ES1-N

2

Ratings and Specifications

*1.

By default, the measurement range is 0 to 500°C, but you can change the range to -50 to +500°C or -50 to +1,000°C on the ES1-TOOLS.

*2.

Industrial electromagnetic environment (EN/IEC 61326-1 Table 2)

Measurement error is within ±10°C.

Type

Without laser pointer

With laser pointer

Item

Model

ES1-LP3-N

ES1-LP10-N

ES1-LW50-N

ES1-LW100-N

ES1-LW50L-N

ES1-LW100L-N

Detection element

Thermopile

Lens

Silicon

Measurement 
wavelength

8 to 14 µm

Current 
output

USB 
output

Resolution: Approx. 0.1°C

Current 
output

4 to 20 mA, -50 to 500°C 

*

1

Load impedance: 250 

Ω

 max.

Resolution: Approx. 0.24 

μ

A

4 to 20 mA, -50 to 1,000°C 

*1

Load impedance: 250 

Ω

 max.

Resolution: Approx. 0.24 

μ

A

4 to 20mA/-50 to 500°C 

*1

Load impedance: 250 

Ω

 max.

Resolution: Approx. 0.24 

μ

A

4 to 20 mA, -50 to 1,000°C 

*1

Load impedance: 250 

Ω

 max.

Resolution: Approx. 0.24 

μ

A

Power supply voltage

12 to 24 VDC/USB bus power (Functions other than current output can be used with USB bus power only)

Allowed power supply 
voltage fluctuation

95% to 105% of the power supply voltage

Current consumption

30 mA max. (24 VDC)

• 30 mA max. (24 VDC, Not using laser pointer)
• 40 mA max. (24 VDC, Using laser pointer)

Cable length

2 m ±5 cm

Measurement accuracy

USB output

• Within ±(-8%rdg+1)°C

(Measurement temperature: -50 to 0°C)

• Within ±1°C

(0 to 200°C)

• Within ±0.5%rdg°C

(200 to 500°C)

Current output

• Difference from USB output is (±0.1% of output 

range) °C or less

USB output

• Within ±(-8%rdg+1)°C 

(Measurement 

temperature: -50 to 0°C)

• Within ±1°C

(0 to 200°C)

• Within ±0.5%rdg°C

(200 to 1,000°C)

Current output

• Difference from USB 

output is (±0.1% of 
output range) °C or less

USB output

• Within ±(-8%rdg+1)°C 

(Measurement 

temperature: -50 to 0°C)

• Within  ±1°C

(0 to 200°C)

• Within ±0.5%rdg°C

(200 to 500°C)

Current output

• Difference from USB 

output is (±0.1% of 
output range) °C or less

USB output

• Within ±(-8%rdg+1)°C 

(Measurement 

temperature: -50 to 0°C)

• Within  ±1°C

(0 to 200°C)
Within ±0.5%rdg°C
(200 to 1,000°C)

Current output

• Difference from USB 

output is (±0.1% of 
output range) °C or less

Reproducibility

• Within 0.5°C

• Within ±1°C

(Measurement 
temperature: -50 to 0°C)

• Within ±0.5°C

(0 to 500°C)

• Within ±1°C

(500 to 1,000°C)

• Within 0.5°C

• Within  ±1°C

(Measurement 

temperature: -50 to 0°C)

• Within  ±0.5°C

(0 to 500°C)

• Within  ±1°C

(500 to 1,000°C)

Temperature drift

• Within ±0.5°C/°C

(Measurement temperature: -50 to 0°C)

• Within ±0.25°C/°C

(Measurement temperature: 0 to 500°C)

• Within ±0.5°C/°C

(Measurement 
temperature: -50 to 0°C)

• Within ±0.25°C/°C

(Measurement 
temperature: 0 to 500°C)

• Within ±0.5°C/°C

(Measurement 
temperature: 500 to 
1,000°C)

• Within ±0.5°C/°C

(Measurement 
temperature: -50 to 0°C)

• Within ±0.25°C/°C

(Measurement 
temperature: 0 to 
500°C)

• Within  ±0.5°C/°C

(Measurement 
temperature: -50 to 0°C)

• Within ±0.25°C/°C

(Measurement 
temperature: 0 to 500°C)

• Within  ±0.5°C/°C

(Measurement 
temperature: 500 to 
1,000°C)

Influence 
of EMS 

*

2

Radiated 
electromag
netic field 
immunity

Within ±10°C (80 MHz to 1.0 GHz)

Immunity 
Conducted 
Disturbance

Within ±10°C (150 kHz to 80 MHz)

Response time

Current output: 0.14 s max. (95% response, movement average of 1)

Emissivity setting

Factory setting: 0.95: Can be changed to a value between 0.100 and 1.999 with the setting tool

Moving average 
function

Factory setting: 10
Can be changed to a value between 1 and 1,000 
with the setting tool

Factory setting: 50
Can be changed to a value 
between 1 and 1,000 with 
the setting tool

Factory setting: 10
Can be changed to a value 
between 1 and 1,000 with 
the setting tool

Factory setting: 50
Can be changed to a value 
between 1 and 1,000 with 
the setting tool

Operating temperature 
and humidity range

Temperature:0 to 55°C, Humidity:35 to 85% (without condensation)

Storage temperature 
and humidity range

20 to 55°C (without condensation)

Vibration
resistance

Malfunction

10 to 55 Hz, 20 m/s

2

 along 3 axes for 10 min.

Destruction

10 to 55 Hz, 0.75-mm single amplitude, along 3 axis for 2 hours

Degree of protection

None

Applicable safety 
standards

CE, KC, FCC, RCM
-

IEC60825-1, PSC, FDA

Dimensions

L: 58, W: 32, H: 40 mm

L: 90.3, W: 32, H: 40 mm

L: 60.4, W: 32, H: 40 mm

L: 92.7, W: 32, H: 40 mm

Weight

Approx. 95 g

Approx. 115 g

Approx. 95 g

Approx. 115 g

Standard accessories

User’s Manual, Mounting 
Brackets, Power/output cable (2 
m), and Installation Gauge

User’s Manual, Mounting Brackets, and Power/output cable (2 m)

Summary of Contents for ES1 N Series

Page 1: ...ering Information 1 This value is based on the 90 energy limit The actual target object must be at least 1 5 times larger than this size 2 By default the measurement range is 0 to 500 C but you can ch...

Page 2: ...0 5 C Within 1 C Measurement temperature 50 to 0 C Within 0 5 C 0 to 500 C Within 1 C 500 to 1 000 C Within 0 5 C Within 1 C Measurement temperature 50 to 0 C Within 0 5 C 0 to 500 C Within 1 C 500 t...

Page 3: ...the target size lower value is the distance Long and short dashes line is the center of target Short dashes line is the center of laser pointer GND Power output cable White Black Red Shield Ground Cu...

Page 4: ...8 0 5 17 3 15 1 4 5 2 3 7 6 40 ES1 LW100 N ES1 LW100L N The ES1 LW100 N does not have the Laser output port 6 and the laser switch 7 32 3 90 3 1 20 32 13 14 58 0 5 17 3 15 7 6 4 5 2 3 24 dia 40 No Nam...

Page 5: ...wer is ON Adjust the position and mounting angle so that the laser pointer beam hits a point 15 mm above the center of the object The laser pointer beam is parallel to the center axis of the object Us...

Page 6: ...ying Process and Printing Checking for Poor Contacts on a Switchboard Temperature Control during the Gluing Process of Product Manufacturing Thermal Insulation Quality Control Ingredient silo Mixer Pi...

Page 7: ...uch any of the internal parts Minor electric shock fire or malfunction may occasionally occur If the output relays are used past their life expectancy burning may occasionally occur Always consider th...

Page 8: ...emperature controller and wire correctly 4 Allow as much space as possible between the controller and devices that generate a powerful high frequency or surge Separate the high voltage or large curren...

Page 9: ...however no responsibility is assumed for clerical typographical or proofreading errors or omissions Terms and Conditions Agreement Read and understand this catalog Please read and understand this cata...

Page 10: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Reviews: