323
F3SG-SR
User’s Manual
Chapter
6
Wiring Exa
m
p
le
s
(f
or F3
SG-SR)
Input/Output Circuit and Applications
E
6-2-1-8. Pre-Reset Mode with EDM Unused
[Wiring Example]
When a functional earth is necessary, wire an earth cable according to the example in
Optical Synchronization and EDM Unused
. Also refer to
5-4-4. Functional Earth Connection
for more information.
F39-JG
C-L
F39-JG
C-D
24 VDC
Wiring for NPN *1
*6
24 VDC
IN
PLC *3
IN1
Safety controller
*4 *5
IN2
S1
Receiver
Emitter
OSSD 1 (Black)
OSSD 2 (White)
24V/0V (Brown)
OPERATING RANGE
SELECT INPUT (Yellow) *2
TEST (Black)
Not used (White)
24V/0V (Brown)
0V/24V (Blue)
0V/24V (Blue)
AUX (Red)
Not used (Pink)
PRE-RESET (Gray)
RESET/EDM
(Yellow) *3
S3
S2
*1. Reverse the polarity of the power supply when using in the NPN system. Select a PLC and a safety controller of PNP or NPN type according
to the system of your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
*3. When connecting to the PLC, the output mode must be changed with the SD Manager 3 according to your application. Refer to
for more information on setting this function by the SD Manager 3.
6-3. Connectable Safety Control Units
for more information.
*5. The safety controller and the F3SG-SR/PG must share the power supply or be connected to the common terminal of the power supply.
*6 This is the case for a PELV circuit.
*7 Set the function with the DIP Switches on the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform wiring
according to the wiring diagram.
Timing chart
Pre-reset switch (S3)
Reset switch (S2)
OSSD
T1
T3
T2
Beam state: Unblocked
Blocked
Unexpected beam
block
T1: Minimum pressing time of pre-reset switch. Configurable from 100 to 500 ms in 100-ms increments.
T2: Maximum permissible time from input of PRE-RESET signal to input of RESET signal. Configurable from 1 to 60 s in 1-s increments.
T3: Minimum pressing time of reset switch. Configurable from 100 to 500 ms in 100-ms increments.
S1: Test switch
S2: Lockout/interlock reset switch
S3: Pre-reset switch
PLC: Programmable logic controller (Used for monitoring only. NOT related to safety system.)
: Indicates a switch position.
Function
Setting
DIP switch
SD Manager 3
EDM
EDM Disabled (factory default setting)
EDM Disabled *7
[External device monitoring] : Disable *7
Pre-Reset *7
Pre-Reset
[Pre-Reset] : Enable
Operating Range Selection
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Long *7
[Operating Range Selection] : Long mode *7
Non-Muting system
Perform wiring according to the wiring diagram.
External Test used
Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact).
Optical Synchronization
Do not connect the COM(+) and COM(-) lines of the of emitter and receiver with each other.
㻟
㻻㻺
㻠
㻻㻺
㻡
㻻㻺
㻤
㻻㻺
Intelligent Tap
Needed
Summary of Contents for F3SG-SR Series
Page 1: ...Safety Light Curtain F3SG SR Series User s Manual Man No Z405I E3 01...
Page 18: ...xvi Introduction F3SG SR User s Manual...
Page 156: ...128 Chapter 2 IO Link F3SG SR User s Manual System Operation and Functions...
Page 340: ...312 Chapter 5 Cascade Connection F3SG SR User s Manual Wiring and Installation...
Page 368: ...340 Chapter 7 Maintenance Checklists F3SG SR User s Manual Checklists...
Page 398: ...370 Chapter 8 Revision History F3SG SR User s Manual Appendix...