background image

E3X-SD/-NA

READ AND UNDERSTAND THIS DOCUMENT

Please read and understand this document before using the products. Please consult your OMRON representative if you have any 

q

uestions or 

comments.

WARRANTY

OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if 
specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT 
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR 
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR 
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, 
NEGLIGENCE, OR STRICT LIABILITY.

In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS 
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND 
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE

THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED.  THEY ARE NOT DESIGNED OR RATED FOR ENSURING 
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH 
PURPOSES.  Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the 
customer’s application or use of the product.

At the customer’s re

q

uest, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply 

to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end 
product, machine, system, or other application or use.

The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all 
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical e

q

uipment, amusement machines, vehicles, 

safety e

q

uipment, and installations subject to separate industry or government regulations.

• Systems, machines, and e

q

uipment that could present a risk to life or property.

Please know and observe all prohibitions of use applicable to the products.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT 
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED 
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA

Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may 
represent the result of OMRON’s test conditions, and the users must correlate it to actual application re

q

uirements. Actual performance is subject 

to the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons.

It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. 
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix 
or establish key specifications for your application on your re

q

uest. Please consult with your OMRON representative at any time to confirm actual 

specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS

The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, 
typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any conse

q

uence thereof.

COPYRIGHT AND COPY PERMISSION

This document shall not be copied for sales or promotions without permission.

This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or 
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in 
its entirety.

Summary of Contents for E3X-MDA Series

Page 1: ...E3X SD NA Series NEW Digital Display Direct Key Setting Simple Fiber Amplifiers Bar Display Manual Setting The Series now includes models with digital displays and direct key setting Simplicity and H...

Page 2: ...supply pin Master Connector Slave Connector 1 E3X NA E3X SD A timer function is provided as a standard feature The switch is for the timer only so no complicated operation is required Compact No mode...

Page 3: ...Prevent Mutual Interference for Up to Five Amplifiers 400 mm Standard Fiber Unit E32 TC200 Sufficient distance performance A maximum distance of 14 m can be achieved by using a Long distance Fiber Un...

Page 4: ...A S Standard models E3X DA AN S Easy measurement control using analog output E3X DAC S Color sensing models with white LEDs Stable detection with resistance against workpiece movement NEW NEW Digital...

Page 5: ...splay and Direct Key Setting Bar Display and Adjuster Setting Item Appearance Connection method Ratings and Specifications Model NPN output PNP output Standard models Pre wired E3X SD11 E3X SD41 Wire...

Page 6: ...2 A 5 m XS3F M422 405 A Combining Amplifier Units and Connectors Amplifier Units Applicable Connectors Order Separately Type NPN PNP Master Connector Slave Connector Basically Amplifier Units and Conn...

Page 7: ...lifiers optically synchronized None Up to 5 Amplifiers optical ly synchronized Ambient illumination Receiver side Incandescent lamp 10 000 lux max Sunlight 20 000 lux max Ambient temperature range Ope...

Page 8: ...odels Reflective Fiber Units Size 15 10 3 mm Flat and flexible fiber models are easy to mount and will not break 20 mm Flat View E32 D15ZR Flexible fiber Conventional fiber Cladding Cores No Breaking...

Page 9: ...E32 T11R E39 F1 2100 630 E32 T11 E39 F1 2000 600 E32 T14 1800 540 E32 T11L E32 T12L 700 210 E32 T11L E39 F2 500 150 E32 T11R E39 F2 220 65 E32 T11 E39 F2 360 100 E32 T21L E32 T22L 200 60 Ultracompact...

Page 10: ...E32 D33 10 3 3 E32 D331 1 5 0 5 Coaxial small spot E32 CC200R 75 25 E32 CC200 150 50 E32 D32L 80 25 E32 C31 E32 D32 40 13 E32 C42 E39 F3A Spot diameter of 0 1 to 0 6 mm at 6 to 15 mm E32 D32 E39 F3A S...

Page 11: ...No incident light ON OFF ON OFF Operate Reset Operation indicator orange Between brown and black leads Output transistor Load relay T Incident light No incident light ON OFF ON OFF Operate Reset Oper...

Page 12: ...power supply polarity 7 Connect the load properly 8 Do not short circuit both ends of the load 9 Do not use the product if the case is damaged 10 When disposing of the product dispose of it as indust...

Page 13: ...nnection and Disconnection The E3X Amplifier Unit has a lock lever Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures 1 Connection Open the Protective Co...

Page 14: ...separated press down on the lever on the Connector and remove it Do not attempt to remove Connectors without separating them from other Amplifier Units first Mounting End Plate PFP M Depending on how...

Page 15: ...parately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39 F9 Two M3 Mounting Holes There is no hole f...

Page 16: ...tions Center of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Mounting Bracket E39 L143 SUS304 stainless steel Fiber Attachment mounted E39...

Page 17: ...Insulator diameter 1 1 mm DIN track mounting Two 2 4 dia Center of DIN track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Multiple connection diagram...

Page 18: ...track DIN track sold separately PFP N Fiber Attachment mounted E39 F9 End Plate sold separately PFP M Multiple connection diagram Hole for optical communications Hole for optical communications Mounti...

Page 19: ...sulator diameter 1 1 mm Edge of amplifier Slave Connector E3X CN12 7 2 000 50 0 E3X CN12 2 6 dia 2 6 dia cable 1 conductor 1 conductor Standard length 2 m Conductor cross section 0 2 mm2 AWG24 Insulat...

Page 20: ...0 Unstable incident light or Unstable interrupted light 0 90 max Stable interrupted light Operation description Switch Key Display Set the TEACH RUN selector switch to TEACH Press the UP Key for 3 s m...

Page 21: ...21 MEMO...

Page 22: ...MEMO 22...

Page 23: ...ed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control s...

Page 24: ...e Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 F...