3 Specifications
3 - 34
OMNUC G5-series (Pulse-train Input Type) AC Servomotors and Servo Drives User’s Manual
Connecting the Servo Drive with a computer via the USB connector enables operations such as
parameter setting and changing, control status monitoring, alarm status and history checking, and
parameter saving and loading.
Precautions for Correct Use
Precautions for Correct Use
Use a commercially available USB cable that is shielded, equipped with a ferrite core for noise
immunity, and supports USB2.0.
The Mini B type USB cable can be used.
3-1-11 USB Connector Specifications (CN7)
Pin
No.
Symbol
Name
Function and interface
1
VBUS
USB signal terminal
Used for computer communications
2
D–
3
D+
4
–
Reserved for
manufacturer use
Do not connect.
5
SENGND
Signal ground
Signal ground