Controlling/Outputting through Parallel Communication
555
Clears measurement value by the parallel command
Output signal
Signal
Function
RUN
Turns ON when the controller is set to the RUN window. Turns OFF in the ADJUST window.
READY
Turns OFF when the command to clear the measurement value is being executed. Turns OFF as
long as the BUSY signal is turned ON.
BUSY
Turns ON when the measurement value is being cleared. The amount of time during which the
BUSY signal is turned ON is approximately 1 ms.
Input signal
Signal
Function
DI0 to 4
Turns the command OFF.
DI5
Turns the command OFF.
DI6
Turns the command ON.
DI7
This is the trigger signal to clear a measurement value.
After DI0 to 6 is set, turn DI7 ON after an interval over 1 ms.
BUSY signal is ON during execution of commands. After checking that the BUSY signal has turned
ON, turn DI7 OFF, and then turn DI0 to 6 OFF. Note, however, that the amount of time during which
the BUSY signal is turned ON is approximately 1 ms. If it cannot be recognized whether the BUSY
signal is turned ON or not by an external device, control the timing so that the DI7 signal is turned
ON for approximately 5 ms.
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......