E6C-N
E6C-N
2
Origin Reset Ensures Easy Origin Setting
after Enclosed Mounting
In addition to the conventional reset function for multi-rotation
data, a reset function for single-rotation data is available, which
ensures easy origin setting of the E6C-N after enclosed mount-
ing and saves the number of steps required for the reset opera-
tion.
Data Stored with No Backup Power Supply
Multi-rotation data is stored in the non-volatile built-in memory
at the time of power failure, thus eliminating the need for a con-
ventional backup power supply and simplifying the system con-
figuration. Multi-rotation detection is, however, not possible at
the time of power failure, and multi-rotation data is compen-
sated according to the rotational operation within
±
80
°
of the
position at the time of power failure.
Select from Two Models According to the
Application
Select one suited to the application from a line of shaft and hol-
low shaft models. The hollow shaft model absorbs the vibration
of the driving axis with the special built-in spring.
Power turned on
Data read from built-in memory
Data output
(data after power turned off)
Data reset
Single-rotation data is output with
the arithmetic operation of abso-
lute codes. Therefore, the reliabil-
ity of data after reset is ensured.
Power turned off
Data stored in built-in memory
Data storage
Compensating multi-rotation
data within
±
80
°
Great Cost Reduction
The E6C-N is considerably less expensive than the conven-
tional E6C-M. This was achieved through the use of a plastic
casing and ASIC, the minimization of functions to ones that are
truly useful, and improvements in assembly.
CE Marking