background image

E3X-NA

User-Friendly Fiber-Optic Amplifier

Solve Your Basic Sensing Challenges
Easily with the E3X-NA Series

Streamlined features provide basic sensing
immediately after plug-in

Wire-saving amplifiers reduce installation
time and minimize space requirements

Master/slave connector design affords
connectivity for up to 16 wire-saving
amplifiers

Use the LED bar display to quickly confirm
sensor performance

Optical communication design prevents
mutual interference for up to 5 amplifiers

Green LED models address

mark-detecting

applications

High-speed models have a response time
of 50

µ

s

Select a

water-resistant model (IP66 rating)

using an M8 connector

Prewired water-resistant models are available

Ordering Information:
Amplifier Units, Connectors, Accessories and Fiber-Optics

Amplifier Units with Cables

Type

Part number

Control output

Appearance

NPN output

PNP output

Standard

E3X-NA11

E3X-NA41

ON/OFF

High-speed

E3X-NA11F

E3X-NA41F

Mark-detection

E3X-NAG11

E3X-NAG41

Water-resistant

E3X-NA11V

E3X-NA41V

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Summary of Contents for E3X-NA -

Page 1: ...gn prevents mutual interference for up to 5 amplifiers Green LED models address mark detecting applications High speed models have a response time of 50 s Select a water resistant model IP66 rating us...

Page 2: ...tions Appearance Cable type Part number M8 Standard cable Straight connector 2 m Four core cable XS3F M421 402 A 5 m XS3F M421 405 A L shaped connector 2 m XS3F M422 402 A 5 m XS3F M422 405 A Amplifie...

Page 3: ...t 20 000 lux max Ambient temperature Operating Groups of 1 to 3 Amplifiers 25 C to 55 C 13 F to 131 F Groups of 4 to11 Amplifiers 25 C to 50 C 13 F to 122 F Groups of 12 to16 Amplifiers 25 C to 45 C 1...

Page 4: ...cators 4 green and 1 red Use these indicators for optical axis adjustments and maintenance Note The indicator farthest to the right will be lit even if the incident level is 0 Status of indicators in...

Page 5: ...or orange Output transistor Load relay Operate Release Between brown and black T ON ON OFF OFF Incident light No incident light Operation indicator orange Output transistor Load relay Operate Release...

Page 6: ...0 50 100 150 200 0 2 0 4 0 6 0 8 1 X Y X Y X Y E32 T11 E32 T24S Distance Y mm Distance Y mm Distance X m E3X NAG E3X NA F E3X NA V Distance Y mm Distance X mm E3X NAG E3X NA F E3X NA V E32 TC200E Dis...

Page 7: ...umber of turns Number of t 1 2 1 0 0 8 0 6 0 4 0 2 0 2 4 6 8 10 400 300 200 100 0 2 4 6 8 10 E3X NA V E3X NA F E3X NA V F 100 80 60 40 20 0 100 200 300 400 500 600 700 20 15 10 5 0 50 100 150 200 E32...

Page 8: ...area 0 45 mm 2 insulation diameter 1 1 mm is used Standard length 2 m 8 10 7 10 0 39 3 64 3 2 53 38 6 31 5 1 24 9 9 5 3 3 4 22 4 16 4 4 4 1 13 34 8 2 4 22 4 16 4 10 75 16 15 75 9 2 E3X NA11 E3X NA11F...

Page 9: ...Connected E3X CN11 4 0 dia E3X CN12 2 6 dia 1 5 31 5 1 24 1 8 5 1 3 9 12 95 4 10 0 39 64 3 67 5 71 2 80 64 3 67 5 71 2 80 1 5 31 5 1 8 5 1 3 9 3 4 8 12 95 11 55 17 45 4 10 0 39 1 24 6 9 81 5 3 21 12...

Page 10: ...al area 0 2 mm2 insulation diameter 1 1 mm is used See note 4 dia 14 4 2 6 6 2 9 10 0 8 8 4 6 8 10 7 50 5 0 30 2 10 2 4 15 1 6 2 m 6 56 ft Slave Connectors E3X CN12 Note A 2 6 dia single conductor vin...

Page 11: ...Stainless steel SUS 304 7 3 4 1 3 16 3 7 10 3 7 3 5 3 10 3 2 5 34 8 1 37 22 16 26 8 3 3 4 1 16 0 1 E39 L148 12 1 5 9 1 9 3 4 2 R1 7 R1 7 2 16 27 3 4 3 4 3 7 3 35 1 38 22 3 4 16 9 5 16 0 1 Two 3 2 dia...

Page 12: ...nted side by side The E3X MC11 Mobile Console sold separately cannot be used If an excessive amount of light is received via the Sensor the mutual interference prevention function may not work In this...

Page 13: ...of the Amplifier Unit onto the mounting bracket or the DIN rail first or the mounting strength of the Amplifier Unit may be reduced Always mount the front of the Amplifier Unit first Removal Pull the...

Page 14: ...be reduced Always use an unused hole Cut a thin fiber as follows 1 An attachment is temporarily fitted to a thin fiber before ship ment 2 Secure the attachment after adjusting the position of it in th...

Page 15: ...into the Amplifier Unit until it clicks into place 2 Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted 3 Attach the stickers provided as accessorie...

Page 16: ...o the Protective Spiral Tube from the head connec tor side screwed of the tube Push the fiber into the Protective Spiral Tube The tube should be straight so that the fiber is not twisted when inserted...

Page 17: ...ible to mount the reflective side view conversion attachment E39 F5 E3X NA V 1 0 mm dia 0 03 mm dia 25 mm E3X NAG E3X NA F 1 0 mm dia 0 2 mm dia M3 for detecting minute sensing targets E3X NA V 0 5 mm...

Page 18: ...table for detecting minute sensing targets E3X NA V 0 5 mm dia 0 03 mm dia 10 mm E3X NAG E3X NA F 0 5 mm dia 0 3 mm dia Suitable for detecting minute sensing targets E3X NA V 0 5 mm dia 0 03 mm dia E3...

Page 19: ...ia 0 5 mm dia Side view resists 150 C 2 suitable for detecting minute sensing targets fiber sheath material fluororesin operating ambient temper ature 40 C to 150 C E3X NA V 1 0 mm dia 0 03 mm dia 35...

Page 20: ...4 Detects in a 30 mm area flexible E3X NA V 0 5 mm dia 4 1 mm E3X NA F 4 0 mm dia 4 Side view suitable for applica tions with limited spatial depth E3X NA V 0 3 mm dia 4 10 mm E3X NAG E3X NA F 2 0 mm...

Page 21: ...small diameter E3X NA V 50 50 0 01 mm dia 10 mm E3X NAG 25 25 0 1 mm dia E3X NA F 25 25 0 02 mm dia Thin fiber 2 5 mm dia with sleeve E3X NA V 200 200 0 01 mm dia 25 mm E3X NAG 50 50 0 1 mm dia E3X NA...

Page 22: ...5 25 0 1 mm dia E3X NA F 50 50 0 02 mm dia M3 small diameter E3X NA V 25 25 0 01 mm dia E3X NA F 25 25 0 03 mm dia 3 mm dia small diameter E3X NA V 25 25 0 01 mm dia E3X NA F 25 25 0 03 mm dia Applica...

Page 23: ...dia long distance E3X NA V 50 50 0 03 mm dia 25 mm E3X NAG 25 25 0 3 mm dia E3X NA F 25 25 0 03 mm dia 6 mm dia flexible E3X NA V 25 25 0 03 mm dia 1 mm E3X NA F 2 mm dia small diameter flexible spac...

Page 24: ...ing ambient temper ature 25 C to 55 C enclosure rating IEC 60529 IP66 E3X NA V 35 mm dia 0 6 mm dia 25 mm E3X NA F 35 mm dia 4 0 mm dia Limited reflective Suitable for positioning crystal glass E3X NA...

Page 25: ...25 E3X NA E3X NA Downloaded from Elcodis com electronic components distributor...

Page 26: ...26 E3X NA E3X NA Downloaded from Elcodis com electronic components distributor...

Page 27: ...27 E3X NA E3X NA Downloaded from Elcodis com electronic components distributor...

Page 28: ...d in USA OMRON CANADA INC 885 Milner Avenue Scarborough Ontario M1B 5V8 416 286 6465 OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg IL 60173 1 800 55 OMRON OMRON ON LINE Global http www omro...

Reviews: