background image

E8F

E8F

7

(6) Buzzer Mode Settings

Set the buzzer mode to 0 if the buzzer function is not required.

Note:

The mode is set to 3 before shipping.

Set value

Contents

0

The buzzer is always OFF.

1

The buzzer is ON when the ON/OFF output
transistor is ON.

2

The buzzer is ON when an error is
detected.

3

The buzzer is ON when the Up or Down
Key is pressed when setting the values.

4

The functions of set values 1 and 3.

5

The functions of set values 2 and 3.

 Error Indication

LCD

Meaning

Remedy

E1

The ON/OFF output and error output transistor have excessive current.

Change the load to a proper one.

E2

No zero point adjustment is possible when the ZERO Key is pressed
because pressure is imposed on the pressure port.

Eliminate the pressure imposed on the pressure
port.

E3

Excessive pressure is imposed on the pressure port.

Reduce the pressure to the rated value or less.

E4

Reversed pressure is imposed.

Do not impose reversed pressure.

E5

The Sensor has a failure.

Contact your OMRON representatives.

E6

The voltage imposed on the Sensor is not within the rated value.

Impose the voltage within the rated value.

Note:

1. If the load is short-circuited or excessive current flows to the load, the green indicator will flash and the ON/OFF output and error

output will be turned OFF.

2. If there is an error other than a load short-circuit or excessive current error (i.e., E2 to E6), the green indicator will be turned OFF and

the error output transistor will be turned ON. Therefore, nullify the ON/OFF output at the time of error detection.

Zero Point Adjustment

Usually, no zero point adjustment is necessary. If the zero point
should shift due to secular changes (i.e., a value other than 00 is dis-
played with no pressure imposed), press the ZERO Key for zero
point adjustment.

Perform zero point adjustment with no pressure imposed.

ON/OFF Set Value Check on E8F in Operation

Press the Up Key to check the ON set value.

Press the Down Key to check the OFF set value.

Mounting

The zinc die-cast pressure leading part incorporates an R(PT) 1/8
taper screw and M5 x P0.8 female screw. The taper screw must be
used in combination with an Rc(PT) 1/8 female taper screw.

Apply sealing tape around the taper screw so that there will be no
pressure leakage. Make sure that the tightening torque of the taper
screw is 9.8 N 

S

 m (100 kgf 

S

 cm) or less.

Make sure that the tightening torque of the M5 female screw is 
2.3 N 

S

 m (23 kgf 

S

 cm) or less.

When tightening the male screw, apply a 12-mm wrench to the hex-
agonal portion of the pressure port. Do not tighten the male screw
while holding the plastic case.

When attaching the mounting bracket to the E8F, make sure that the
tightening torque applied to the M2.5 screw is 0.29 N 

S

 m (3 kgf 

S

 cm)

or less.

Hexagonal portion

Summary of Contents for E8F

Page 1: ...98 kPa NPN open collector 1 to 5 V E8F A01C os e essu e 0 to 980 kPa o e co ec o o 5 E8F B10C Negative pressure 0 to 101 kPa E8F AN0C Positive pressure 0 to 1 kgf cm2 E8F 01C os e essu e 0 to 10 kgf c...

Page 2: ...tput 6 ms max Linear output 1 to 5 V with output impedance of 1 k and permissible resistive load of 500 k min ON OFF output NPN open collector NO NC Load current 100 mA max Output applied voltage 30 V...

Page 3: ...display in which the third digit displays only 0 or 1 0 or 1 0 to 9 0 to 9 Third digit Second digit First digit Characteristics Voltage influence 1 5 FS max Temperature influence 3 FS max Degree of p...

Page 4: ...al E8F 01C Linearity Typical E8F 01C Linear output voltage V Pressure kgf cm2 Linearity deviation FS Pressure kgf cm2 Nomenclature LCD display 21 2 digit display DOWN Key UP Key Green indicator Normal...

Page 5: ...sure ON point OFF point OFF point Output see note ON OFF OUT indicator red RUN indicator green ON OFF ON OFF Normally Closed Output in Hysteresis Mode OFF point 3 digits ON point 3 digits OFF point 3...

Page 6: ...re stored in the EEPROM and not lost when the E8F is turned OFF If the Up Key is pressed in mea surement mode the set ON point will be displayed for two seconds If the Down Key is pressed instead the...

Page 7: ...F 2 If there is an error other than a load short circuit or excessive current error i e E2 to E6 the green indicator will be turned OFF and the error output transistor will be turned ON Therefore null...

Page 8: ...ted E8F Wiring cord Atmosphere inlet M5 screw depth 6 R PT 1 8 zinc die cast 1 dia hole Two M2 5 x P0 45 Wiring cord 3 dia Mounting Bracket Mounting Dimensions Material SPCC uni chrome plating t 1 2 M...

Page 9: ...tting at room temperature If a highly precise pressure setting is required use a manometer Nullify the ON OFF output at the time of error detection If the use of the E8F requires the IP66 enclosure ra...

Page 10: ...E8F E8F 10...

Page 11: ...E8F E8F 11...

Page 12: ...ku Osaka 540 6028 Japan Phone 81 6 949 6012 Fax 81 6 949 6021 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces multiply by 0...

Reviews: