![background image](http://html1.mh-extra.com/html/omron/e3zm/e3zm_datasheet_741219005.webp)
A-5
E3ZM
E3ZM
Rating and Specifications
Sensor method
BGS Reflective Models
Model NPN output
E3ZM-LS61H
E3ZM-LS66H
E3ZM-LS62H
E3ZM-LS67H
E3ZM-LS64H
E3ZM-LS69H
Item
PNP output
E3ZM-LS81H
E3ZM-LS86H
E3ZM-LS82H
E3ZM-LS87H
E3ZM-LS84H
E3ZM-LS89H
Sensing distance
10 to 100 mm
(White paper 100 × 100 mm)
10 to 150 mm
(White paper 100 × 100 mm)
10 to 200 mm
(White paper 100 × 100 mm)
Spot Diameter (typical)
4 mm dia. at sensing distance
of 100 mm
12 mm dia. at sensing distance
of 150 mm
18 mm dia. at sensing distance
of 200 mm
Standard sensing object
---
Differential travel
3% of sensing distance max.
15% of sensing distance max.
20% of sensing distance max.
Black/white error
5% of sensing distance max.
10% of sensing distance max.
20% of sensing distance max.
Directional angle
---
Light source (wave length)
Red LED (650 nm)
Red LED (660 nm)
Power supply voltage
10 to 30 VDC, including 10% ripple (p-p)
Current consumption
25 mA max.
Control output
Load power supply voltage: 30 VDC max., Load current: 100 mA max. (Residual voltage: 2 V max.)
Open-collector output (NPN/PNP output depending on model)
Light-ON/Dark-ON cable connection selectable
Protection circuits
Reversed power supply polarity protection, Output short-circuit protection, Reversed output polarity
protection, Mutual interference protection
Response time
Operate or reset: 1 ms max.
Sensitivity adjustment
---
Ambient illumination
(Receiver side)
Incandescent lamp: 3,000 lx max. Sunlight 10,000 lx max.
Ambient temperature range
Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)
Insulation resistance
20 M
Ω
min. at 500 VDC
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
Degree of protection *1
*1. IP69K Degree of Protection Specification
*2. IP69K is a protection standard against high temperature and high-pressure water defined in the German standard DIN 40050,
*3. Part 9.The test piece is sprayed with water at 80°C at a water pressure of 80 to 100 BAR using a specified nozzle shape.
*4. The distance between the test piece and nozzle is 10 to 15 cm, and water is sprayed horizontally for 30 seconds
*5. each at 0°, 30°, 60°, and 90° while rotating the test object on a horizontal plane.
IEC: IP67, DIN 40050-9: IP69K
Connection method
Pre-wired cable (standard length: 2 m)
Standard M8 4-pin Connector
Indicator
Operation indicator (yellow), Stability indicator (green)
Weight
(packed
state)
Pre-wired cable
Approx. 90 g
Standard
Connector
Approx. 40 g
Materials
Case
SUS316L
Lens
Methacrylic resin
Display
PES (polyether sulfone)
Sensitivity
adjustment and
operation switch
PEEK (polyether ether ketone)
Seals
Fluoro rubber
Accessories
Instruction sheet (Note: Mounting Brackets are sold separately.)