Section 1 Description
4
1-3 Ratings and Performance
Type
Item
F3SP-U2P
Number of light curtains
2 pairs max.
(NOTE1)
Supply voltage (Vs)
24 VDC ±10% (ripple p-p 10% max.)
Power consumption
8W max. (without muting lamp and sensors)
(NOTE1)
Response time
30ms max.
Applicable light curtain
OMRON make
F3SN series, F3SH series, F3SL series, F3SS series
Outputs
2 N.O contacts, 250VAC, 2.5 A max.
TEST input: N.C. contact switch
RESET input: N.O. contact switch
Inputs
Max. 4 mute sensor inputs: PNP transistor output type or N.O
contact output type.
Output indicator (Red/Green LED): Red lit when output OFF,
Green lit when output ON.
Input indicator (Green LED x4): Lit when 24V input.
Indicators
Status indicator (1digit):Indicates status of the F3SP
Test functions
Self-test (After power ON, and during operation)
External test (by TEST input)
Safety-related functions
Auto reset / manual reset
Muting function, Override function
Applicable Muting lamp
Incandescent lamp 24V, 3W to 7W
(NOTE1) (NOTE2)
Ambient temperature
During operation: -10 to 50°C (with no freezing)
During storage: -30 to 70°C
Ambient humidity
15 to 95% RH (with no condensation)
Degree of protection
IP20 (IEC60529)
Vibration resistance
10 to 55 Hz, double amplitude 0.7 mm, X, Y and Z directions
20 sweeps
Shock resistance
100 m/s
2
, X,Y and Z directions 1000 times
Weight
600g (control unit only)
Accessories
Instruction manual