background image

E9NC-AA/VA

7

Safety Precautions

Be sure to read the precautions for all models in the website at: http://www.ia.omron.com/.

Warning Indications

Meaning of Product Safety Symbols

This product is not designed or rated for ensuring 
safety of persons either directly or indirectly.
Do not use it for such purposes.

Do not use the product with voltage in excess of the 
rated voltage.
Excess voltage may result in malfunction or fire.

Never use the product with an AC power supply.
Otherwise, explosion may result.

The following precautions must be observed to ensure safe

operation of the product. Doing so may cause damage or fire.

• Do not install the product in the following locations.

(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding 

the rated values

(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subject to strong magnetic field or electric field

• Do not use the product in environments subject to flammable or 

explosive gases.

• Do not use the product in any atmosphere or environment that 

exceeds the ratings.

• To secure the safety of operation and maintenance, do not install 

the product close to high-voltage devices and power devices.

• High-voltage lines and power lines must be wired separately from 

the product. Wiring them together or placing them in the same duct 
may cause induction, resulting in malfunction or damage.

• Do not apply any load exceeding the ratings. Doing so may cause 

damage or fire.

• Do not short the load. Doing so may cause damage or fire.

• Connect the load correctly.
• Do not miswire such as the polarity of the power supply.
• Do not use the product if the case is damaged.
• Burn injury may occur. The product surface temperature rises 

depending on application conditions, such as the ambient 
temperature and the power supply voltage. Attention must be paid 
during operation or cleaning.

• When setting the sensor, be sure to check safety such as by 

stopping the equipment.

• Be sure to turn off the power supply before connecting or 

disconnecting wires.

• Do not attempt to disassemble, repair, or modify the product in any 

way.

• When disposing of the product, treat it as industrial waste.
• Do not use the Sensor in water, rain, or outdoors.
• Process the unwired terminals so as not to contact other wiring or 

devices.

• Connect the Sensor Head correctly. Otherwise, it might be broken 

or catch fire.

• Do not connect any sensor heads differently designed from the 

amplifier input specification (voltage/current range and current 
consumption). Otherwise, it might be broken or catch fire.

• To use this device as connecting with each other, be sure to 

connect with the same power supply and turn ON the power 
simultaneously.
Using a separate power supply will influence the functions when 
connecting the devices to use them.

• The maximum number of connectable amplifiers is different 

depending on the current consumption of the sensor head. The 
number of the amplifiers connected must be within the specified 
limit. Otherwise, they might be broken or catch fire.

• If power is supplied from an external power source to the sensor, 

excessive current flows to this product or sensor, so that the device 
might be broken or catch fire. Use this product as supplying power 
from it to the sensor.

• When connecting this device with a sensor, confirm product 

performance well before using the product.

• UL Standard Certification

Only the sensors with Enhanced UL Certification Mark are certified 
by UL. They are intended to be supplied by a "Class 2 circuit". 
When used in United States and Canada, Please use the same 
Class 2 source for input and output. The overcurrent protection 
current rating is 2 A max. They were evaluated as Open type and 
shall be installed within a enclosure.

Warning level

Indicates a potentially hazardous situation 
which, if not avoided, will result in minor or 
moderate injury, or may result in serious 
injury or death. Additionally, there may be 
significant property damage.

Precautions for 

Safe Use

Supplementary comments on what to do or 
avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do or 
avoid doing, to prevent failure to operate, 
malfunction or undesirable effect on 
product performance.

General prohibition

Indicates the instructions of unspecified prohibited 
action.

Caution, explosion

Indicates the possibility of explosion under specific 
conditions.

Caution, fire

Indicates the possibility of fire under specific 
conditions.

 

 WARNING

Precautions for Safe Use

WARNING

Summary of Contents for E9NC-AA0

Page 1: ...n of the sensor head Ordering Information Amplifier unit Refer to Dimensions on page 9 A Sensor Communications Unit is required if you want to use the Amplifier Unit on a network For the most recent i...

Page 2: ...bsite for details The Distributed Sensor Unit can be connected to any of the Sensor Communications Units EtherCAT is a registered trademark and patented technology licensed by Beckhoff Automation GmbH...

Page 3: ...both sub and main digital display white OUT indictor orange NO NC indicator orange ST indicator blue zero reset indicator green OUT selective indicator orange two lamps only Protection circuit Power...

Page 4: ...ty range Operating and storage 35 to 85 RH with no condensation Height 2 000 m max Installation environment Pollution level 3 according to IEC60947 1 Insulation resistance 20 M min at 500 VDC Dielectr...

Page 5: ...Operate Reset Between 24 VDC and black leads OUT indicator orange Output transistor Load e g relay Sensing object NC lit Yes No Lit Not lit ON OFF Operate Reset Between 0 VDC and black leads OUT indi...

Page 6: ...icator Orange Indicates the current NO NC setting status OUT Indicator Orange Turn ON when the judgment output is ON OUT1 Selection Indicator OUT2 Selection Indicator The indicator for the selected ou...

Page 7: ...product in any way When disposing of the product treat it as industrial waste Do not use the Sensor in water rain or outdoors Process the unwired terminals so as not to contact other wiring or device...

Page 8: ...for the cable length between Preamplifiers and Amplifier Units Mounting the Amplifier Units Mounting on DIN Track 1 Let the hook on the Amplifier Unit s Fiber Unit connection side catch the track 2 P...

Page 9: ...NICATION POSITION E9NC AA0 VA0 DIN RAIL PFP N SOLD SEPARATELY 4 2 5 19 2 3 9 OUT2 OPTIONAL INDICATOR 2 OUT2 INDICATOR 2 OUT1 OPTIONAL INDICATOR OUT1 INDICATOR MEASURED DATA DISPLAY WHITE DIGITAL DISPL...

Page 10: ...25 10 10 1 000 25 25 15 1 1 5 29 2 24 27 35 0 3 16 PFP 100N2 50 11 5 10 M4 8 panhead screw M4 spring washer 4 8 1 3 1 8 1 8 1 6 2 10 35 5 35 3 Materials Iron zinc plating End Plate PFP M M4 8 panhead...

Page 11: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 12: ...9 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron com Kyo...

Reviews: