RUN

SET

Teaching

0. Operation Mode

Light-ON

Dark-ON

Switch to SET mode.

1. Detection Mode

Set separately for each channel.

Set separately for each channel.

2. Timer Function

Note: Refer to 7. Basic Settings for teaching methods.

Zero reset

Switch to RUN mode. 

Switch to RUN mode.

Switch to RUN mode.

Switch to RUN mode.

The display will be zeroed, 

i.e., the conformity will be 

displayed as 0.

RUN

SET

RUN

SET

RUN

SET

Press the MODE key for 

3 seconds or more. 

RUN

SET

KeyLock

+

+

+

Light level

Threshold

LOC

ON

LOC

OFF

Standard mode

High-resolution mode

High-speed mode

8. Detailed Settings

9. Convenient Functions

“Light lerel/Threshold”

“TECH/Threshold”are displayed in fixed time.

Super-high-speed mode

Set separately for each channel.
Setting range: 0P to 99P
If the teaching level is small or large, it is set to 
upper or lower of threshold to operate correctly.

Hold down the MODE key and 

press the DOWN key 

for 3 seconds or more. 

Frash twice and the zero 

reset function will be cleared.

The light level displayed on the main display can be zeroed. The threshold displayed in 

the sub-display is shifted by an amount corresponding to the amount the light level was 

changed. Confirm that the MODE key setting is 0RST (zero reset) in advance.

Setting Method

Clearing Method

Key operations can be disabled to help prevent key operating errors.

Setting Method

Clearing Method

Flash twice and key input 

will be enabled.

Flash twice and key input 

will be disabled.

If a key is pressed while key operations are locked, 

"LOC ON" will flash twice on the display to indicate 

that key operations have been disabled.

User Save

RUN

SET

Save has been completed.

Not save

NO?

YES?

Save

Switch to SET mode.

Press the MODE key and  the UP key 

at the same time for 5 seconds or more.

SAVE

NO?

GOOD

Setting Method

+

The current setting can be saved. 

Threshold

GOOD

Threshold

Initial Reset, User Reset

RUN

SET

Initialization has been 

completed.

Not initialized

NO?

YES?

Initialized

Switch to SET mode.

Press the UP key and the DOWN key for 5 seconds or more.

+

INIT

NO?

Setting Method

Initial reset: Initialize all of settings (except user save) to return to the default states. 

User reset: Return to the saved states.

1) When user save is not executed(Initial reset only)

RUN

SET

User reset

USER

INIT

Initial reset

Switch to SET mode.

Press the UP key and the DOWN key for 5 seconds or more.

+

RST

USER

USER

Setting Method

2) When user save is executed(Select initial reset or user reset)

GOOD

Threshold

User reset has been 

completed.

Not execute 

user reset

NO?

YES?

Execute 

user reset

Refer to 1) 

When user save 

is not executed.

NO?

ERR

EEP

10. Error display

If the error occurs, the error messages are blinking as below. 

In these case Execute following procedures to restore.

OVER

CUR

EEPROM error

Execute initial reset operation.

The following functions can be set in SET mode. The function displays are the default 

settings. All settings except for the operation mode, detection mode, timer function, teaching 

level setting and ACT setting are the same for both channels .

: The  values shown for thresholds, light level, ratio, etc., are examples only. Actual displays may vary.

Overcurrent of control output

Check an output load and keep current in rating.

Check whether the load to be short-circuited.

OVER

flash twice

flash twice

LO

Over error

Low error

 Teaching Error

After execute teaching, when the following is displayed on sub digital display, the error 

has occurred. Deal referring to the following. 

The incident light level is too 

large.

After decrease the light level by the power tuning, execute re-teaching.

After adjust the Fiber Unit to decrease the incident light level, 

execute 

re-teaching.

The incident light level is too small.

After setting the detection method at a slower response time, 

execute 

re-teaching.

After adjust the Fiber Unit to increase the incident light level, 

execute 

re-teaching.

Hold down the MODE key 

and press the UP key 

for 3 seconds or more. 

Hold down the MODE key 

and press the UP key 

for 3 seconds or more. 

Press the MODE key

Switch the UP key or DOWN key

0RST

OFF

Setting

Display

Effective set for ATC function

Switch to RUN mode.

RUN

SET

Threshold 

ratio

Light level 

Threshold value

The threshold ratio is adjusted or the threshold is updated by the incident level every about 3 seconds by ATC start.  

Confirm that the MODE key setting is ATC in advance.

ATC

Adjust the threshold ratio 

value with the UP and 

DOWN keys .

The threshold value that was set will 

flash twice.

Press the MODE key at least 3 

seconds.

Setting

Display

AUTO

Threshold 

value

AUTO

Light level

Automatic-teaching(It sets up at move work.)

While continuing pushing a key, the middle of the detected maximum and the minimum value can be 

set up as a threshold. Confirm that the MODE key setting is AUTO in advance.

Pushing the MODE key 

during 3 seconds or more 

It is displayed on a sub digital 

value as AUTO, and the 

sampling of right level is 

effective.

Threshold value will flush twice.

This method cannot be used to set the threshold when the detection method has 

been set to DIFF (differential operation).

Tough mode

Differential operation mode

Operation is according to the change 

in the incident light level.The output 

for channel 2 is always an alarm 

output for the absolute light level.

1-ms increments

1 to 20 ms

5-ms increments

20 to 200 ms

100-ms increments

200 to 1000 ms

1000-ms increments

1000 to 5000 ms

Single edge

Either the rising or falling 

edge is detected.

Double edge

Both the rising and falling 

edge are detected.

250 ms

500 ms

500 ms

1 ms

1 ms

2 ms

10 ms

20 ms

100 ms

200 ms

Single edge

This setting depends on the setting for 

the differential edge selection.

Setting range: 1 to 5,000

Double edge

Not

Not                    ,

Differential 
Edge Selection

Differential 
Response Time

Timer Time

Timer disabled.

OFF-delay timer

ON-delay timer

One-shot timer

----

OFFD

ON-D

1SHT

ONOF

On-delay OFF-delay timer

ON-delay

Timer

OFF-delay

Timer

3. Teaching Level

    Setting

Disable ATC.

ON

OFF

ATC function is effective.

Set separately for each channel.

4. ACT Setting

Not

Maximum power

FULL

Setting range: 100 to 3,900, FULL

The function of the MODE key in RUN mode can be selected.

5. MODE Key 
    Setting

The information displayed in RUN mode can be selected. 

When going to SET mode, this setting will be ignored and 

the incident light level and threshold value will be displayed.

6. Display
      Switch

Light level

PEAK

Light level

Channel

The incident light level 

and the channel.

Light level

Threshold

% light level Threshold

L-PE

D-BT

Detection status

Alternates at 

a fixed interval

PEAK

BOTM

Peak level

Bottom level

The current incident 

light level and the peak 

incident light level.

The incident light level 

and threshold value

The incident light level as a 

percentage of the threshold value 

and the threshold value.

The peak incident level and 

bottom incident level of fixed 

time(2s).

The incidient light peak level 

and no incident light bottom 

level.
Analog bar display. The 

current detection status is 

displayed as an analog bar. 

The bar will lengthen from the 

right as ON status is reached.

Tunes the power.

2-point teaching.

Automatic-teaching.

PTUN

0RST

Executes a zero reset.

2PNT

AUTO

ATC

Executes.

Normal display.

D123

321D

Reversed display.

7. Display 

    Orientation

The function of the output for channel 2 can be selected.

9. Output Setting

The output for channel 1 functions according to the 

detection mode selection.

This setting is not value if DIFF (differential operation) 

is set for the detection method. (The output for channel

2 is always an alarm output for differential operation.)

Output for each channel

2OUT

AREA

Output if level is between the two 

thresholds.

SELF

Self-diagnosis output

Output when the incident light level 

is not stable, i.e., when the light level of 1CH is ±10% of 

the threshold value for 300 ms or longer.

The item that is controlled by the input from an external device 

can be selected.

Through-beam, no-workpiece teaching

THRU

RFCT

Reflective, no-workpiece teaching

2PNT

2-point teaching

AUTO

Automatic teaching

10. External
       Input Setting *

PTUN

Power tuning

0RST

Zero reset

LOFF

Light OFF (The light will remain OFF as 
long as the input is ON.)

ATC

ATC start 

The teaching cannot be executed even.

8. Eco Mode Setting

Effective Pulse Widths

0.1 to 2 s

Executing: 0.1 to 2 s
Clearing: 3 s or longer

Effective ON pulse 
width: 0.1 s min.

Selection

Pulse width

,

,

Effective  pulse 
width: 3 s 

OFF

ECO1

Standard brightness.

Dims the display.

Turns off the display.

ECO2

D

C

D

C

When DIFF is selected for detection method ,ACT 

function is diasabled.

B

A

LON

DON

A

B

STND

HRES

DIFF

SHS

HS

TG

Light level

Light level

Light level

Without the workpiece

ATC-Start is performed at the time of a 
power supply injection.

ON

OFF

Disable counter.

The processing executed when the power supply is turned 

on is selected.

Setting at power

supply ON

PTAT

Power tuning and ATC-Start is performed
at the time of a power supply injection.

The display turns on the key operation when the Eco-mode is effective. 

It returns to the Eco-mode if there is no key operation for ten seconds. 

Not

Maximum power

FULL

Setting range: 100 to 3,900, FULL

Positioning-teaching

It executes it puts on the place where it wants to position workpiece. 

Setting

RUN
mode

Switch to RUN 

mode.

Press the MODE key 

for at least 3 seconds.

Press the MODE key 

for at least 3 seconds.

Workpiece

RUN

SET

Workpiece

Refer to 

2-point teaching for SET mode and display.

OMRON Corporation

Suitability for Use

EUROPE

OMRON EUROPE B.V. Sensor Business Unit

Carl-Benz Str.4, D-71154 Nufringen Germany

Phone:49-7032-811-0  Fax: 49-7032-811-199
NORTH AMERICA

OMRON ELECTRONICS  LLC

One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.

Phone:1-847-843-7900  Fax : 1-847-843-7787
ASIA-PACIFIC

OMRON ASIA PACIFIC PTE. LTD.

No. 438A Alexandra Road #05-05-08(Lobby 2),

Alexandra Technopark, Singapore 119967 

Phone : 65-6835-3011  Fax :65-6835-2711

o

THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.  
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF 
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY 
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.

OMRON shall not be responsible for conformity with any standards, codes, or 
regulations that apply to the combination of the products in the customer's 
application or use of the product. 
 
Take all necessary steps to determine the suitability of the product for the 
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING 
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE 
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND 
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL 
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.

CHINA

OMRON(CHINA) CO., LTD. 

Room 2211, Bank of China Tower,

200 Yin Cheng Zhong Road, 

PuDong New Area, Shanghai, 200120, China

Phone : 86-21-5037-2222  Fax :86-21-5037-2200

OCT, 2009

LOC

ON

Write results to EEPROM.

ON

OFF

Do not write results to EEPROM.

Whether external input execution results are written 

to EEPROM can be selected. Disable this function 

if the external input is turned ON frequently. 

(The write life is approximately 100000 writes.)

11. External Input 

     Memory *

* The external input cannot be used though it is displayed 

   even by the wire-saving connector