background image

G7L

G7L

14

Precautions

Refer to page NO TAG for general precautions.

Handling

!

To preserve performance, do not drop or otherwise subject the
Power Relay to shock.

!

The case is not designed to be removed during normal handling
and operation. Doing so may affect performance.

!

Use the Power Relay in a dry environment free from excessive
dust, SO

2

, H

2

S, or organic gas.

!

Do not allow a voltage greater than the maximum allowable coil
voltage to be applied continuously.

!

Do not use the Power Relay outside of specified voltages and
currents.

!

Do not allow the ambient operating temperature to exceed the
specified limit.

Installation

!

Although there are not specific limits on the installation site, it
should be as dry and dust-free as possible.

!

PCB Terminal-equipped Relays weigh approximately 100 g. Be
sure that the PCB is strong enough to support them. We
recommend dual-side through-hole PCBs to reduce solder
cracking from heat stress.

!

Quick-connect terminals can be connected to Faston receptacle
#250 and positive-lock connectors.

!

Allow suitable slack on leads when wiring, and do not subject the
terminals to excessive force.

Cleaning PCB Terminals

!

PCB terminals have flux-tight construction which prevents flux
from penetrating into the Relay base housing, e.g., due to
capillary action up the terminals when Relay is soldered onto the
PCB. This type of Relay cannot be immersed for cleaning.

Connecting

!

Refer to the following table when connecting a wire with a
crimp-style terminal to the G7L.

Terminals

Screw terminals

Front-connecting

Socket

Coil

8

5.8

5

M3.5

8

6.5

5.3

M3.5

Contact

5.5

6.5

9.2

M4

7

5.5

9.2

M4

Rated Current Flow

When using B-series (screw) products, the rated current from the
screw terminals (M4) should be 20 A or less according to jet stan-
dard (electrical appliance and material control law of Japan).

Operating Coil

!

As a rule, either a DC battery or a DC power supply with a
maximum of 5% ripple must be used for the operating voltage for
DC Relays. Before using a rectified AC supply, confirm that the
ripple is not greater than 5%. Ripple greater than this can lead to
variations in the operating and reset voltages.

As excessive ripple can generate pulses, the insertion of a
smoothing capacitor is recommended as shown below.

E max.:

Max. ripple

E min.:

Min. ripple

E mean: Mean DC value

Smoothing
capacitor

Relay

Ripple

E min. E max.

E mean

DC fraction

% of ripple =

x 100

E max. -- E min.

E mean

!

When driving a transistor, check the leakage current and
connect a bleeder resistor if necessary.

DIN Track Mounting Adapter and

Front-connecting Socket

DIN Track Mounting

!

Use a DIN-conforming 50-cm track or 1-m track (both are sold
separately) for mounting a number of G7L Relays.
Cut and shorten the track to an appropriate length it if the
required track length is less than 50 cm.

!

The DIN Track Mounting Adapter and Front-connecting Socket
can be mounted on the G7L with just one hand and dismounted
with ease by using a screwdriver.

!

To support the G7L mounted on a DIN Track Mounting Adapter
or Front-connecting Socket, use the PFP-M End Plate. Put the
End Plate onto the DIN Track Mounting Adapter or
Front-connecting Socket so that the surface mark of the End
Plate faces upwards. Then tighten the screw of the End Plate
securely with a screwdriver.

Screw Mounting

!

Screw-mount the DIN Track Mounting Adapter or Front-connect-
ing Socket securely after opening screw mounting holes on
them.

!

When cutting or opening holes on the panel after the
Front-connecting Socket is mounted, take proper measures so
that the cutting chips will not fall onto the Relay terminals. When
cutting or opening holes on the upper part of the panel, mask the
Front-connecting Socket properly with a cover.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.

To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. J055-E1-3A

Summary of Contents for G7L -

Page 1: ...nnect screw and PCB terminals and DIN track mounting available RCE Ordering Information Mounting type Contact form Quick connect terminals Screw terminals PCB terminals E bracket SPST NO G7L 1A T G7L 1A B DPST NO G7L 2A T G7L 2A B E bracket with test button SPST NO G7L 1A TJ G7L 1A BJ DPST NO G7L 2A TJ G7L 2A BJ Upper bracket SPST NO G7L 1A TUB G7L 1A BUB DPST NO G7L 2A TUB G7L 2A BUB Upper bracke...

Page 2: ... G7L 1A BUBJ G7L 2A B G7L 2A BJ G7L 2A BUB G7L 2A BUBJ Cover P7LF C Model Number Legend G7L 1 2 3 4 5 1 Contact Form 1A SPST NO 2A DPST NO 2 Terminal Shape T Quick connect terminals P PCB terminals B Screw terminals 3 Mounting Construction Blank E bracket UB Upper bracket 4 Special Functions Blank Standard mode J With test button 5 Rated Coil Voltage AC 12 24 50 100 to 120 200 to 240 DC 6 12 24 48...

Page 3: ... 1 Theratedcurrentandcoilresistancearemeasuredatacoiltemperatureof23 Cwithtolerances of 15 20 forACratedcurrent and 15 for DC coil resistance 2 Performance characteristic data are measured at a coil temperature of 23 C 3 indicates AC and indicates DC IEC417 publications Contact Ratings Model G7L 1A Tj G7L 1A Bj G7L 2A Tj G7L 2A Bj G7L 1A P G7L 2A P Resistive load cos 1 Inductive load cos 0 4 Resis...

Page 4: ... Impulse withstand voltage 10 000 V between coil and contact with 1 2 x 50 s impulse wave Vibration resistance Destruction 10 to 55 Hz 1 5 mm double amplitude Malfunction 10 to 55 Hz 1 5 mm double amplitude Shock resistance Destruction 1 000 m s2 Malfunction 100 m s2 Life expectancy Mechanical 1 000 000 operations min at 1 800 operations hr Electrical 100 000 operations min at 1 800 operations hr ...

Page 5: ...120 VAC T 1 5 HP 120 VAC 6 x 103 3 HP 277 VAC 100 x 103 CSA 6 x 103 20 FLA 120 LRA 120 VAC 17 FLA 102 LRA 265 VAC 30 x 103 TV 10 120 VAC 25 x 103 G7L 2A P DPST NO 20 A 277 VAC RES 20 A 277 VAC GEN 20 A 120 VAC GEN 100 x 103 1 3 kW 120 VAC T 1 HP 120 VAC 6 x 103 2 HP 277 VAC 20 FLA 120 LRA 120 VAC 100 x 103 20 FLA 120 LRA 120 VAC 17 FLA 102 LRA 265 VAC 30 x 103 TV 8 120 VAC 25 x 103 TÜV File No R90...

Page 6: ...7L 2A B Maximum Switching Power Switching voltage V Life Expectancy Switching current A G7L 1A P G7L 2A P Maximum Switching Power Switching voltage V Life Expectancy Switching current A Switching current A Switching current A AC resistive load AC inductive load cos 0 4 AC resistive load AC inductive load cos 0 4 220 VAC resistive load 220 VAC resistive load 220 VAC inductive load cos 0 4 220 VAC i...

Page 7: ...J with Test Button G7L 2A TJ with Test Button Two 4 5 dia hole or M4 tapped holes Quick connect Terminals with DIN Track Mounting Adapter Note 1 The DIN Track Mounting Adapter and DIN tracks are sold separately 2 The DIN Track Mounting Adapter can be track mounted or screw mounted G7L 1A T Terminal Arrangement Internal Connections Top View Mounting Holes 0 1 4 6 40 0 1 Two M4 or 4 5 dia holes PFP ...

Page 8: ... D 0 1 2 4 6 8 Quick connect Terminals with Front connecting Socket Note 1 The Front connecting Socket and DIN tracks are sold separately 2 The Front connecting Socket can be track mounted or screw mounted G7L 1A T Terminal Arrangement Internal Connections Top View Mounting Holes 40 0 1 Two M4 or 4 5 dia holes 0 1 4 6 G7L 2A T 0 1 2 4 6 8 65 max 61 5 max 51 5 max 5 G7L P7LF 06 55 5 max 65 max 61 5...

Page 9: ... M4 screws for contact PFP jN G7L P7LF 06 Two M3 5 screws for coil Four M4 screws for contact 55 5 max 65 max 61 5 max 51 5 max 5 2 PFP jN G7L P7LF 06 Quick connect Terminals with Upper Bracket G7L 1A TUB G7L 2A TUB Terminal Arrangement Internal Connections Top View Terminal Arrangement Internal Connections Top View Mounting Holes Two 4 5 dia hole or M4 tapped holes G7L 1A TUBJ with Test Button Te...

Page 10: ...sold separately G7L 1A B G7L 2A B G7L 1A BJ with Test Button G7L 2A BJ with Test Button Terminal Arrangement Internal Connections Top View Mounting Holes Two M3 5 screws for coil Two M3 5 screws for coil Two M3 5 screws for coil Two M3 5 screws for coil Two M4 screws for contact Four M4 screws for contact Two M4 screws for contact Four M4 screws for contact Two 4 5 dia hole or M4 tapped holes ...

Page 11: ...les 0 1 4 6 0 1 2 4 6 8 55 5 max 69 max 65 5 max 51 5 max 5 PFP jN G7L P7LF D 55 5 max 69 max 65 5 max 51 5 max 5 PFP jN G7L P7LF D G7L 1A BJ with Test Button G7L 2A BJ with Test Button 0 1 4 6 0 1 2 4 6 8 55 5 max 69 max 65 5 max 51 5 max 5 PFP jN G7L P7LF D 2 55 5 max 69 max 65 5 max 51 5 max 5 2 PFP jN G7L P7LF D Screw Terminals with Upper Bracket G7L 1A BUB Terminal Arrangement Internal Connec...

Page 12: ...ernal Connections Top View Two M3 5 screws for coil Four M4 screws for contact Two M3 5 screws for coil Two M3 5 screws for coil Two M4 screws for contact Four M4 screws for contact Two 4 5 dia hole or M4 tapped holes PCB Terminals with PCB Mounting G7L 1A P G7L 2A P Terminal Arrangement Internal Connections Top View Terminal Arrangement Internal Connections Top View Mounting Holes Bottom View Mou...

Page 13: ...M4 or 4 5 dia holes 40 0 1 Two M4 or 4 5 dia holes 26 24 17 8 40 46 30 24 7 50 5 5 10 19 7 4 4 3 Two 4 5 dia holes 25 Two M3 5 screws for coil 40 0 1 55 5 max 46 max 51 5 max 5 35 2 max 9 2 Four M4 screws for contact 8 55 5 max 51 5 max 5 14 5 40 0 1 Mounting Holes Bottom View 34 5 max 50 5 max 1 6 max 40 0 1 Two M4 or 4 5 dia holes Mounting Holes Bottom View Internal Coil Circuit DC Operating Coi...

Page 14: ...ating Coil As a rule either a DC battery or a DC power supply with a maximum of 5 ripple must be used for the operating voltagefor DC Relays Before using a rectified AC supply confirm that the ripple is not greater than 5 Ripple greater than this can lead to variations in the operating and reset voltages As excessive ripple can generate pulses the insertion of a smoothing capacitor is recommended ...