No.13S064-13
26/55
STC-CMC2MPOE / STC-CMB2MPOE / STC-CMB2MPOE-IR /
STC-CMC4MPOE / STC-CMB4MPOE / STC-CMB4MPOE-IR Product Specifications and User’s Guide
Exposure Timing with the Positive Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
Exposure Timing with the Negative Polarity Trigger Signal
Note 1: The trigger signal will be removed by the filtering if the pulse width of the input trigger signal is less than 30 CLK.
Please input a trigger signal with more than 31 CLK pulse width.
Note 2: The exposure will start 105 CLK after the rising edge of the trigger signal.
Input Trigger signal
Exposure time
Exposure time: T1' = T1 + 127 CLK
T1
30 CLK
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
60 useconds
T1
75 CLK
Input Trigger signal
Exposure time
Exposure time:: T1' = T1 + 127 CLK
T1
Filtering *Note.1
Trigger signal
(With Photocoupler delay
Less than
15 useconds
T1
30 CLK
75 CLK