background image

A-178

Standard Photoelectric Sensors

Application

Ordering Information

Sensors

 

Accessories (Order Separately)

Shape

Connection 

method

Sensing/Setting range

Operating mode

Model

NPN output

PNP output

Pre-wired with 
M12-connector

Light-ON/Dark-ON cable 
connection selectable

F3C-AL14-M1J

F3C-AL44-M1J

Detection of the object 
between 150 to 700 mm max. 
on the conveyor.

F3C

The cup of yogurt

Detection of food being transferred

Since it is a reflection 
type, a viewport is 
OK with one place!

F3C

Wafer

Detection of wafers through view port 
(Reflective model)

Red light

120 170

Setting range

120 to 700 mm

Sensing distance

700 mm

Mounting Brackets

Shape

Model

Quantity

E39-L40

1

Sensor I/O Connectors

Cable spec-

ifications

Shape

Cable type

Model

Standard 

cable

2 m

4 con-

ductors

XS2F-D421-D80-A

5 m

XS2F-D421-G80-A

2 m

XS2F-D422-D80-A

5 m

XS2F-D422-G80-A

Robot cable 

(for vibra-
tion resis-

tance)

2 m

XS2F-D421-D80-R

5 m

XS2F-D421-G80-R

2 m

XS2F-D422-D80-R

5 m

XS2F-D422-G80-R

Straight 
type

L type

Straight 
type

L type

Summary of Contents for F3C-AL

Page 1: ...x4 mm red spot Secure detection of shiny surface Ensures stable detection of a 45 degree shiny surface Detec tion of pouches laminated packages or like minimizes setup change time Unaffected by a shin...

Page 2: ...being transferred Since it is a reflection type a viewport is OK with one place F3C Wafer Detection of wafers through view port Reflective model Red light 120 170 Setting range 120 to 700 mm Sensing...

Page 3: ...ax residual voltage 2 V max PNP open collector output type Light ON Dark ON cable connection selectable Protective circuits Reverse polarity protection output short circuit protection mutual interfere...

Page 4: ...Setting distance mm 20 15 10 5 0 150 200 300 400 500 600 700 Sensing object White paper reflectivity 90 Black paper reflectivity 5 Black and white error 800 700 600 500 400 300 200 100 0 90mm 50mm 185...

Page 5: ...transistor Load Relay 10 to 30 VDC Main circuit Load Relay Operation selectable 150 mA max Light indicator red Stability indicator green 0V ZD 1 4 3 2 Connector Pin Arrangement 3 1 2 4 10 to 30 VDC I...

Page 6: ...ground object Remove the detected object and turn the adjustment knob clockwise until the LIGHT indicator red lights This is the position B Then turn the adjustment knob coun terclockwise until the LI...

Page 7: ...has load short circuit protection If a load short circuit or like has occurred the output turns OFF Therefore recheck the wiring and switch power on again This resets the short circuit protection cir...

Page 8: ...than spot diameter Correct operation The moving direction of the sensor or object should be prefer ably along the optical axis of the light beam Lateral approach is also possible Movement from the top...

Reviews: