6
M
eth
od
s
fo
rC
on
ne
ctin
g
an
d
C
om
m
un
ica
tin
g
w
ith
E
xte
rn
al
D
ev
ice
s
FZ3 User's Manual
Controlling/Outputting through Serial Communication (Non-procedure)
147
Setting item
Set value
[Factory default]
Description
Address setting
●
Obtain an IP address automatically
●
[Use the following IP address]
Set the IP address of the controller.
When "Obtain an IP address
automatically" is selected, the IP
address of the controller will be
automatically obtained.
When "Use the following IP address"
is selected, set the IP address,
subnet mask, and the default
gateway address.
IP address
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.100]
Input the controller IP address.
Subnet mask
0.0.0.0 to
255.255.255.255
[255.255.255.0]
Input the subnet mask address.
Default gateway
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.110]
Input the default gateway address.
DNS server
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.5.1]
Input the DNS server address.
Input/Output setting
Input mode
[Normal]
This item cannot be changed.
Input form
[ASCII]
This item cannot be changed.
Output IP address
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[0.0.0.0]
Input the output destination IP
address.
Input/Output port No.
0 to 65535
[9600]
Set the port No. to use for data I/O
with the controller.
3.
Tap [OK].
The settings are confirmed and the Ethernet window closes.
Setting Communication Specifications (RS-232C/422 - Non-procedure)
Communication specifications such as communication speed and IP addresses are set for serial
interface (RS-232C/422 connection) communication.
Reference:
Setting Communication Specifications (Ethernet - Non-procedure) (p.145)