FZ4 User's Manual
Controlling/Outputting through Serial Communication (Non-procedure)
443
Enter a delimiter at the end of commands.
In this manual, delimiters are expressed with "
".
Separate parameters with spaces. (Not required before delimiters.)
In the following cases, an error occurs. The system quits abnormally and the return values are returned
when an error occurs.
●
When non-existing commands are specified
●
The number of parameters is incorrect
●
The range of the parameters is incorrect
●
The content of parameters is incorrect
●
When action cannot be ended correctly with an action instruction command
Important
●
Commands can be input and measurement results can be output only when the Main screen is at the front and
the BUSY signal is OFF. When using only the serial commands (normal), the command execution completion
(BUSY OFF) can be recognized with the Fxxx method. Cannot receive commands when setting windows or the
Edit Flow windows are displayed (excluding Serial - Confirmation). On the Main screen, even if the screen is
switched to the Edit Flow window, etc., the data output after measurement will not be interrupted before all data
is output. Can not react to commands when windows other than the Main screen are displayed.
Command List (Non-procedure)
This section explains the input format for each command used in the serial normal method.
Commands are input with ASCII code.Both lowercase and uppercase letters can be used.
FZ4-11
/FZ4-H11
The configuration is as follows: USBDisk:E, USBDisk2:F, USBDisk3:G, and USBDisk4:H.
Execute command
Command
Abbreviation
Function
References
BRUNCHSTART BSU
Branches to the flow head (processing unit No. 0)
CLRMEAS
OFF
Clears all of the measurement values of the current scenes
CPYSCENE
CSD
Copies scene data
DATASAVE
OFF
Saves Scene group data in the controller's memory
DELSCENE
DSD
Deletes scene data
ECHO
EEC
Returns an arbitrary string as it is to the external device, which has
sent the string
IMAGEFIT
EIF
Returns the display position and display zoom ratio to their initial
values
IMAGESCROLL EIS
Moves the image display position in parallel the specified distance
IMAGEZOOM EIZ
Zooms in/out the image display by the specified zoom ratio
MEASURE
M
Perform measurement once
Start continuous measurement
Complete continuous measurement
MEASUREUNIT MTU
Executes measurement tests on specified units
MOVSCENE MSD
Moves scene data
REGIMAGE
RID
Registers specified image data as registered image
Loads the specified registered data as a measurement image
RESET
OFF
Restart the controller
TIMER
TMR
Executes the specified command string after a specified delay
Acesst 1.0 6251194
Summary of Contents for FZ4 Series
Page 1: ...User s Manual Cat No Z318 E1 02B Vision Sensor FZ4 Series...
Page 38: ...1 Before Operation 36 Setting Operation Mode FZ4 User s Manual 1 CPU 2 CPUs FZ4 11 H11 only...
Page 330: ...4 Using Tool 328 Remotely Operating the Controller Remote Operation FZ4 User s Manual...
Page 566: ......
Page 648: ...8 Appendixes 646 Manual Revision History FZ4 User s Manual...
Page 654: ...652 FZ4 User s Manual...
Page 655: ......