E5EC-800/E5EC-B-800/E5AC-800

36

Accessories (Order Separately)

10

91

2

3.8

Terminal Covers

E53-COV24 (Three Covers provided.)

Waterproof Packing

Y92S-P9 (for DIN 48 

×

 96)

The Waterproof Packing is provided with the 
Temperature Controller.
Order the Waterproof Packing separately if it 
becomes lost or damaged.
The degree of protection when the Waterproof 
Packing is used is IP66.
To maintain an IP66 degree of protection, the 
Waterproof Packing and the Port Cover for the front-
panel Setup Tool port must be periodically replaced 
because they may deteriorate, shrink, or harden 
depending on the operating environment.
The replacement period will vary with the operating 
environment.
Check the required period in the actual application.
Use 3 years or sooner as a guideline.

Y92S-P10 (for DIN 96 

×

 96)

Mounting Adapter

Y92F-51
(Two Adapters provided.)

One pair is provided with the Controller.
Order this Adapter separately if it becomes lost or damaged.

131.7 

115.6 28.9

21.9 

(2)

Watertight Cover

Y92A-96N (96 

×

 96)

Watertight Cover

Y92A-49N (48 

×

 96)

131.7 

67.6 28.9

21.9 

(2)

Summary of Contents for E5CC-U-800

Page 1: ... E5CC 800 U 800 E5CC B 800 Refer to Safety Precautions on page 58 Refer to your OMRON website for the most recent information on applicable safety standards CSA conformance evaluation by UL 48 48 mm Screw Terminal Blocks E5CC 800 48 48 mm Plug in Models E5CC U 800 48 48 mm Push In Plus Terminal Blocks E5CC B 800 Dual displays PV SV 4 digit displays E5CC 800 E5CC B 800 E5CC U 800 Indication Accurac...

Page 2: ...ay output 24 VAC VDC E5CC RX2DSM 800 Voltage output E5CC QX2DSM 800 Linear current output E5CC CX2DSM 800 Relay output One Two 100 to 240 VAC E5CC RX2ASM 801 Voltage output E5CC QX2ASM 801 Relay output 24 VAC VDC E5CC RX2DSM 801 Voltage output E5CC QX2DSM 801 Relay output RS 485 100 to 240 VAC E5CC RX2ASM 802 Voltage output E5CC QX2ASM 802 Relay output 24 VAC VDC E5CC RX2DSM 802 Voltage output E5C...

Page 3: ...n the panel has already been prepared for an E5B Controller DIN Track Mounting Adapter for E5CC 800 Sockets for E5CC U 800 Waterproof Cover Mounting Adapter Note This Mounting Adapter is provided with the Digital Temperature Controller Front Covers Model E53 COV17 E53 COV23 3pcs Model Y92S P8 Hole diameter Model 5 8 mm E54 CT1 5 8 mm E54 CT1L 12 0 mm E54 CT3 12 0 mm E54 CT3L Model Y92F 45 Model Y9...

Page 4: ...V 10 mA reference value Voltage output for driving SSR Output voltage 12 VDC 20 PNP max load current 21 mA with short circuit protection circuit Linear current output 1 4 to 20 mA DC 0 to 20 mA DC load 500 Ω max resolution approx 10 000 Auxiliary output Number of outputs 2 Output specifications SPST NO relay outputs 250 VAC E5CC 800 E5CC U 800 models with 2 output 3 A resistive load E5CC B 800 mod...

Page 5: ...istance thermometer Thermocouple Infraredtemperature sensor Sensor specifica tion Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 0 100 200 2300 1800 1700 1700 1300 1300 1300 850 850 850 600 500 0 500 0 500 0 400 0 400 400 0 400 400 0 260 120 165 100 0 100 0 90 100 0 0 0...

Page 6: ...t with standby sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set point 9 Absolute value lower limit The alarm will turn ON if the process value is smaller than the alarm value X regardless of the set point 10 Absolute value upper limit with standby sequenc...

Page 7: ...6 Refer to the E5 C Digital Controllers User s Manual Cat No H174 for information on the operation of the standby sequence 7 Refer to the E5 C Digital Controllers User s Manual Cat No H174 for information on the loop burnout alarm LBA 8 Refer to the E5 C Digital Controllers User s Manual Cat No H174 for information on the PV change rate alarm 9 When heating cooling control is performed the MV abso...

Page 8: ... greater 1 digit max Analog input 1 FS 1 digit max CT input 5 FS 1 digit max Influence of voltage 3 Influence of EMS at EN 61326 1 Input sampling period 50 ms Hysteresis Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 01 to 99 99 FS in units of 0 01 FS Proportional band P Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units ...

Page 9: ... Interface RS 485 Retry function None Communications buffer 217 bytes Communications response wait time 0 to 99 ms Default 20 ms Programless communications 1 You can use the memory in the PLC to read and write E5 C parameters start and stop operation etc The E5 C automatically performs communi cations with PLCs No communications program ming is required Number of connected Temperature Controllers ...

Page 10: ...trol output 1 Relay output 250 VAC 3A resistive load Voltage output for driving SSR 12 VDC 21 mA Linear current output 0 to 20 mA DC 4 to 20 mA DC Load 500 Ω max Relay outputs Models with 2 auxiliary outputs 250 VAC 3 A resistive load 17 18 12 15 16 1 2 13 14 3 11 4 6 7 8 9 10 5 6 4 5 6 5 6 Pt A B B mA 5 4 V 5 V 6 4 TC 4 I no polarity 11 12 11 12 100 to 240 VAC 24 VAC VDC Auxiliary outputs 1 2 7 8...

Page 11: ...or XOBA7 current transformer that is UL Listed for field wiring external wiring and not the factory wiring internal wiring 23 19 22 1 2 17 18 3 15 24 16 6 8 9 14 21 5 13 20 4 12 11 10 7 8 6 7 8 7 8 8 Pt A B B mA 7 6 V 7 V 6 TC 6 I 13 14 15 16 9 10 11 12 100 to 240 VAC Auxiliary output 2 Auxiliary output 1 2 Auxiliary Outputs 3 Input Power Supply 5 Sensor Temperature Analog Input 6 Options OUT1 R 1...

Page 12: ... output 1 Relay output V mA The E5CC U is set for a K type thermocouple input type 5 by default An input error s err will occur if the input type setting does not agree with the temperature sensor Check the input type Sensor temperature analog input Auxiliary output 2 Control output cooling side Control output 1 Control output 1 100 to 240 VAC 24 VAC DC no polarity RW Models with 1 Relya Output QX...

Page 13: ... current output Relay output Auxiliary outputs 1 2 Reinforced insulation Functional isolation Power supply Sensor input Voltage output for driving SSR Relay output Auxiliary outputs 1 and 2 Reinforced insulation Functional isolation Power supply Press O Key once to go to Adjustment Level Press O Key for at least 3 seconds to go to Initial Setting Level Use the M Key to change to another parameter ...

Page 14: ...ler When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the specifications 71 4 67 4 4 1 58 Adapter Accessory 48 48 44 8 44 8 44 8 44 8 Waterproof Packing Accessory E5CC B 800 58 76 8 58 6 4 14 2 48 48 Adapter Accessory 44 8 44 8 45 0 6 0 45 0 6 0 45 0 6 0 60 min 48 number of units 2 5 1 0 0 Panel Cuto...

Page 15: ...vided only with the E5CC 800 E5CC B 800 It is not included with the E5CC U 800 Order the Waterproof Packing separately if it becomes lost or damaged The Waterproof Packing can be used to achieve an IP66 degree of protection Deterioration shrinking or hardening of the waterproof packing may occur depending on the operating environment Therefore periodic replacement is recommended to ensure the leve...

Page 16: ...apter when the Front Panel has already been prepared for the E5B 2 Only black is available 50 61 3 5 38 48 80 5 Y92F 52 Mounted to E5CC 800 Note 1 This Adapter cannot be used together with the Terminal Cover Remove the Terminal Cover to use the Adapter 2 This Adapter cannot be used with the E5CC B This Adapter is used to mount the E5CC 800 to a DIN Track If you use the Adapter there is no need for...

Page 17: ... type Please use it for the mis operation prevention etc 40 0 2 4 5 5 6 7 8 4 3 2 1 9 10 11 70 max 4 Eleven M3 5 7 5 sems screws 7 8 Two 4 5 dia holes 50 max 3 31 2 max 35 4 Mounting Holes Terminal Layout Internal Connections Top View Two 4 5 dia mounting holes Note 1 A model with finger protection P2CF 11 E is also available 2 You cannot use the P2CF 11 or P2CF 11 E together with the Y92F 45 Note...

Page 18: ... E54 CT1L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 100Ω RL 10Ω 10 1 100mV 10 1 100μV 10 1kΩ Output voltage Eo V r m s E54 CT1L 5 8 dia Filler epoxy Case PBT Shrinkable tube Two 3 5 dia Cable AWG18 25 2 5 115 5 8 21 10 5 40 30 5 15 10 Mark yellow...

Page 19: ...es E54 CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 1kΩ 100Ω 50Ω RL 10Ω 500Ω 10 1 100mV 10 1 100μV 10 Output voltage Eo V r m s Filler epoxy Case...

Page 20: ...MEMO 20 ...

Page 21: ... Refer to Safety Precautions on page 58 Refer to your OMRON website for the most recent information on applicable safety standards E5EC AC 800 E5EC B 800 CSA conformance evaluation by UL 48 96 mm Screw Terminal Blocks E5EC 800 48 96 mm Push In Plus Terminal Blocks E5EC B 800 96 96 mm Screw Terminal Blocks E5AC 800 E5EC 800 E5EC B 800 4 digit displays Sensor Input Control Output 1 Auxiliary Outputs...

Page 22: ...put RS 485 One Two 100 to 240 VAC E5EC RR2ASM 808 Voltage output Relay output E5EC QR2ASM 808 Relay output Relay output 24 VAC VDC E5EC RR2DSM 808 Voltage output Relay output E5EC QR2DSM 808 Relay output Relay output Four 100 to 240 VAC E5EC RR2ASM 810 Voltage output Relay output E5EC QR2ASM 810 Relay output Relay output 24 VAC VDC E5EC RR2DSM 810 Voltage output Relay output E5EC QR2DSM 810 Linear...

Page 23: ... output E5AC QX1DSM 800 Linear current output E5AC CX1DSM 800 Relay output Three E5AC RX3DSM 800 Voltage output E5AC QX3DSM 800 Linear current output E5AC CX3DSM 800 Relay output RS 485 One Two 100 to 240 VAC E5AC RX3ASM 808 Voltage output E5AC QX3ASM 808 Relay output 24 VAC VDC E5AC RX3DSM 808 Voltage output E5AC QX3DSM 808 Relay output Four 100 to 240 VAC E5AC RX3ASM 810 Voltage output E5AC QX3A...

Page 24: ...l Products Order Separately Terminal Covers for E5EC 800 E5AC 800 Waterproof Packing Note This Waterproof Packing is provided with the Digital Temperature Controller Waterproof Cover Front Port Cover Note This Front Port Cover is provided with the Digital Temperature Controller Mounting Adapter Note This Mounting Adapter is provided with the Digital Temperature Controller Current Transformers CTs ...

Page 25: ...r models with two control outputs Linear current output 4 to 20 mA DC 0 to 20 mA DC load 500 Ω max resolution approx 10 000 Auxiliary output Number of outputs E5EC 800 0 or 2 depend on model E5EC B 800 2 E5AC 800 0 1 2 or 3 depend on model Output specifications SPST NO relay outputs 250 VAC 3 A resistive load Electrical life 100 000 operations Minimum applicable load 10 mA at 5V reference value Ev...

Page 26: ...fraredtemperature sensor Sensor specifica tion Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 100 200 2300 1800 1700 1700 1300 1300 1300 850 850 850 600 500 0 500 0 500 0 400 0 400 400 0 400 400 0 260 120 165 100 0 100 0 90 100 0 0 0 0 0 0 0 0 0 0 0 0 20 0 100 20 0 100 ...

Page 27: ...with standby sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper limit The alarm will turn ON if the process value is larger than the alarm value X regardless of the set point 9 Absolute value lower limit The alarm will turn ON if the process value is smaller than the alarm value X regardless of the set point 10 Absolute value upper limit with standby sequence ...

Page 28: ...rs User s Manual Cat No H174 for information on the operation of the standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the PV change rate alarm This setting cannot be used with a position proportional model 8 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the PV change rate alarm 9 When ...

Page 29: ...and P Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I Standard heating cooling or Position proportional Close 0 to 9999 s in units of 1 s 0 0 to 999 9 s in units of 0 1 s Position proportional Floating 1 to 9999 s in units of 1 s 0 1 to 999 9 s in units of 0 1 s Derivative time D 0 to 9999 s in units of 1 s 0 0 to 999 9 s...

Page 30: ...ol None Interface RS 485 Retry function None Communications buffer 217 bytes Communications response wait time 0 to 99 ms Default 20 ms Programless communications 1 You can use the memory in the PLC to read and write E5 C parameters start and stop operation etc The E5 C automatically performs communi cations with PLCs No communications program ming is required Number of connected Temperature Contr...

Page 31: ...t 1 Relay output 250 VAC 3 A resistive load Relay output 250 VAC 5 A resistive load 1 Control output Models with 1 Relay Output Models with 1 Voltage Output for Driving SSR Models with Voltage Output for Driving SSR and Relay Output Models with 2 Relay Outputs Models with Linear Current Output and Relay Output Models with 1 Linear Current Output 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 3 4 5 6 RX R...

Page 32: ...V1 B A RS 485 Communications 2 event inputs Models with 1 Relay Output Models with Voltage Output for Driving SSR and Relay Output Models with 2 Relay Outputs RX QR RR 5 6 7 8 5 6 7 8 5 6 7 8 R R R R Q Models with 1 Linear current output CX 5 6 7 8 C OUT1 OUT1 OUT1 OUT2 OUT1 OUT2 Models with 1 Voltage Output for Driving SSR QX 5 6 7 8 Q OUT1 Note 1 The application of the terminals depends on the m...

Page 33: ...value No 3 display Manipulated value or other value Top View of E5EC 800 Use the U D Keys to set the parameter Front panel Press O Key once to go to Adjustment Level Press O Key for at least 3 seconds to go to Initial Setting Level Top View of E5EC B 800 E5EC 800 E5EC B 800 Operation indicators Press the S Key to change the digit default setting Press the M Key to change to another parameter No 1 ...

Page 34: ... panel thickness is 1 to 8 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating temperature specified in the spe...

Page 35: ...p Mounted E5AC 800 Recommended panel thickness is 1 to 8 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers To mount the Controller so that it is waterproof insert the waterproof packing onto the Controller When two or more Controllers are mounted make sure that the surrounding temperature does not exceed the allowable operating te...

Page 36: ...rproof Packing and the Port Cover for the front panel Setup Tool port must be periodically replaced because they may deteriorate shrink or harden depending on the operating environment The replacement period will vary with the operating environment Check the required period in the actual application Use 3 years or sooner as a guideline Y92S P10 for DIN 96 96 Mounting Adapter Y92F 51 Two Adapters p...

Page 37: ...E54 CT1L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 100Ω RL 10Ω 10 1 100mV 10 1 100μV 10 1kΩ Output voltage Eo V r m s E54 CT1L 5 8 dia Filler epoxy Case PBT Shrinkable tube Two 3 5 dia Cable AWG18 25 2 5 115 5 8 21 10 5 40 30 5 15 10 Mark yellow ...

Page 38: ...s E54 CT3 or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 1kΩ 100Ω 50Ω RL 10Ω 500Ω 10 1 100mV 10 1 100μV 10 Output voltage Eo V r m s Filler epoxy Case ...

Page 39: ... complete basic functions A white PV display height 8 5 mm is easy to read when setting up checking alarms and making settings in a control panel Main I O Functions 22 5 mm Wide and DIN Track mounting Type E5DC 800 Refer to Safety Precautions on page 58 Refer to your OMRON website for the most recent information on applicable safety standards Event Inputs None 1 Control Output 1 Relay output Volta...

Page 40: ...C RX0DUM 815 Voltage output E5DC QX0DSM 815 E5DC QX0DUM 815 Linear current output 1 E5DC CX0DSM 815 E5DC CX0DUM 815 Relay output Two 100 to 240 VAC E5DC RX2ASM 800 E5DC RX2AUM 800 Voltage output E5DC QX2ASM 800 E5DC QX2AUM 800 Linear current output 1 E5DC CX2ASM 800 E5DC CX2AUM 800 Relay output 24 VAC VDC E5DC RX2DSM 800 E5DC RX2DUM 800 Voltage output E5DC QX2DSM 800 E5DC QX2DUM 800 Linear current...

Page 41: ...ferent heating and cooling response characteristics Optional Products Order Separately Terminal Unit Current Transformers CTs Lead wires are included with these CTs If UL certification is required use these CTs Mounting Adapters Short Bars End Plate Spacer DIN Tracks Unit Labels End Cover Model E5DC SCT1S Hole diameter Model 5 8 mm E54 CT1 5 8 mm E54 CT1L 12 0 mm E54 CT3 12 0 mm E54 CT3L Model Y92...

Page 42: ... 10 000 Auxiliary outputs Number of outputs 2 depends on model Output specifications SPST NO relay outputs 250 VAC 2 A resistive load Electrical life 100 000 operations Minimum applicable load 10 mA at 5 V reference value Event inputs Number of inputs 1 depends on model External contact input specifications Contact input ON 1 kΩ max OFF 100 kΩ min Non contact input ON Residual voltage 1 5 V max OF...

Page 43: ...erature sensor Sensor specifica tion Pt100 JPt100 K J T E L U N R S B C W PLII 10 to 70 C 60 to 120 C 115 to 165 C 140 to 260 C 2300 1800 1700 1600 1500 1400 1300 1200 1100 1000 900 800 700 600 500 400 300 200 100 100 200 2300 1800 1700 1700 1300 1300 1300 850 850 850 600 500 0 500 0 500 0 400 0 400 400 0 400 400 0 260 120 165 100 0 100 0 90 100 0 0 0 0 0 0 0 0 0 0 0 0 20 0 100 20 0 100 200 199 9 ...

Page 44: ...y sequence A standby sequence is added to the lower limit alarm 3 6 8 Absolute value upper lim it The alarm will turn ON if the process value is larger than the alarm value X regardless of the set point 9 Absolute value lower limit The alarm will turn ON if the process value is smaller than the alarm value X regardless of the set point 10 Absolute value upper lim it with standby sequence A standby...

Page 45: ...er to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the operation of the standby sequence 7 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the LBA 8 Refer to the E5 C Digital Temperature Controllers User s Manual Cat No H174 for information on the PV change rate alarm 9 When heating cooling control is performed...

Page 46: ...digit max Other thermocouple 1 of PV or 4 C whichever is greater 1 digit max 4 Input sampling period 50 ms Hysteresis Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 01 to 99 99 FS in units of 0 01 FS Proportional band P Temperature input 0 1 to 999 9 C or F in units of 0 1 C or F Analog input 0 1 to 999 9 FS in units of 0 1 FS Integral time I 0 to 9999 s in units of 1 ...

Page 47: ...nction None Communications buffer 217 bytes Communications response wait time 0 to 99 ms Default 20 ms Program less communi cations 1 You can use the memory in the PLC to read and write E5 C parameters start and stop operation etc The E5 C automatically performs communications with the PLC No communications programming is required Number of connected Digital Temperature Controllers 32 max Up to 16...

Page 48: ...12 2 5 6 9 10 11 Sensor Temperature Analog Input Auxiliary output 2 Auxiliary output 1 Control Output 1 linear current output 1 relay output 1 voltage output for driving SSR Input Power Supply no polarity 100 to 240 VAC 24 VAC DC Auxiliary Outputs Control output Relay output 250 VAC 3 A resistive load Voltage output for driving SSR 12 VDC 21 mA Linear current output 0 to 20 mA DC Load 500 Ω max 4 ...

Page 49: ...5DC 800 22 7 0 3 0 120 min Mounted Separately Two Unit Mounting Group Mounted 92 0 8 0 45 0 6 0 92 0 8 0 92 0 8 0 22 5 number of units 1 0 0 96 110 91 85 81 35 22 5 22 5 4 4 Mounting Adapter Accessory Sold separately E5DC 800 Recommended panel thickness is 1 to 8 mm Group mounting is not possible in the vertical direction Maintain the specified mounting space between Controllers When two or more D...

Page 50: ...tage Eo Reference Values E54 CT1 or E54 CT1L Maximum continuous heater current 50 A 50 60 Hz Number of windings 400 2 Winding resistance 18 2 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 100Ω RL 10Ω 10 1 100mV 10 1 100μV 10 1kΩ Output voltage Eo V r m s E54 CT1L 5 8 dia Filler epoxy Case PBT Shrinkable tube Two 3 5 dia Cable AWG18 25 2 5 115 5 ...

Page 51: ...or E54 CT3L Maximum continuous heater current 120 A 50 60 Hz Maximum continuous heater current for an OMRON Digital Temperature Controller is 50 A Number of windings 400 2 Winding resistance 8 0 8 Ω Thru current Io A r m s 1 10 100mA 1 10 100 1 000A 100V Frequency 50 Hz Distortion factor 10 3 1 1kΩ 100Ω 50Ω RL 10Ω 500Ω 10 1 100mV 10 1 100μV 10 Output voltage Eo V r m s Filler epoxy Case PBT Cable ...

Page 52: ...roduct to connect between terminals for power supplies communications etc when you use multiple E5DC 800 Controllers 50 11 5 10 M4 8 pan head screw M4 spring washer 4 8 1 3 1 8 1 10 6 2 1 8 35 5 35 3 4 5 15 25 25 10 10 1000 500 25 25 15 5 35 0 3 7 3 0 15 27 0 15 1 Dimensions in parentheses are for the PFP 50N 5 16 12 44 3 34 8 16 5 The Unit Labels for the Digital Panel Meter are used Use either th...

Page 53: ...MEMO 53 ...

Page 54: ...basic settings Used to set communications Used for SP alarm values and other basic settings and monitoring Used to change adjustment parameters PID constants adjustment sensitivity etc Used to set protection for operations Press the O Key for at least 1 s Press the O and M Keys for at least 1 s Press the O and M Keys for at least 3 s 2 Press the O Key for at least 3 s 2 S Key for at least 1 s 1 Pr...

Page 55: ...ontinues and operation is normal The value will appear in the display for the PV Refer to the E5 C Digital Controllers User s Manual Cat No H174 for information on the controllable range Above 9 999 e333 A D converter error There is an error in the internal circuits First cycle the power supply If the display remains the same the controller must be repaired If the display is restored to normal the...

Page 56: ...esis Cooling Soak Time Wait Band MV at Stop MV at PV Error SP Ramp Set Value MV Upper Limit MV Lower Limit MV Change Rate Limit Work Bit 1 ON Delay Work Bit 2 ON Delay Work Bit 3 ON Delay Work Bit 4 OFF Delay Work Bit 5 ON Delay Work Bit 6 ON Delay Work Bit 7 ON Delay Work Bit 8 ON Delay Work Bit 1 OFF Delay Work Bit 2 OFF Delay Work Bit 3 OFF Delay Work Bit 4 ON Delay Work Bit 5 OFF Delay Work Bi...

Page 57: ...Transfer Output Type Transfer Output Upper Limit Transfer Output Lower Limit Event Input Assignment 1 Event Input Assignment 2 Extraction of Square Root Enable Move to Advanced Function Setting Level Displayed when initial setting communications protect is set to 0 Move by setting password 169 Parameter Initialization Number of Multi SP Points SP Ramp Time Unit Standby Sequence Reset Auxiliary Out...

Page 58: ...nal Unit If corroded terminals are used contact failure in the terminals may cause the temperature inside the Digital Controller to increase possibly resulting in fire If the terminals are corroded replace the Terminal Unit as well Tighten the terminal screws to the rated torque of between 0 43 and 0 58 N m 4 Loose screws may occasionally result in fire Set the parameters of the product so that th...

Page 59: ... two seconds of turning ON the power using a switch or relay contact If the voltage is applied gradually the power may not be reset or output malfunctions may occur 11 Make sure that the Digital Temperature Controller has 30 minutes or more to warm up after turning ON the power before starting actual control operations to ensure the correct temperature display 12 When executing self tuning for the...

Page 60: ...ontrollers with Push In Plus Terminal Blocks on page 64 Do not wire anything to the release holes Do not tilt or twist a flat blade screwdriver while it is inserted into a release hole on the terminal block The terminal block may be damaged Insert a flat blade screwdriver into the release holes at an angle The terminal block may be damaged if you insert the screwdriver straight in Do not allow the...

Page 61: ...the product so that it is horizontally level 4 If the measurement accuracy is low check to see if input shift has been set correctly Waterproofing Not applicable to the E5CC U 800 E5DC 800 The degree of protection is as shown below Sections without any specification on their degree of protection or those with IP 0 are not waterproof Front panel IP66 Rear case IP20 Terminal section IP00 When waterp...

Page 62: ...ten the two fastening screws on the Adapter Alternately tighten the two screws little by little to maintain a balance Tighten the screws to a torque of 0 29 to 0 39 N m Mounting to and Removing from DIN Track E5DC 800 Mounting a Unit Pull down the DIN Track hook on the Terminal Unit and catch the top hook on the DIN Track Press the Unit onto the DIN Track until the DIN Track hooks are locked in pl...

Page 63: ...e holes on the top and bottom of the Digital Temperature Controller E5EC E5AC 800 Slightly bend the E53 COV24 Terminal Cover to attach it to the terminal block as shown in the following diagram The Terminal Cover cannot be attached in the opposite direction Attaching the End Cover E5DC 800 1 Install the E5DC 800 in a panel 2 Peel off the release paper from the double sided tape on the End Cover 3 ...

Page 64: ...ew Terminal Blocks use the following of crimp terminals for M3 screws For the E5CC U 800 use the following types of crimp terminals for M3 5 screws If you use crimp terminals for the E5DC 800 use crimp terminals with insulation sleeves If you use a bare crimp terminal with no insulation the terminal may short with the terminal above or below it If you use bare crimp terminals cover the crimped sec...

Page 65: ...e hole 2 With the flat blade screwdriver still inserted into the release hole remove the wire from the terminal insertion hole 3 Remove the flat blade screwdriver from the release hole 3 Recommended Ferrules and Crimp Tools Recommended ferrules Note 1 Make sure that the outer diameter of the wire coating is smaller than the inner diameter of the insulation sleeve of the recommended ferrule 2 Make ...

Page 66: ...MEMO 66 ...

Page 67: ... CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product i...

Page 68: ...ON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 Contact www ia omron com Kyoto JAPAN OMRON TAIWAN ELECTRONICS INC 6F Home Young Budg No 363 Fu Shing N Road Taip...

Reviews: