• Please do not connect EtherCAT Junction unit with OMRON position control  

   unit, Model CJ1W-NC

81/ 

82. 

EtherCAT Junction Slave 

Model GX-JC03/JC06 

Instruction Manual 

Thank you for purchasing an OMRON EtherCAT Junction slave,  

Model GX-JC03/JC06.  

To secure safe operation, please be sure to read this manual. Keep this 

instruction manual in a safe location and be sure that it is readily available  

to your final users of the product.  

©OMRON Corporation 2011 All Rights Reserved. 

2104229-8B

● 

Meanings of Signal Words 

● 

Warning Symbols 

Precautions for Safe Use 

Precautions for Correct Use 

Indicates a potentially hazardous situation which, if not  

avoided, could result in death or serious injury.  

Additionally,  there may be severe property damage. 

Warning 

Indicates a potentially hazardous situation which, if not  

avoided, may result in minor or moderate injury, or 

property damage. 

Caution 

Warning 

Do not attempt to disassemble this unit and do not touch the interior  

of any Unit while the power is being supplied. In addition, do not turn  

on electricity in the state that founded a cover. Doing so may result in  

Do not attempt to disassemble, repair, or modify this unit. Any attempt 

 to do so may result in malfunction, fire, or electric shock. 

Take a fail-safe countermeasures by the customer to secure safety in  

case of an 

abnormal signal casued by broken signal line and  

Not doing so may result in serious accidents. 

Pay careful attention to the pola/-) when the DC power supply.  

A wrong connection may cause malfunction of the system.  

• Install correctly according to instructions in the instruction manual. Improper  

installation of the Unit may result in malfunction. 

• Do not drop any Unit or subject any Unit to excessive shock or vibration.  

Otherwise, Unit failure or malfunction may occur. 

• Do not operate the control system in the following locations: 

• Locations subject to direct sunlight. 

• Locations subject to temperatures or humidity outside the range specified in 

the specifications. 

• Locations subject to condensation as the result of severe changes in  

• Locations subject to corrosive or flammable gases. 

• Locations subject to dust (especially iron dust) or salts. 

• Locations subject to exposure to water, oil, acid, or chemicals. 

• Locations subject to shock or vibration. 

• 

Take appropriate and sufficient countermeasures when installing systems in 

the following locations: 

• Locations subject to static electricity or other forms of noise. 

• Locations subject to strong electromagnetic fields. 

• Locations subject to possible exposure to radioactivity. 

• Locations close to power lines. 

• Wire all connections correctly according to instructions in the instruction  

• Use the correct wiring materials to wire the Units. 

• Confirm voltage specifications when wiring communications, the power supply. 

  Incorrect wiring may result in malfunction. 

• 

Turn off the power of Controller and all slaves before wiring the communication 

• 

Take appropriate measures to ensure that the specified power with the rated  

voltage and frequency is supplied. Be particularly careful in places where the 

power supply is unstable. An incorrect power supply may result in malfunction. 

• Check the user program for proper execution before actually running it on the 

Unit. Not checking the program may result in unexpected operation. 

• Check all wiring and switch settings to be sure they are correct. 

OMRON Corporation 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Specifications subject to change without notice. 

Caution 

• 

When transporting this product, use special packing boxes and protect it   

from being to excessive vibration or impact during transportation. 

• Mount the Units securely using DIN track. 

• 

Make sure that the terminal blocks, communications cables, and other items  

with locking  devices are properly locked into place. Improper locking may  

• Do not extend connection distances or the number of connected nodes  

beyond the ranges given in the EtherCAT specifications. 

• Do not allow foreign matter to enter this product. 

• Always use the specified communications cables and connectors. 

• Confirm the polarity of all terminals before wiring them. 

• 

Always use the power supply voltage specified in the instruction manual. An  

incorrect voltage may result in malfunction or burning. 

• Do not bend cables past their natural bending radius or pull on cables. 

• Observe the following precautions when wiring the communications cable. 

• Separate the communications cables from the power lines or high-tension 

• Do not bend the communications cables past their natural bending radius. 

  

• Do not pull on the communications cables. 

   

• Do not place heavy objects on top of the communications cables. 

  

• Always lay communications cable inside ducts. 

Emergency stop circuits, interlock circuits, limit circuits, and similar  

  

safe measures  must be externally provided to Slave Unit.  

Do not apply the voltage/current outside the specified range to this  

product. It may cause a malfunction or fire. 

• Be sure to ground when installing the unit. 

Notice to Users of EtherCAT Junction Slave in the USA and  

Precautions for Complicance with 

UL Standatds and CSA Standards 

Please use the following installation information instead of the general 

information in the instruction manuals in order to use the product under  

certified conditions of UL and CSA when the product is installed in the USA or  

Canada. These conditions are required by NFPA 70, National Electrical Code 

in the USA and the Canadian Electrical Code, Part in Canada and may vary  

from information given in the product manuals or safety precautions. 

■ Wiring for Unit power connector

The external power supply must be an isolated DC source. It must be equipped 

with an over-current protection with current limitation in 4A.

■ Applicable wire size for Unit power source terminal block.

Type

Solid/Strand

Wire size

AWG16-24

Strip lengh

9mm

Do not use ferrule terminals. Insert the strand or solid wire directly into the 

holes on the terminal block.

■ Direction for installation

Vertical only 

■ Compliance with Class I Division 2 Hazardous Location:

Input and output wiring must be in accordance with Class In Div.2 wiring methods 

and in accordance with the authority having jurisdiction.

1. This equipment is suitable for use in Class I, Div.2, Group A, B, C, D or 

    Non-Hazardous Locations Only.

2. WARNING : Explosion Hazard - Substitution of Components may Impair 

    Suitability for Class I, Div.2.

3. WARNING : Explosion Hazard - Do not Disconnect Equipment Unless Power 

    Has Been Switched off or the Area Is Known to Be Non-Hazardous.

4. This device is open-type and is required to be installed in an enclosure suitable 

    for the environment and can only be accessed with the use of a tool or key.

1. Cet equipement convient a l'utilisation dans des emplacements de Classe I, 

    Division 2, Groupes A, B, C, D, ou ne convient qu'a l'utilisation dans des endroits 

    non dangereux.

2. AVERTISSEMENT : Risque d'explosion - La substitution de composants peut 

    rendre ce materiel inacceptable pour les emplacements de Classe I, Division 2.

3. AVERTISSEMENT : Risque d'explosion - Avant de debrancher l'equipement, 

    couper le courant ou s'assurer que l'emplacement est designe non dangereux.

4. Ce dispositif est de type ouvert et doit etre installe dans un coffret adapte a 

    l'environnement et auquel on ne pourra acceder uniquement au moyen d'un 

    outil ou d'une cle.

Conformance to EC Directives 

• 

This product is EMC-compliant when assembled in PLC system . To ensure 

   the EC Directive conformance of customer’s machinery or equipment in  

   which the product is incorporated, be sure to observe the following 

   precautions. 

   1. This product is defined as an in-panel device and must be installed within  

       a control panel. 

   2. Reinforced insulation or double insulation must be used for the DC power 

       supply connected to the DC power supply unit, communication unit, and 

       I/O unit. 

   3. This product complies with the common emission standard (EN61131-2, 

       EN61000-6-4) with regard to EMI. For the radiated emission requirement  

       (10-m regulations), in particular, please note that the actual emission  

       varies depending on the configuration of the control panel to be used, the 

       connected devices, and wiring methods. Therefore, the customer must 

       confirm the EC Directive conformance of the overall machinery or  

       equipment by themselves, even if this EC conforming product is used. 

• 

This is a class A product. In residential areas it may cause radio  

   interference, in which case the user maybe required to take adequate  

   measures to reduce interference. 

• 

This product is EMC-compliant when the recommend power supply(S8**) 

  is used 

 

SUI T ABILIT Y FOR USE 

OM R O N shall not be res p on s i b le f o r con f o r mity with a n y  standa r d s , 

co d e s , or regulat io ns t hat app l y t o t he co m b i n at i o n o f  pro d ucts in th e 

custome r ’ s a p p licat i on or u s e of the produc t s . 

T a k e all n e ces s a r y steps to dete r mine the su i t ability of the  pro d uct 

f o r the system s , machi ne s , and eq u i p ment with whi c h it will b e us e d . 

Please kn o w a n d obse r v e a l l p r ohi b iti o n s of use  app l ic a b le to t h e 

pro d uct s . 
NEVER USE T H E P R ODUC T S FOR AN A P PLIC A T ION IN V O L VING 

SERIOUS RISK T O LIFE OR P R OPE R T Y  WITHOU T E N SURING 

TH A T THE SYSTEM AS A WHOLE HAS BEEN DESIGNED T O 

ADDRESS THE RISK S , AND TH A T THE OM R O N P R ODUCTS ARE 

P R OPER L Y R A T ED AND INS T ALLED FOR THE INTENDED USE 

WITHIN THE O VERAL L  E Q UIPMEN T OR SYSTEM . 
See al s o pro d u ct catalogs f o r W a r r anty a n d L i mitations of Lia b ilit y . 

+

 

-

 

24V  DC

 

Unit Power Supply

Isolated source 

Over-current protection (Current limitation: 4A)

 

 

Minimum Wire size

24 AWG

Ampere rating of protection

2A

22 AWG

3A

20 AWG

4A

Fax: (65) 6835-2711 

Tel: (65) 6835-3011 

Singapore 119967 

(Lobby 2), Alexandra Technopark, 

No.438A Alexandra Road # 05-05/08 

OMRON ASIA PACIFIC PTE.LTD 

OMRON ELECTRONICS LLC 

Fax: (31) 2356-81-388. 

 

Tel: (31)2356-81-300 

 

The Netherlands 

 

Wegalaan 67-69-2132 JD Hoofddorp 

 

 

OMRON EUROPE B.V. 

 

 

Regional Headquarter 

 

 

Contact: www.ia.omron.com 

 

 

Tokyo, JAPAN 

Industrial Automation Company 

One Commerce Drive Schaumburg, 

IL 60173-5302 U.S.A 

Tel: (1) 847-843-7900 

Fax: (1) 847-843-7787 
OMRON (CHINA) CO., LTD. 

200120, China 

Pu Dong New Area, Shanghai, 

200 Yin Cheng Zhong Road, 

Room 2211, Bank of China Tower, 

Fax: (86) 21-5037-2200 

Tel: (86) 21-5037-2222 

EtherCAT     is registered trademark and patented technology, licensed by  

Beckhoff Automation GmbH, Germany.  

(R) 

electric shock. 

momentary power interruption.   

result in malfunction. 

temperature. 

• Please pull out the connector inserted in Port 4,5,6 at first when all the ports 

  of GX-JC06 is used. 

Each Part Name 

■ 

 LED 

Extinction: Power OFF 

Lit: Power ON 

Green 

PWR 

L/A 

Green 

Extinction: No connect or No link when 

connection 

Lit: Link, No data communication 

Blinking: Link, Data communication 

  

  

Indication LED 

PWR: Power Supply 

LAN Port 

3ports: GX-JC03 

6ports: GX-JC06 

  Power Supply Connector 

  

  

  

+24V 

FG 

GND 

FK-MCP1.5/3-ST-3.81 

L/A LED: Link, ACT 

  

  

■ LAN Cable 

Product name

Comment

Twist-pair cable

(Cable with connectors

below are also allowed)

100BASE-TX (Category 5 or higher)

Double-shield (aluminum tape + braided shielding)

RJ45 connector

Category 5 or higher Shielded

Specification 

Power supply Voltage
Consumption  

Electric Power 
Ambient operating 

temperature 
Ambient operating 

humidity 
Storage temperature 
Storage humidity 

DC 20.4V~28.8V 

GX-JC03: 80mA;  GX-JC06: 170mA 

-10 to 55 

°C 

  

-25 to 65 

°C 

  

25% to 85% (with no condensation)

 

  

25% to 85% (with no condensation)

 

  

  

■ 

 LAN PORT 

Name on Tool

Name on Unit

1/IN

Detail 

IN 

X2 

X3 

X4 

X5 

X6 

Port1 (IN port) 

Port2 (OUT port) 

Port3 (OUT port) 

Port4 (OUT port) 

Port5 (OUT port) 

Port6 (OUT  port) 

Dimension 

GX-JC03:  25mm×78mm×90mm; 

GX-JC06:  48mm×78mm×90mm  

Troubleshooting 

[PWR]

indicator

Without 

     power supply, 

     power supply 

     disconnection

Internal power

    supply is broken.

Contents

OFF

Power 

supply 

error

[L/A]

LED

Cause

Measures

OFF

OFF

ON

Without 

establishing 

Link

Communication 

     cable comes off,

    disconnection 

    and short.

Slave’s hardware

     is broken.

Host master 

    hasn’t been started

Check the power 

     supply unitand

     cables. 

    

Replace the slave.

GX-JC03 

DIN Rail

GX-JC06

DIN Rail

Check the connection 

     of communication 

     cable,

     Change the  

     communication cable    

 Replace the slave

 Check status of the 

      host master.

• Fail-safe measures must be taken by the customer to ensure safety in the  

event of  incorrect, missing, or abnormal signals caused by broken signal  

lines, momentary power interruptions, or other causes. 

• Default node setting is 0, please set the node by tool. 

 

• Always separate cables by at least 5 mm to prevent unstable operation due to 

  interference. Do not bundle cables. 

Safety Precautions 

manual

 

• Install external breakers and take other safety measures against  

short-circuiting in 

external wiring. Insufficient safety measures against  

short-circuiting may result in burning. 

Reviews: