background image

E3X-NV/NVG

E3X-NV/NVG

5

REMOTE TEACHING

Remote Teach Function

In principle, the remote teach function of the E3X-NV

 should be used for initial teaching. Basically, the method of remote teaching is the same

as that of sensitivity setting. In remote teaching, instead of pressing the teach button, teach is performed with a remote teach input signal.

1. Set the mode selector to RUN.

2. The following signal conditions must be given as remote teaching input conditions.

3. If remote teaching is not performed, cut the pink wire at the base or connect the pink wire to the +V terminal.

4. After the remote teaching input setting is finished, the E3X-NV

 will be ready to detect objects in approximately one second.

Brown +V

Black
Control output

Pink

Blue 0 V

Power supply

ON

OFF

Remote teach input

With/Without-object teaching

H

L

T

1

T

2

T

1

T

1:

 0.5 to 2 s

T

2:

 3 s min.

Maximum sensitivity setting

H

L

T

3

T

3

: 5 s min.

No-object teaching

H

L

T

4

T

5

T

4

T

4:

 0.5 to 2 s

T

5:

 1.5 to 2 s

OPTICAL AXIS ADJUSTMENT (FLASHING FUNCTION)

Set the mode selector of the E3X-NV

 to TEACH. The  flashing function of E3X-NV

 will be activated. When the optical axes of the fiber heads

are divergent and the light value decreases by approximately 10% of the maximum value, the tip of the emitting fiber will start flashing and the
built-in buzzer will beep. At this time, if the optical axes are divergent, adjust the axes. The peak light value will be memorized by the E3X-NV

.

Do not press the teach button before or while adjusting the optical axes, or the flashing function will not operate.

Fiber for light emission

Fiber for light reception

Light reception

The peak of light reception
90% of the peak value

Lit in this range.

Angle of the head (

θ

)

Flashing

Lit

Flashing

θ

Summary of Contents for E3X-NV

Page 1: ...Object Teaching capability speeds setup Rated IP66 can withstand light washdown Remote teach function allows easy remote teaching from the controller Mounts on DIN rail track Uses E32 series fiber opt...

Page 2: ...or no light Teaching function Remote input Remote input is ON when pink and blue wires short circuited Remote input is OFF when pink and blue wires are not shorted Confirmation Red green LED indicator...

Page 3: ...black terminals Between brown and black terminals Operation indicator orange Output transistor Load relay E3X NV21 NVG21 Incident Interrupted ON OFF ON OFF Operates Releases WITH WITHOUT OBJECT TEACHI...

Page 4: ...ng level to 10 of the light level The light value decreases and the photoelectric sensor works in through beam operation Operating level 10 10 Light Light Change to RUN mode 3 Detectable objects conti...

Page 5: ...N OFF Remote teach input With Without object teaching H L T1 T2 T1 T1 0 5 to 2 s T2 3 s min Maximum sensitivity setting H L T3 T3 5 s min No object teaching H L T4 T5 T4 T4 0 5 to 2 s T5 1 5 to 2 s OP...

Page 6: ...98 59 2 32 9 0 35 11 0 43 0 16 22 5 0 89 13 0 51 16 0 63 37 1 46 22 5 0 89 3 4 2 0 08 16 0 63 6 0 24 3 9 0 15 0 4 12 5 0 49 8 4 0 33 8 0 31 4 59 12 33 2 Installation CONNECTION Connection with S3D2 Se...

Page 7: ...sconnection Push up the lock lever so that the fiber optic cable can be removed To avoid damage make sure that the fiber is unlocked before re moving AMPLIFIER Mounting 1 Mount the front part on the m...

Page 8: ...sing the teaching button on the Amplifier Unlike experiencing teaching errors if any memory error occurs red green teaching indicators will flash simultaneously and opera tion indicators and stability...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron E39 L48...