background image

ES1-N

7

Safety Precautions

Be sure to read the precautions for all Infrared Thermosensors in the website at: http://www.ia.omron.com/. 

Key to Warning Symbols

Meaning of Product Safety Symbols

Warning Symbols

The ES1-LW50L-N and ES1-LW100L-N contain a Class 1 
laser. Never look at the laser light or allow the laser light to 
enter the eye. Do not allow laser light reflected from a mirror 
to enter the eye.

Never disassemble the product. Risk of vision 
impairment or blindness from laser light leakage if 
disassembled.

Minor injury due to electric shock may occasionally occur. 
Do not touch the connections such as the temperature 
controller while power is being supplied.

Make sure that the product's metal enclosure is not 
touching the voltage-applied conductors. For 
touching the product's metal enclosure with bare 
hands, electrical shock may occur. The product's 
metal enclosure and internal circuits, the power 
supply, current output, or USB port are not isolated.

Electric shock, fire, or malfunction may occasionally 
occur. Do not allow metal objects, conducting wires, 
shavings or powder from installation work, water, or 
other foreign objects to enter the product.

Do not use the product where subject to flammable or 
explosive gas. Otherwise, minor injury from 
explosion may occasionally occur.

Never disassemble, modify, or repair the product or 
touch any of the internal parts. Minor electric shock, 
fire, or malfunction may occasionally occur.

If the output relays are used past their life expectancy, 
burning may occasionally occur. Always consider the 
application conditions and use the output relays 
within their rated load and electrical life expectancy.

When measuring an object at high temperature, keep 
the sensor a sufficient distance away from the object 
and measure within ambient temperature.

• The setting gauge is flammable. Do not allow flame or 

fire near the setting gauge.

• If the object of measurement is at high temperature, do 

not use the setting gauge.

• Use the setting gauge only after the temperature of the 

object of measurement has cooled to normal 
temperature.

WARNING

Indicates a potentially hazardous 

situation which, if not avoided, will 

result in minor or moderate injury, or 

may result in serious injury or death. 

Additionally there may be significant 

property damage.

CAUTION

Indicates a potentially hazardous 

situation which, if not avoided, is 

likely to result in minor or moderate 

injury or property damage.

Indicates the possibility of the risk of laser beam 

exposure

Indicates prohibitions when there is a possibility 

of injury, such as from electric shock, as the 

result of disassembly

Indicates possibility of electric shock under 

specific conditions

Indicates non-specific general prohibitions

Indicates non-specific general cautions, 

warnings, and dangers

Indicates the possibility of injury by high 

temperature under specific conditions

 WARNING

 Caution

Summary of Contents for ES1 N Series

Page 1: ...ering Information 1 This value is based on the 90 energy limit The actual target object must be at least 1 5 times larger than this size 2 By default the measurement range is 0 to 500 C but you can ch...

Page 2: ...0 5 C Within 1 C Measurement temperature 50 to 0 C Within 0 5 C 0 to 500 C Within 1 C 500 to 1 000 C Within 0 5 C Within 1 C Measurement temperature 50 to 0 C Within 0 5 C 0 to 500 C Within 1 C 500 t...

Page 3: ...the target size lower value is the distance Long and short dashes line is the center of target Short dashes line is the center of laser pointer GND Power output cable White Black Red Shield Ground Cu...

Page 4: ...8 0 5 17 3 15 1 4 5 2 3 7 6 40 ES1 LW100 N ES1 LW100L N The ES1 LW100 N does not have the Laser output port 6 and the laser switch 7 32 3 90 3 1 20 32 13 14 58 0 5 17 3 15 7 6 4 5 2 3 24 dia 40 No Nam...

Page 5: ...wer is ON Adjust the position and mounting angle so that the laser pointer beam hits a point 15 mm above the center of the object The laser pointer beam is parallel to the center axis of the object Us...

Page 6: ...ying Process and Printing Checking for Poor Contacts on a Switchboard Temperature Control during the Gluing Process of Product Manufacturing Thermal Insulation Quality Control Ingredient silo Mixer Pi...

Page 7: ...uch any of the internal parts Minor electric shock fire or malfunction may occasionally occur If the output relays are used past their life expectancy burning may occasionally occur Always consider th...

Page 8: ...emperature controller and wire correctly 4 Allow as much space as possible between the controller and devices that generate a powerful high frequency or surge Separate the high voltage or large curren...

Page 9: ...however no responsibility is assumed for clerical typographical or proofreading errors or omissions Terms and Conditions Agreement Read and understand this catalog Please read and understand this cata...

Page 10: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Reviews: