H3Y

H3Y

3

Engineering Data

H3Y-2

Switching operations (x 10   )

3

Load current (A)

H3Y-2

H3Y-4

Switching operations (x 10   )

3

Load current (A)

Switching operations (x 10   )

3

Load current (A)

H3Y-4

Switching operations (x 10   )

3

Load current (A)

250 VAC, cos

φ

 = 1

24 VDC, cos

φ

 = 1

250 VAC, cos

φ

 = 0.4

24 VDC, L/R = 7 ms

250 VAC, cos

φ

 = 1

24 VDC, cos

φ

 = 1

250 VAC, cos

φ

 = 0.4

24 VDC, L/R = 7 ms

Reference: A maximum current of 0.6 A can be

switched at 125 VDC (cos

φ

 = 1).

Maximum current of 0.2 A can be
switched if L/R is 7 ms. In both
cases, a life of 100,000 operations
can be expected.
The minimum applicable load is
1 mA at 5 VDC (P reference value).

Reference: A maximum current of 0.5 A can be

switched at 125 VDC (cos

φ

 = 1).

Maximum current of 0.2 A can be
switched if L/R is 7 ms. In both
cases, a life of 100,000 operations
can be expected.
The minimum applicable load is
1 mA at 1 VDC (P reference value).

Operation

 Timing Chart

H3Y-2

H3Y-4

Time limit contact

NC (9-1, 12-4)

Time limit contact NC

(9-1, 10-2, 11-3, 12-4)

Summary of Contents for H3Y -

Page 1: ...cket Time limit operation lf tti DPDT 0 1 s to 30 min 110 VAC H3Y 2 e o e a o self resetting 0 s o 30 220 VAC 3 24 VDC 4PDT 110 VAC H3Y 4 220 VAC 3 24 VDC Note Specify the model number supply voltage and rated time when ordering Ex H3Y 2 110 VAC 1 s Rated time Supply voltage Accessories Track mounted socket see note Back connecting socket ac ou ed soc e see o e Solder terminal Wire wrap terminal P...

Page 2: ...del see note 1 500 VAC 50 60 Hz for 1 min between different pole contacts 4 pole model 1 000 VAC 50 60 Hz for 1 min between non continuous contacts Vibration resistance Destruction 10 to 55 Hz with 1 0 mm double amplitude Malfunction 10 to 55 Hz with 1 0 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100G Malfunction 100 m s2 approx 10G Ambient temperature Operating 10 C to 50 ...

Page 3: ...of 0 6 A can be switched at 125 VDC cosφ 1 Maximum current of 0 2 A can be switched if L R is 7 ms In both cases a life of 100 000 operations can be expected The minimum applicable load is 1 mA at 5 VDC P reference value Reference A maximum current of 0 5 A can be switched at 125 VDC cosφ 1 Maximum current of 0 2 A can be switched if L R is 7 ms In both cases a life of 100 000 operations can be ex...

Page 4: ...ny one of these sockets replace j with 08 or 14 Terminal Arrangement Top View Track Mounting Front Connecting Sockets PYF08A Eight M3 8 sems Two 4 2 5 mounting holes Two 4 5 dia M4 or M3 Mounting Holes 6 72 max 23 max 30 max 16 5 35 4 3 4 4 6 59 0 3 15 0 2 PYFjA 90 5 86 6 H3Y Series Terminal Arrangement Top View PYF14A Mounting Holes Fourteen M3 8 sems Two 4 2 5 mounting holes Two 4 5 dia M4 or M3...

Page 5: ...14 14 13 20 8 Two 3 5 dia 30 max 4 42 3 32 2 22 1 12 8 44 7 34 6 24 5 14 41 12 31 11 21 10 11 9 A1 13 A2 14 A2 14 66 5 max PYF 14A N 29 5 max 42 32 22 12 44 34 24 14 41 31 21 11 A2 A2 A1 PYF14A N Terminal Arrangement Mounting Holes for Surface Mounting PYF08A E 31 max 72 max 23 max Top View PYF14A E 31 max 72 max 29 5 max Top View Eight M3 8 sems Two 4 2 5 mounting holes Two 4 5 dia M4 or M3 Two 4...

Page 6: ...te Note With PYjQN 2 dimension should read 20 max and dimension 36 5 max 29 5 max 25 5 max 24 max 0 3 2 7 7 7 20 max 2 6 2 7 29 5 max 41 5 max see note 25 max 24 max 22 max H3Y Series PYj PYj 02 PYjQN 2 29 5 max 25 5 max 22 max 0 3 2 7 4 3 16 5 max 2 PY08 02 PY14 02 59 3 21 4 0 2 0 Terminal Arrangement Bottom View Terminal Arrangement Bottom View PY08QN PY08QN 2 PY14QN PY14QN 2 PY08 PY14 25 8 0 2 ...

Page 7: ... 2 PY14QN 2 PYP 1 PYP 18 Note PYP 18 may be cut to any desired length PYP 1 Two 3 4 dia holes PYP 18 Relay Hold down Clips Y92H 3 for PYFjA Socket Y92H 4 for PYj Socket Mounting Track PFP 100N PFP 50N see note 1 End Plate PFP M 1000 500 See note 2 Note 1 Meets DIN EN50022 2 This dimension applies to PFP 50N Spacer PFP S ...

Page 8: ... contacts different from each other in polarity may become short circuited Correct Incorrect Use the following safety circuit when building a self holding or self resetting circuit with the H3Y and an auxiliary relay such as an MY Relay in combination H3Y Auxiliary relay MY Relay Do not use the H3Y in places where there is excessive dust corro sive gas or direct sunlight Do not mount more than one...

Reviews: