.9h
Max. counting speed
1 kHz
30 Hz
---
Count/Timer input
No-voltage input
Display
7-segment LCD (character height: 8.6 mm)
Case color
Transparent
Approved standard
UL863, CSA C22.2 No.14
Item
H7EC-NP
H7EC-NLP
H7ET-NP
Supply voltage
3 VDC (2.7 to 3.3 VDC)
Count/Timer input
No voltage input
Maximum short-circuit impedance: 10 k
Ω
max.
Short-circuit residual voltage: 0.5 V max.
Minimum open impedance: 750 k
Ω
min.
Reset input
Max. counting speed (see note)
1 kHz: Minimum signal width of 0.5 ms
30 Hz: Minimum signal width of 16.7 ms
---
Minimum signal input width
---
1 s
Reset system
External reset: Minimum signal width of 20 ms
Power-OFF reset: Minimum power OFF time of 500 ms
Ambient temperature
Operating: –10
°
C to 55
°
C (with no condensation or icing)
Storage:
–25
°
C to 65
°
C (with no condensation or icing)
Ambient humidity
Operating: 25% to 85%
Item
H7EC-NP
H7EC-NLP
H7ET-NP
Time accuracy
---
±
100 ppm (25
°
C)
Noise immunity
Square-wave noise generated by noise simulator (pulse width: 100 ns/1
μ
s, 1-ns rise)
±
500 V (Between count or timer input terminals/Between reset terminals)
Static immunity
±
8 kV (malfunction)
Vibration resistance
Malfunction:0.15-mm single amplitude at 10 to 55 Hz for 10 min each in 3 directions
Destruction:0.375-mm single amplitude at 10 to 55 Hz for 2 hrs each in 3 directions
Shock resistance
Malfunction:200 m/s
2
3 times each in 6 directions
Destruction:300 m/s
2
3 times each in 6 directions
EMC
(EMI)
EN61326-1 (See note 1.)
Emission Enclosure:
EN55011 Group 1 class B
(EMS)
EN61326-1 (See note 1.)
Immunity ESD:
EN61000-4-2: 4-kV contact discharge (level 2)
8-kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves:
EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:
EN61000-4-3: 10 V/m (900 MHz
±
5 MHz) (level 3)
Immunity Conducted Disturbance (see note):EN61000-4-6: 10 V (0.15 to 80 MHz) (level 3)
Immunity Burst (see note 2.):
EN61000-4-4: 2-kV I/O signal line (level 4)
Weight
Approx. 20 g
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from
Downloaded from