Ratings and Specifications

LED Indicators

*1. The indicator of the emitter is illuminated only in the case the Wired Synchronization 

is enabled and is off in the case the Optical Synchronization is enabled.

*2. DIP switches is on the Intelligent Tap.
*3. Refer to the F3SG-SR User's Manual for more information on blinking patterns.
Note: In the SETTING state to make settings with the SD Manager 3, the TEST, 
LONG and CODE indicators on the emitter and the CFG, PNP and CODE indicators 
on the receiver blink. (TEST: Yellow, LONG/CODE: Green, CFG/PNP/CODE: Green)

  LED Indicators of the Receiver

CODE

or

C

ERR

or

E

OSSD

or

O

MAINT

or

M

PNP

or

P

CFG

or

F

SEQ

or

S

 LED Indicators of the Emitter

1

2

3

4

6

7

Scan code

Lockout

Operating range

Test

Top-beam-state (*1)

Bottom-beam-state (*1)

Green

OFF

Red

Green

OFF

Yellow

Blue

Blue

Code A is selected

Automatic interference prevention by wired synchronization being performed

LOCKOUT state. The indicator is illuminated in the emitter of 

another sensor segment than that having a lockout error 

(between the emitter and receiver in the Wired Synchronization)

Long Mode is selected

Short Mode is selected

---

The top beam is unblocked

The bottom beam is unblocked

---

LOCKOUT state. The indicator is illuminated in the emitter of a sensor segment having a lockout error

LOCKOUT state due to Operating range selection setting error

---

External Test is being performed

MUTING/OVERRIDE state, or LOCKOUT  state due to Other sensor error

MUTING/OVERRIDE state, or LOCKOUT  state due to DIP Switch setting error (*2)

Location

Indicator

Name

Color

Illuminated

Blinking

Location

Indicator

Name

Color

Illuminated

Blinking

TOP

BTM

CODE

or

C

ERR

or

E

LONG

or

L

TEST

or

T

1

2

3

4

5

6

7

9

10

Scan code

Lockout

ON/OFF

Maintenance

PNP/NPN mode

Configuration

Sequence

Top-beam- state

Bottom- beam-state 

Green

OFF

Red

Green

Red

Red

Orange

Green

OFF

Green

Yellow

Blue

Blue

Code A is selected

Automatic interference prevention by wired synchronization being performed

LOCKOUT state. The indicator is illuminated in the receiver of another sensor 

segment than that having a lockout error (when in cascade connection or 

between the emitter and receiver in the Wired Synchronization)

Safety outputs are in ON state

Safety outputs are in OFF state

LOCKOUT state due to a recoverable error 

Safety outputs are instantaneously turned OFF due to ambient light, 

vibration or noise. Or sequence error in Muting, Pre-Reset or PSDI

PNP is configured

NPN is configured

Fixed or Floating Blanking, Reduced Resolution, Warning Zone 

or Slow mode of Response Time Adjustment is enabled or

after the Muting zone is determined by the Dynamic Muting function.

INTERLOCK state

The top beam is unblocked

The bottom beam is unblocked

---

LOCKOUT state. The indicator is illuminated in the receiver of a sensor segment having 

a lockout error

---

LOCKOUT state due to Safety Output error, or error due to abnormal power supply or noise

LOCKOUT state due to a replacement- recommended error

Intelligent Tap is in the LOCKOUT state

Polarity of PNP is changed to NPN, or vice versa, during operation, and internal circuit is defective

---

TEACH-IN mode, zone measurement being performed by Dynamic Muting, or LOCKOUT 

state due to Blanking monitoring error, Configuration error or Parameter error

Sequence or sequence error in Muting, Pre-Reset or PSDI (*3) or Teach-in error

MUTING/OVERRIDE state, or LOCKOUT state due to Other sensor error

MUTING/OVERRIDE state, or LOCKOUT state due to DIP Switch setting error (*2)

TOP

BTM

Type 4: ±2.5° max.*, Type 2: ±5.0° max.*  (*Emitter and receiver at operating range of 3 m or greater)

Infrared LEDs, Wavelength: 870 nm

SELV/PELV 24 VDC±20% (ripple p-p 10% max.) 

See F3SG-SR/PG User's Manual for more information.

Two PNP or NPN transistor outputs (PNP or NPN is selectable by wiring of power supply.), Load current: 300 mA max., 

Residual voltage: 2 V max. (except for voltage drop due to cable extension), Capacitive load: 1 µF max., Inductive load: 2.2 H max.(*1 *2), 

Leakage current: 1 mA max.(PNP), 2 mA max.(NPN)(*3)

*1. The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.

*2. The load inductance is the maximum value when the safety output frequently repeats ON and OFF. When you use the safety output 

     at 4 Hz or less, the usable load inductance becomes larger.

*3. These values must be taken into consideration when connecting elements including a capacitive load such as a capacitor. 

One PNP or NPN transistor output (PNP or NPN is selectable by wiring of power supply.) Load current: 100 mA max., 

Residual voltage: 2 V max.(*)     *The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.

Light emission stops when connected to 24 V DC

ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *, OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *

Light emission stops when connected to 0 V DC

ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA), OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *

Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open

Short: 0 to 3 V (short circuit current: approx. 4.2 mA)

PNP  ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *, OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) * 

NPN  ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA), OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *

PNP  ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *, OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) * 

NPN  ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA), OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *

Output short-circuit protection

Optical synchronization by Scan Code: fixed    Wired synchronization: in up to 3 sets 

(See F3SG-SR/PG User's Manual for more information.) 

Interlock, External Device Monitoring (EDM) Pre-Reset, PSDI, Fixed blanking/Floating Blanking, Reduced Resolution, Muting/Override, 

Mutual Interference Prevention, PNP/NPN Selection, Response Time Adjustment  (See F3SG-SR/PG User's Manual for more information.)

Operating: -30 to 55 °C (non-icing), Storage: -30 to 70 °C

Operating: 35% to 85% (non-condensing), Storage: 35% to 95%

IEC 60529: IP65 and IP67, DIN40050-9: IP69K

In optical synchronization: 100 m max* between power supply and emitter and between power supply and receiver

In wired synchronization: 100 m max* between power supply and emitter, between power supply and receiver, and between emitter and receiver

* When the Intelligent Tap (F39-SGIT-IL3) is connected to the sensor, this applies in the case of the rated power supply of 24 VDC to 24 VDC +20%.

See F3SG-SR/PG User's Manual for more information.

Instruction Sheet, Quick Installation Manual, Troubleshooting Sticker

1.1×10

-8

 max. (IEC 61508) 

Opaque objects, 14-mm dia.

320 to 1,800 mm

0.3 to 8.0 m *

0.3 to 2.4 m *

Optical synch.: 8 to 18 ms, Wired synch.: 10 to 21 ms

Optical synch.: 40 to 90 ms, Wired synch.: 50 to 105 ms

Optical synch.: 16 to 36 ms, Wired synch.: 20 to 42 ms

Optical synch.: 80 to 180 ms, Wired synch.: 100 to 210 ms

Optical synch.: 32 to 72 ms, Wired synch.: 40 to 84 ms

Optical synch.: 160 to 360 ms, Wired synch.: 200 to 420 ms

Optical synch.: 64 to 144 ms, Wired synch.: 80 to 168 ms

Optical synch.: 320 to 720 ms, Wired synch.: 400 to 840 ms

Opaque objects, 25-mm dia.

320 to 1,840 mm

0.3 to 16.0 m

0.3 to 5.6 m

Optical synch.: 8 to 13 ms, Wired synch.: 10 to 17 ms

Optical synch.: 40 to 65 ms, Wired synch.: 50 to 85 ms

Optical synch.: 16 to 26 ms, Wired synch.: 20 to 34 ms

Optical synch.: 80 to 130 ms, Wired synch.: 100 to 170 ms

Optical synch.: 32 to 52 ms, Wired synch.: 40 to 68 ms

Optical synch.: 160 to 260 ms, Wired synch.: 200 to 340 ms

Optical synch.: 64 to 104 ms, Wired synch.: 80 to 136 ms

Optical synch.: 320 to 520 ms, Wired synch.: 400 to 680 ms

* When operating at an ambient temperature of -10 to -30°C, use the F3SG-SR with the operating range of 0.3 to 4.0 m in Long Mode and 0.3 to 1.2 m in Short Mode.

Model

F3SG-

SRB

□□□□

-14-K

F3SG-

SRB

□□□□

-25-K

Performance

Electrical

Functional

Environmental

Connections

Weight

Accessory

Conformity

*Selectable by SD Manager 3.

*The Vs indicates a supply voltage value in your environment.

Object resolution (Detection capability) 

Protective height

Operating 

range

Response

time

Effective aperture angle (EAA) (IEC 61496-2) 

Light source

Power supply voltage (Vs)

Current consumption

Safety outputs (OSSD) 

Auxiliary output

Input 

voltage 

Protective circuit

Mutual interference prevention 

 

Safety-related functions 

 

Ambient temperature

Ambient humidity

Degree of protection (IEC 60529)

Cable 

extension 

 

PFH

D

See F3SG-SR/PG User's Manual for more information on cable extension.

Long

Short

Normal mode

×2 Slow 

mode *

×4 Slow

mode *

×8 Slow 

mode *

ON to OFF

OFF to ON

ON to OFF

OFF to ON

ON to OFF

OFF to ON

ON to OFF

OFF to ON

TEST

OPERATING RANGE 

SELECT Input

RESET/EDM

MUTE A/B, 

PRE-RESET

Root cable