background image

5

Solid State Relay

G3M

Dimensions

Note:

All units are in millimeters unless otherwise indicated.

PCB Dimensions

(Bottom View)

G3M-102PL-US(-4), G3M-202P(L)-US(-4)

G3M-203P(L)(-4)

G3M-205P(L)(-4)

Terminal Arrangement

(Bottom View)

Precautions

Protective Element

No overvoltage absorption element is built in. Therefore, if the G3M

is connected to an inductive load, be sure to connect the overvol-

tage absorption element.

Summary of Contents for G3M

Page 1: ...2 mm Yes No 2 A at 100 to 240 VAC 2 A t 75 t 264 VAC 5 VDC G3M 202P US 2 A at 75 to 264 VAC 12 VDC 24 VDC 3 A at 100 to 240 VAC 3 A t 75 t 264 VAC 5 VDC G3M 203P 3 A at 75 to 264 VAC 12 VDC 24 VDC 5 A at 100 to 240 VAC 5 A at 75 to 264 VAC 5 VDC G3M 205P 5 A at 75 to 264 VAC 12 VDC 24VDC No 2 A at 100 to 120 VAC 2 A t 75 t 132 VAC 5 VDC G3M 102PL US 2 A at 75 to 132 VAC 12 VDC 24 VDC 2 A at 100 to...

Page 2: ...0 VAC 3 A t 75 t 264 VAC 5 VDC G3M 203PL 4 3 A at 75 to 264 VAC 12 VDC 24 VDC 5 A at 100 to 240 VAC 5 A t 75 t 264 VAC 5 VDC G3M 205PL 4 5 A at 75 to 264 VAC 12 VDC 24 VDC Note 1 TÜV marking is available with UTU in place of US on the part number 2 VDE versions available Contact your local OMRON representative Specifications J RATINGS Input Rated voltage Operating voltage Impedance Voltage levels ...

Page 3: ...ion Approved standards UL508 File No E64562 CSA C22 2 No 0 No 14 File No LR35535 TÜV R9551055 EN60950 Ambient humidity Operating 45 to 85 Weight Approx 15 g Approx 25 g J APPROVALS UL File No E64562 CSA File No LR35535 Input Voltage SSR Type Load Rating 5 12 24 VDC With Suffixes 102 and US or UTU 2 A 125 VAC Resistive 250 W 125 VAC Tungsten 2 A FLA 12 A LRA 125 VAC With Suffixes 202 and US 2 A 250...

Page 4: ...e Ambient Inrush Current Immunity Non repetitive Reduce the current to 1 2 or less if the G3M is in repetitive operation Load Current vs Ambient Temperature Close Mounting G3M 205 5 A Load D Thirty Relays are soldered to the PCB at each given spacing D Continuous power ...

Page 5: ... Dimensions Bottom View G3M 102PL US 4 G3M 202P L US 4 G3M 203P L 4 G3M 205P L 4 Terminal Arrangement Bottom View Precautions Protective Element No overvoltage absorption element is built in Therefore if the G3M is connected to an inductive load be sure to connect the overvol tage absorption element ...

Page 6: ...le use of any Product nor to imply that any use listed may be suitable for any Product a Outdoor use use involving potential chemical contamination or electrical interference b Use in consumer Products or any use in significant quantities c Energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations su...

Page 7: ... THE RISKS ANDTHATTHEOMRONPRODUCTISPROPERLYRATEDAND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIP MENT OR SYSTEM 2 ProgrammableProducts Sellershallnotberesponsiblefortheuser s pro gramming of a programmable product or any consequence thereof 3 Performance Data Performance data given in this publication is provided as a guide for the user in determining suitability and does not constitute...

Page 8: ...Suite B Schaumburg IL 60173 847 882 2288 01 07 Specifications subject to change without notice Complete Terms and Conditions of Sale for product purchase and use are on Omron s website at www omron com oei under the About Us tab in the Legal Matters section ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0 0352...