INSTRUCTION SHEET

Item

Picture element

14.4 W maximum. (12 VDC, 1.2 A maximum)

150 m/s

2

, 3 times each in 6 directions

(up/down, left/right, forward/backward)

Operating and storage : 35 to 85 %
(with no condensation)

10 to 150 Hz, half-amplitude : 0.35 mm
(maximum acceleration 50 m/s

2

)

10 times each in X,Y and Z directions for 8 min

Operating : 0 to 50 °C (with no icing or condensation)
Storage : -25 to 65 °C (with no icing or condensation)

No corrosive gases

Cover for camera :  Galvanized steel sheet metal
Case for camera :  Aluminum alloy
Case for lens : ABS
Cover for lens: Aluminum alloy
Mount base : Aluminum alloy

Approx. 500 g (including base).

AUTOMATIC FOCUS CAMERA FOR MODEL FZ VISUAL INSPECTION SYSTEM

Model

FZ-SZC15

PRECAUTIONS ON SAFETY

Main unit, instruction sheet (this manual) and hexagonal wrench

Make adjustment after disconnecting cable from the connector.
Loosen 3 screws located on the ring portion in the figure below using 
the attached hexagonal wrench. Turn the ring to adjust the direction. 
After adjustment, tighten the screws securely.

Connection

(1)Using the Camera cable FZ-VS

(sold separately),connect the 

connector on the back of the camera and the camera connector on 
Controller FZseries.

 The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, 

make sure that the end bearing a nameplate is connected to the 
Controller FZseries.

PRECAUTIONS FOR CORRECT USE

FZ-SZC15

To ensure safety, do not use this product for direct or indirect 
detection of data from human body.
Do not use this product as a sensing device for the protection 
of the human body.

WARNING

659 (H) x 494 (V)

1/3-inch interline color CCD
  (reading all pixels)

7.4 (µm) x 7.4 (µm)
Non-interlace mode
80.600Hz
39.336KHz
30.682MHz
12 lines to 480 lines
Internal synchronization
Digital, 10 bit
0dB to +13dB
1/10 to 1/50000s
Electrically driven magnification, 
focusing and iris

Zoom

Vari-focal
2.9mm to 14.9 mm, 
with tol/- 5% maximum
47.5 mm to 67.5 mm
480 TV minimum

Minimum: F3.4 (W-end) to F10.9 
(T-end)Range of W-end : 3.4 to 9.9

Magnification and focusing: 
10,000 times minimum
Iris: 20,000 times minimum

“MG-Wave”series by Moritex Co. 
product.

0.7A or less

FZ-SZC15

Item

IEC60529 IP20

Maximum 5 m(FZ-VS

Maximum 5 m(Model M-RCB40

by Moritex Co.product.)

(Unit: mm)

Indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury or in 
property damage.

CAUTION

Indicates a potentially hazardous situation which, if not 

avoided, will result in minor or moderate injury, or may 

result in serious injury or death. Additionally there may 

be significant property damage.

WARNING

Camera cable 
connector

Illumination connection
connector

Automatic focus camera 
FZ-SZC15

Nameplate

Camera cable 
FZ-VS

© OMRON Corporation 2007 All Rights Reserved.

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

OMRON Corporation

Suitability for Use

EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0  Fax: 49-7032-811-199

NORTH AMERICA
OMRON ELECTRONICS  LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A
Phone:1-847-843-7900 Telephone Consultation
1-800-55-OMRON    Fax : 1-847-843-7787

ASIA-PACIFIC
OMRON ASIA PACIFIC PTE LTD
83 Clemenceau Avenue,#11-01 UE Square,Singapore 239920
Phone : 65-6-835-3011 /Fax :65-6-835-2711

n

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

Camera 
specifications

Lens

Illumination

Effective pixels
Pixel size
Scanning method
Vertical frequency
Horizontal frequency
Pixel frequency
Number of lines to be read
Synchronization
Video output
Gain
Shutter speed
Operating system

Range of view

Working distance
Resolution
F value

Amperage rating

Connected illumination

Motor durability
(One(1) time is equivalent to
one (1) reciprocating motion)

Power consumption

Vibration
resistance

Shock resistance

Ambient
Temperature

Ambient
humidity

Ambient environment

Degree of protection

Material

Cable length

Cable length

Weight

50

134

40

 7

73.5

 45.2

59.4

66.5

25

45.2

20±0.1

46.9

28

10

10.5

72.2

68

30

93

89.5

M39X0.5

35

2-M4

 

DEPTH8

1/4-20UNC DEPTH8

Observe the following precautions to ensure safe use of the Camera.
1. Installation Site
Do not install the product in locations subjected to the following 
conditions:

 ·  Ambient temperature outside the rating
 ·  Rapid temperrature fluctuations (causing condensation)
 ·  Relative humidity outside the range of 35 to 85%
 ·  Presence of corrosive or flammable gases
 ·  Presence of dust, salt, or metallic particles
 ·  Direct vibration or shock
 · Reflection of intense light (such as other laser beams or electric 

arc-welding machines)

 ·  Direct sunlight or near heaters
 ·  Water, oil, or chemical fumes or spray
 ·  Strong magnetic or electric field
 ·  Near high-voltage equipment or power equipment

PRECAUTIONS FOR SAFE USE

2. Handing the Camera

 ·  Tighten all screws securely during installation.

3. Other Precautions

 ·  Do not use unspecified camera cable other than those that specified in 

this manual with the FZ controller. Connection with unspecified 
camera cable and/or strobe controller may malfunction at the worst 
case. 

 ·  When the connector on the back of the camera is not in use, be sure to 

cover the connector with the attached cap. 

 ·  Do not attempt to disassemble, repair, or modify the Camera.
 ·  If you notice any abnormality in the Camera, stop using it immediately, turn 

OFF the power supply, and contact your OMRON sales representative.

 ·  When disposing of the Camera, dispose of it as industrial waste.

Observe the following precautions to prevent the product from 
malfunctioning, becoming inoperable, or the performance and/or the 
device from being adversely affected:
1. Cable

 ·  Use a Camera Cable designed specifically for the Controller.
 · Be sure to turn off the power before connecting or disconnecting the 

cables.

2. Optical axis

 · The center of the optical axis may disperse by camera. When 

mounting a camera, always check the central position of video images 
with a monitor.

 ·  The center of CCD and the optical axis of the lens are aligned to the direction

of the camera at time of shipment. When the camera direction is changed,
the gap of center of optical axis may become large.

3. Maintenance

 ·  Do not use thinners, benzene, acetone, kerosene to clean the Camera.
 ·  Wipe off stubborn stains carefully with a piece of soft cloth that has 

been wetted with a trace quantity of alcohol. Scraches on the front 
Panel may cause errors.

 · If laege dust particles adhere to the front Panel of the Senser Head, 

use a blowerbrush (used to clean camera lenses) to blow them off. Do 
not blow the dust particles with your mouth.

4. Magnification

 · To avoid collisions of inside lens, maximum value for magnification 

setting varies in relation to the focusing value. If magnification is not 
sufficient, adjust the working distance.