Solid State Relays
G3NA
3
Specifications
■
Ratings
Input (at an Ambient Temperature of 25
°
C)
Note: 1.
The input impedance is measured at the maximum value of the rated supply voltage (for example, with the model rated at 100 to 120 VAC,
the input impedance is measured at 120 VAC).
2.
With constant current input circuit system.
3.
Refer to
Temperature Characteristics (for Must Operate Voltage and Must Release Voltage)
in
Engineering Data
for further details.
Output
Note: 1.
The load current varies depending on the ambient temperature. Refer to
Load Current vs. Ambient Temperature
under
Engineering Data
.
2.
When an OMRON Heat Sink (refer to
Options
) or a heat sink of the specified size is used.
Model
Rated voltage
Operating voltage
Impedance
(See note 1.)
Voltage level
Must operate voltage
Must release voltage
G3NA-2
@@
B-UTU
5 to 24 VDC
4 to 32 VDC
15 mA max. (See note 2.) 4 VDC max.
1 VDC min.
100 to 120 VAC
75 to 132 VAC
36 k
Ω±
20%
75 VAC max. (See note 3.) 20 VAC min. (See note 3.)
200 to 240 VAC
150 to 264 VAC
72 k
Ω±
20%
150 VAC max. (See note 3.) 40 VAC min. (See note 3.)
G3NA-4
@@
B-UTU
5 to 24 VDC
4 to 32 VDC
7 mA max. (See note 2.)
4 VDC max.
1 VDC min.
100 to 240 VAC
75 to 264 VAC
72 k
Ω±
20%
75 VAC max.
20 VAC min.
G3NA-275B-UTU
G3NA-290B-UTU
G3NA-475B-UTU
G3NA-490B-UTU
G3NA-D210B-UTU
5 to 24 VDC
4 to 32 VDC
15 mA max. (See note 2.) 4 VDC max.
1 VDC min.
100 to 240 VAC
75 to 264 VAC
72 k
Ω±
20%
75 VAC max.
20 VAC min.
Model
Applicable load
Rated load voltage Load voltage range
Load current (See note 1.)
Inrush current
With heat sink
(See note 2.)
Without heat sink
G3NA-205B-UTU
24 to 240 VAC
19 to 264 VAC
0.1 to 5 A (at 40
°
C)
0.1 to 3 A (at 40
°
C)
60 A (60 Hz, 1 cycle)
G3NA-210B-UTU
0.1 to 10 A (at 40
°
C)
0.1 to 4 A (at 40
°
C)
150 A (60 Hz, 1 cycle)
G3NA-410B-UTU
200 to 480 VAC
180 to 528 VAC
0.2 to 10 A (at 40
°
C)
0.2 to 4 A (at 40
°
C)
G3NA-220B-UTU
24 to 240 VAC
19 to 264 VAC
0.1 to 20 A (at 40
°
C)
0.1 to 4 A (at 40
°
C)
220 A (60 Hz, 1 cycle)
G3NA-425B-UTU
200 to 480 VAC
180 to 528 VAC
0.2 to 25 A (at 40
°
C)
0.2 to 4 A (at 40
°
C)
G3NA-240B-UTU
24 to 240 VAC
19 to 264 VAC
0.1 to 40 A (at 40
°
C)
0.1 to 6 A (at 40
°
C)
440 A (60 Hz, 1 cycle)
G3NA-250B-UTU
24 to 240 VAC
19 to 264 VAC
0.1 to 50 A (at 40
°
C)
0.1 to 6 A (at 40
°
C)
G3NA-450B-UTU
200 to 480 VAC
180 to 528 VAC
0.2 to 50 A (at 40
°
C)
0.2 to 6 A (at 40
°
C)
G3NA-275B-UTU
24 to 240 VAC
19 to 264 VAC
1 to 75 A (at 40
°
C)
1 to 7 A (at 40
°
C)
800 A (60 Hz, 1 cycle)
G3NA-475B-UTU
200 to 480 VAC
180 to 528 VAC
1 to 75 A (at 40
°
C)
1 to 7 A (at 40
°
C)
800 A (60 Hz, 1 cycle)
G3NA-290B-UTU
24 to 240 VAC
19 to 264 VAC
1 to 90 A (at 40
°
C)
1 to 7 A (at 40
°
C)
1,000 A (60 Hz, 1 cycle)
G3NA-490B-UTU
200 to 480 VAC
180 to 528 VAC
1 to 90 A (at 40
°
C)
1 to 7 A (at 40
°
C)
1,000 A (60 Hz, 1 cycle)
G3NA-D210B-UTU
5 to 200 VDC
4 to 220 VDC
0.1 to 10 A (at 40
°
C)
0.1 to 4 A (at 40
°
C)
20 A (10 ms)
Summary of Contents for G3NA
Page 15: ...Solid State Relays G3NA 15...