background image

FQ

-D30/-D31

SAFETY PRECAUTIONS

Precautions for Safe Use

Precautions for Correct Use

 

Keys to Warning Symbols

 

Warning Symbols

Touch Finder for FQ

-S Smart Camera

FQ-CR Code Reader

FQ2-CH Optical Character Recognition Sensor

Indicates a potentially hazardous 

situation which, if not avoided, 

could result in death or serious 

injury. Additionally, there may be 

severe property damage.

The Touch Finder contains a lithium ion battery. There 

is danger of severe injury due to fire, explosion, or 

combustion. Never disassemble the Touch Finder, 

deform it by pressure, or heat it to 100°C or higher.

■ 

Dimensions

Always follow the rules below to ensure safety.

1. Installation environment

· Do not use in a location where there is flammable or explosive gas.

· To ensure safe operation and maintenance, install away from 

high-voltage equipment and power equipment.

· Install the unit so that the vents are not blocked.

2. Power and cable connections

· Use the specified power supply voltage.

· Use the specified size of crimp terminals for wiring connections. 

Do not connect wires that have been simply twisted together 

directly to the power supply or terminal block.

· Use a separate power supply. Do not share the power supply with 

other devices.

· Keep the power supply cable as short as possible.

· Do not use a voltage that exceeds the rated voltage, and do not use 

an AC power supply.

· Do not reverse the polarity of the power connection.

· Wire this product separately from the wiring of high-voltage wires 

and power wires. If wired together or in the same conduit, induction 

may occur and cause malfunctioning or damage.

· Supply power from a DC power supply for which measures have been 

applied to prevent high voltages (e.g., a safety overvoltage circuit).

· If UL certification is required for the overall system, use a UL Class 

II DC power supply.

· When using the FQ

-D31, do not use with the switching regulator 

and AC adapter (FQ-AC

) simultaneously connected.

· Tighten the mounting screws to the torque specified in these instructions.

· Use the specified size of crimp terminals.

· Always turn OFF the power supply before connecting or 

disconnecting cables or the power supply wiring.

· Turn OFF the power supply immediately if the battery leaks or 

produces an odor. Electrolyte leaked from the battery may ignite, 

possibly causing smoke, rupture, or fire.

· If, during usage, charging, or storage, the battery produces an odor, heats, 

becomes discolored, becomes misshapen, or exhibits any other unusual 

conditions, remove it and do not use it. Continuing to use such a battery 

may result in the battery heating, smoking, rupturing, or igniting.

3. Other Rules

· Do not use in safety circuits for atomic energy or that are critical 

for human life.

· Do not attempt to disassemble, deform by pressure, incinerate, 

repair, or modify this product.

· When disposing of the product, treat as industrial waste.

· Use the special sensor (FQ

-S, FQ-CR, FQ2-CH), battery (FQ-BAT1), 

and AC adapter (FQ-AC

). Using other than the specified devices 

may cause ignition, burning, malfunctioning, or failure.

· If you notice an abnormal condition, stop using the unit 

immediately, turn off the power, and consult your dealer.

· Do not drop or subject to shock.

· If the FQ

-D31 will be secured, remove the battery (FQ-BAT1).

If the rated temperature is exceeded with the battery inserted, the 

protective circuit may activate and stop the unit.

Observe the following to prevent failure, malfunctioning, and adverse 

effects on performance and the device.

1. Installation site

Do not install in the following locations:

· Locations where the ambient temperature exceeds the rated 

temperature range.

· Locations subject to sudden temperature changes (where 

condensation will form).

· Locations where the relative humidity is below or above 35 to 85% RH.

· Locations where there are corrosive or flammable gases.

· Locations where there is dust, salt, or iron powder.

· Locations where the device will be subject to direct vibration or 

shock.

· Locations where there is strong scattered light (laser light, arc 

welding light, ultraviolet light, etc.)

· Locations exposed to direct sunlight or next to a heater.

· Locations where there is splashing or spraying of water, oil, or chemicals.

· Locations where there is a strong electrical or magnetic field.

2. Power, connections, and wiring

· In environments subject to excessive noise, connect the specified 

ferrite core.

· When using a switching regulator, ground the FG pin of the 

switching regulator.

· If there are surges on your power line, connect a surge absorber as 

appropriate for your conditions of use.

· Before turning on the power after the wiring is completed, verify that 

the power is correct, that there are no incorrect connections such as a 

shorted load circuit, and that the load current is suitable. Incorrect 

wiring may cause damage and failures.

· In the following situations, do not turn off the power. Data being 

saved will be corrupted.

-Various data are being saved to the internal memory.

-Various data are being saved to an SD card.

· The LCD display panel is manufactured by precision technology; 

however, there may be a few faulty picture elements. This is due to 

the structure of the LCD panel and is not a product failure.

* Applicable to the FQ-D31 only.

* This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions.

*1 This is a guideline for the time required for the brightness to diminish to half the initial brightness at room temperature and humidity. No 

guarantee is implied. The life of the backlight is greatly affected by the ambient temperature and humidity. It will be shorter at lower or 

higher temperatures. 

*2 This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions.

*3 Charging is possible only when the power switch of the Touch Finder unit is OFF.

The following power supply is recommended (option)

Connecting the Power Supply

1. Loosen the two terminal screws using a Phillips screwdriver.

2. Attach crimp terminals to the power lines.

Secure the positive and negative lines as indicated using M3 

screws. Power supply tightening torque: 0.54 N

·

m

3. In environments where there is excessive noise, attach a ferrite core to 

the power supply cable (ZCAT1730-0730 from TDK or the equivalent).

1. Press the slider on the Touch Finder to the top.

2. Hook the clip at the top of the Touch Finder on to the DIN Track.

3. Press the Touch Finder onto the DIN Track until the bottom clip 

clicks into place.

Remove the power switch cover from the side of the unit, and 

switch the power switch to ON.

Removal Procedure

1. Pull down on the slider on the Touch Finder.

2. Lift the Touch Finder at the bottom and remove it from the 

DIN Track.

· Attach End Plates (sold separately) on the sides of the Touch 

Finder on the DIN Track.

· If other devices will be installed next to the Touch Finder on the 

same DIN Track, make sure that sufficient space is kept 

between the devices as indicated previously.

· Always hook the clip at the top of the Touch Finder on the DIN 

Track first. If the lower clip is hooked on first, the Touch Finder 

will not be mounted very securely.

1)Install the Touch Finder in the following orientation to allow sufficient heat 

dissipation.

2) Do not mount it in the following orientations.

3)To improve ventilation, leave space on both sides of the Touch Finder. The 

distance between the Touch Finder and other devices should be at least that 

shown in the following diagram.

• To prevent interference by noise, do not mount the Touch Finder on panels 

which contain high-voltage devices.

• To keep the level of noise from the surrounding environment to a minimum, 

install the Sensor and Touch Finder unit at least 200 mm away from power 

lines.

3. Settings for the Initial Startup

• When using the logging function or the date verification function in the 

OCR, set the date settings in the initial startup.

(Unit: mm)

WARNING

WARNING

■ 

Part Names and Functions

■ 

Mounting to DIN Track

■ 

Procedure for storing the touch pen

Remove the SD card cover from the top of the unit and insert 

the SD card.

FQ

-D30

FQ

-D31

FQ

-D30

FQ

-D31

■ 

Ratings/Performance

■ 

Performance specifications

15 mm min.

1)

3)

2)

15 mm min.

(5)

(1)

(12)

(2)

(6)

(7)

(4)

(3)

ON

OFF

(11)

(8)
(9)

(10)

24 VDC

1

2

3

3

2

1

8

11

11

95

44.5

70

52.9

20

35.5

85

35.5

1.1

27.9

12.1

19.2

17.3

3

15

13.5

23.8

14

27

The AC power connector is only on the FQ

-D31.

10

0.5

29

33

30

82

30

70

1.5 h

Number of sensors that can be recognized (switched): 32, number of sensors that can displayed on monitor: 8

(1)

(2)

(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)

■ 

Procedure for switching on the power switch

 Power connection

(when a switching regulator is connected)

■ 

Procedure for inserting an SD card

No.

Item

Item

Display

Operation 

interface

Touch 

screen

External 

interface
Battery

LCD

Display device

3.5-inch TFT color LCD
320 × 240

16,777,216

50,000 hours at 25°C

Provided  (a function for changing the time setting is available)

Resistance film

1,000,000 operations

100Base-TX/10Base-T
SDHC-compliant, Class 4 or higher recommended

Power indicator (color: green): POWER

Error indicator (color: red): ERROR

SD card access indicator (color: yellow):

SD ACCESS

Power indicator (color: green): POWER

Error indicator (color: red): ERROR

SD card access indicator (color: yellow): 

SD ACCESS

Charge indicator (color: orange): CHARGE

Provided

Pixels
Display colors

Screen saver

Method
Life expectancy*

2

Life expectancy*

1

Brightness 

adjustment

Backlight

Indicators

Ethernet
SD card slot

Number of connectable sensors

Current consumption

DC power connection: 0.2 A MAX

DC power connection: 0.2 A MAX   Charging battery: 0.4A MAX

Between all lead wires and case: 0.5 M

Ω

 (at 250 V)

Operating and storage: 35% to 85% (with no condensation) 

10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions 8 min each, 10 times

270 g max. (without battery or hand strap)
95 × 85 × 32.5 mm
Case: ABS
Touch Pen, Instruction Manual (This Instruction Sheet)

IEC 60529 IP20

150 m/s

2

 3 times each in 6 direction (up, down, right, left, forward, and backward)

No corrosive gas

Insulation resistance
Ambient temperature

Operating: 0 to 50°C

Storage: −25 to 65°C

(with no icing or condensation)

Operating: 0 to 50°C when mounted to DIN Track or panel

0 to 40°C when operated on a Battery

Storage: −25 to 65°C

(with no icing or condensation)

Ambient humidity
Ambient atmosphere
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection
Weight
Dimensions
Materials
Accessories

Continuous operation on Battery*

Name

Description
Lights green when power is supplied to the Touch Finder.
Lights red when an error occurs.
Lights yellow when an SD card is inserted. Flashes yellow when the SD card is being accessed.
Lights orange when the Battery is charging.

An SD card can be inserted.
The Battery is mounted behind this cover. Remove the cover when mounting or removing the Battery.
Used to turn the power supply to the Touch Finder ON and OFF.
The touch pen can be stored in here when it is not being used.
Used to operate the touch panel. Before using the Touch Finder, tie the touch pen strap to the strap holder.
Used to connect a DC power supply. 
Used to mount the Touch Finder to a DIN Track.
Used when connecting the Touch Finder to the Sensor with an Ethernet cable.
This is a holder for attaching the strap.
Used to connect the AC adapter.

This displays the setting menu, measurement results, and the image captured by the camera. The touch panel 

can be operated to configure camera and Touch Finder settings.

Operation 

indicators

LCD/touch panel

SD card slot
Battery cover*
Power supply switch
Touch pen holder
Touch pen
DC power supply connector
Slider
Ethernet port
Strap holder
AC power supply connector*

POWER
ERROR
SD ACCESS
CHARGE *

Allowable power voltage range

DC power connection: 20.4 to 26.4 VDC (including 

ripple)

When a DC power supply is connected: 

20. 4 V to 26.4 V DC (including ripple)

When the FQ-AC

 AC adapter (manufactured by Sino-

American Japan Co., Ltd) is connected: 

100 V to 240 V AC, 50/60 Hz

When a battery is connected: 

FQ-BAT1 battery pack (1 cell, 3.7 V)

Item
Recommended

Power Supply
External power supply 

terminal screws
Recommended power 

line wire size

Description
S8VS-01524 (24 VDC, 0.65 A)

M3.5 (tightening torque: 1.0 N

·

m)

AWG16 to AWG22 

(length of 5 m max.)

When you attach the ferrite core to the power 

supply cable, wrap the cable only one time.

Model

California regulations concerning perchlorate:

This product is a lithium battery that contains perchlorate, which 

is regulated by the State of California. Please comply with these 

regulations. For details see the following URL:

www.dtsc.ca.gov/hazardouswaste/perchlorate/

© OMRON Corporation  

2010-2016 

All Rights Reserved.

The following notice applies only to products that carry the CE mark:

Notice:

This is a class A product. In residential areas it may cause radio 

interference, in which case the user may be required to take adequate 

measures to reduce interference.

INSTRUCTION SHEET

Thank you for selecting OMRON product. This sheet pri-

marily describes precautions required in installing and

operating the product.

Before operating the product, read the sheet thoroughly to

acquire sufficient knowledge of the product. For your con-

venience, keep the sheet at your disposal.

Manufacturer:

  Omron Corporation,

  Shiokoji Horikawa, Shimogyo-ku,

  Kyoto 600-8530 JAPAN

 

TRACEABILITY INFORMATION:

Importer in EU:

  Omron Europe B.V.

  Wegalaan 67-69

  2132 JD Hoofddorp,

  The Netherlands

Charging function

Not available

Available*

3

Suitability for Use

s

Omron Companies shall not be responsible for conformity with any standards, 

codes or regulations which apply to the combination of the Product in the 

Buyer’s application or use of the Product. At Buyer’s request, Omron will 

provide applicable third party certification documents identifying ratings and 

limitations of use which apply to the Product. This information by itself is not 

sufficient for a complete determination of the suitability of the Product in 

combination with the end product, machine, system, or other application or 

use. Buyer shall be solely responsible for determining appropriateness of the 

particular Product with respect to Buyer’s application, product or system. 

Buyer shall take application responsibility in all cases. 

NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING 

SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 

SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 

AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND 

INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 

EQUIPMENT OR SYSTEM.

See also Product catalog for Warranty and Limitation of Liability.

Oct, 2014

D

OMRON Corporation

      Industrial Automation Company

 Contact:  www.ia.omron.com

Tokyo, JAPAN

OMRON ELECTRONICS LLC

2895 Greenspoint Parkway, Suite 200

Hoffman Estates, IL 60169 U.S.A.

Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road # 05-05/08 (Lobby 2), 

Alexandra Technopark, 

Singapore 119967

Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.

Room 2211, Bank of China Tower, 

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON EUROPE B.V.

Sensor Business Unit

Carl-Benz-Str. 4, D-71154 Nufringen, Germany

Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

Regional Headquarters

Reviews: