background image

E3X-NV/NVG

E3X-NV/NVG

4

NO-OBJECT TEACHING WITH AN INITIAL OPERATING LEVEL COMPENSATION FUNCTION

With Diffuse (Light-ON) Fiber

1. Teaching button is pressed once.

2. The first detectable object is in the detectable area.

3. Detectable objects continue to pass through the sensing area.

Operating level

10%

ON

OFF

0

Large

Small

Operating level

Set the operating level to

±

10% of the light level.

Operating level

Large

Small

0

Light level of
background

The light level increases and the
photoelectric sensor works in re-
flective operation.

10%

10%

Considering the detectable object positions and the color differences
of detectable objects, sample the light of the first to fifth objects. Then
reset the operating level to the median value between the lowest light
with a detectable object and the light without a detectable object.

Large

Small

0

(1)

(2)

(3)

(4)

(5)

(6)

Resetting

Operating level

Light

Light

Light

Note:

If the light value up to the fifth object is at least twice
as large as the operating level, the initial set operat-
ing level (10%) will be maintained.

Change to
RUN mode

With Through-beam (Dark-ON) Fiber Unit

1. Teaching button is pressed once.

2. The first detectable object is in the sensing area.

0

0

Large

Small

Operating level

Operating level

10%

ON

OFF

Large

Small

Light level with
no object

Set the operating level to

±

10% of the light level.

The light value decreases and
the photoelectric sensor works
in through-beam operation.

Operating level

10 %

10 %

Light

Light

Change to
RUN mode

3. Detectable objects continue to pass through the sensing area.

Large

Small

0

(1)

(2)

(3)

(4)

(5)

(6)

Considering a drop in light value due to optical axis divergence or dust
on the lenses, sample the light of the first to fifth objects. Then reset the
operating level to the median value between the lowest light with a de-
tectable object and the light without detectable object.

Resetting

Operating level

Light

Note:

1. After no-object teaching, when the E3X-NV

 is turned off and on, the operation level will be set to the +10% of the initial light

level (refer to the above (1)) in reflective operation and –10% of the initial light level in through-beam operation and stand by.

2. After performing no-object teaching and changing to RUN mode, until the first detectable object is in the sensing area, the control

output will be prohibited (OFF). The control output will be determined when the first detectable object is detected.

3. The initial operating level compensation function will operate after teaching and/or after the E3X-NV

 is turned on.

4. During no-object teaching, after the E3X-NV

 is in RUN mode, the E3X-NV

 requires approximately 60 ms to determine the oper-

ating level from the time the first detectable object is in the sensing area. After the operating level is determined, the E3X-NV

 will

operate with a normal response speed of 500 

µ

s.

Summary of Contents for E3X-NV

Page 1: ...Object Teaching capability speeds setup Rated IP66 can withstand light washdown Remote teach function allows easy remote teaching from the controller Mounts on DIN rail track Uses E32 series fiber opt...

Page 2: ...or no light Teaching function Remote input Remote input is ON when pink and blue wires short circuited Remote input is OFF when pink and blue wires are not shorted Confirmation Red green LED indicator...

Page 3: ...black terminals Between brown and black terminals Operation indicator orange Output transistor Load relay E3X NV21 NVG21 Incident Interrupted ON OFF ON OFF Operates Releases WITH WITHOUT OBJECT TEACHI...

Page 4: ...ng level to 10 of the light level The light value decreases and the photoelectric sensor works in through beam operation Operating level 10 10 Light Light Change to RUN mode 3 Detectable objects conti...

Page 5: ...N OFF Remote teach input With Without object teaching H L T1 T2 T1 T1 0 5 to 2 s T2 3 s min Maximum sensitivity setting H L T3 T3 5 s min No object teaching H L T4 T5 T4 T4 0 5 to 2 s T5 1 5 to 2 s OP...

Page 6: ...98 59 2 32 9 0 35 11 0 43 0 16 22 5 0 89 13 0 51 16 0 63 37 1 46 22 5 0 89 3 4 2 0 08 16 0 63 6 0 24 3 9 0 15 0 4 12 5 0 49 8 4 0 33 8 0 31 4 59 12 33 2 Installation CONNECTION Connection with S3D2 Se...

Page 7: ...sconnection Push up the lock lever so that the fiber optic cable can be removed To avoid damage make sure that the fiber is unlocked before re moving AMPLIFIER Mounting 1 Mount the front part on the m...

Page 8: ...sing the teaching button on the Amplifier Unlike experiencing teaching errors if any memory error occurs red green teaching indicators will flash simultaneously and opera tion indicators and stability...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Omron E39 L48...

Reviews: