3 System Components and Indicators
4
3 System Components and Indicators
Refer to “Figure 3-1” on page 5 for the location of the components and indicators listed below.
Table 3-1 System Components Identification
Note:
OSSD outputs must have a minimum load or the F3SL system will enter an alarm condition. For the pur-
pose of testing prior to final installation, this load can be supplied by a 10K ohm resistor (included in doc-
umentation kit). See Figure 7-1 for details.
Chart
#
Chart
#
C
RECEIVER
N
EMITTER
D
Upper Most/Lower Most Beam Indicators - Red
O
Status Indicator - Yellow
E
Removable End Cap. Access to configuration
switches
P
Emitter connections
F
Program button (must remove security screw)
10
Drain - Shield(Uninsulated) Wire
G
Channel Select or Floating Blanking Indicator -
Yellow
11
+24VDC - White Wire
H
Interlock or Fault Indicator - Yellow
12
0VDC(GND) - Brown Wire
I
Machine Stop Indicator - Red
Q
Synchronization Beam
J
Machine Run Indicator - Green
R
Optical axis
K
Receiver connections
S
Protective height (detection zone)
1
OSSD1 - Orange Wire (see note below)
2
0VDC(GND) - Brown Wire
3
Drain - Shield(Uninsulated) Wire
4
+24VDC - White Wire
5
Auxiliary Out - Violet Wire
6
MPCE - Pink Wire
7
Start - Gray Wire
8
OSSD2 - Yellow Wire (see note below)
L
Inside Receiver End Cap
B
Switch B
A
Switch A
M
Connector
☛