RUN
SET
Teaching
0. Operation Mode
Light-ON
Dark-ON
Switch to SET mode.
1. Detection Mode
Set separately for each channel.
Set separately for each channel.
2. Timer Function
Note: Refer to 7. Basic Settings for teaching methods.
Zero reset
Switch to RUN mode.
Switch to RUN mode.
Switch to RUN mode.
Switch to RUN mode.
The display will be zeroed,
i.e., the conformity will be
displayed as 0.
RUN
SET
RUN
SET
RUN
SET
Press the MODE key for
3 seconds or more.
RUN
SET
KeyLock
+
+
+
Light level
Threshold
LOC
ON
LOC
OFF
Standard mode
High-resolution mode
High-speed mode
8. Detailed Settings
9. Convenient Functions
“Light lerel/Threshold”
⇔
“TECH/Threshold”are displayed in fixed time.
Super-high-speed mode
Set separately for each channel.
Setting range: 0P to 99P
If the teaching level is small or large, it is set to
upper or lower of threshold to operate correctly.
Hold down the MODE key and
press the DOWN key
for 3 seconds or more.
Frash twice and the zero
reset function will be cleared.
The light level displayed on the main display can be zeroed. The threshold displayed in
the sub-display is shifted by an amount corresponding to the amount the light level was
changed. Confirm that the MODE key setting is 0RST (zero reset) in advance.
■
Setting Method
■
Clearing Method
Key operations can be disabled to help prevent key operating errors.
■
Setting Method
■
Clearing Method
Flash twice and key input
will be enabled.
Flash twice and key input
will be disabled.
If a key is pressed while key operations are locked,
"LOC ON" will flash twice on the display to indicate
that key operations have been disabled.
User Save
RUN
SET
Save has been completed.
Not save
NO?
YES?
Save
Switch to SET mode.
Press the MODE key and the UP key
at the same time for 5 seconds or more.
SAVE
NO?
GOOD
■
Setting Method
+
The current setting can be saved.
Threshold
GOOD
Threshold
Initial Reset, User Reset
RUN
SET
Initialization has been
completed.
Not initialized
NO?
YES?
Initialized
Switch to SET mode.
Press the UP key and the DOWN key for 5 seconds or more.
+
INIT
NO?
■
Setting Method
Initial reset: Initialize all of settings (except user save) to return to the default states.
User reset: Return to the saved states.
1) When user save is not executed(Initial reset only)
RUN
SET
User reset
USER
INIT
Initial reset
Switch to SET mode.
Press the UP key and the DOWN key for 5 seconds or more.
+
RST
USER
USER
■
Setting Method
2) When user save is executed(Select initial reset or user reset)
GOOD
Threshold
User reset has been
completed.
Not execute
user reset
NO?
YES?
Execute
user reset
Refer to 1)
When user save
is not executed.
NO?
ERR
EEP
10. Error display
If the error occurs, the error messages are blinking as below.
In these case Execute following procedures to restore.
OVER
CUR
EEPROM error
Execute initial reset operation.
The following functions can be set in SET mode. The function displays are the default
settings. All settings except for the operation mode, detection mode, timer function, teaching
level setting and ACT setting are the same for both channels .
*
: The values shown for thresholds, light level, ratio, etc., are examples only. Actual displays may vary.
Overcurrent of control output
Check an output load and keep current in rating.
Check whether the load to be short-circuited.
OVER
flash twice
flash twice
LO
Over error
Low error
■
Teaching Error
After execute teaching, when the following is displayed on sub digital display, the error
has occurred. Deal referring to the following.
The incident light level is too
large.
・
After decrease the light level by the power tuning, execute re-teaching.
・
After adjust the Fiber Unit to decrease the incident light level,
execute
re-teaching.
The incident light level is too small.
・
After setting the detection method at a slower response time,
execute
re-teaching.
・
After adjust the Fiber Unit to increase the incident light level,
execute
re-teaching.
Hold down the MODE key
and press the UP key
for 3 seconds or more.
Hold down the MODE key
and press the UP key
for 3 seconds or more.
Press the MODE key
Switch the UP key or DOWN key
0RST
OFF
Setting
Display
Effective set for ATC function
Switch to RUN mode.
RUN
SET
Threshold
ratio
Light level
Threshold value
The threshold ratio is adjusted or the threshold is updated by the incident level every about 3 seconds by ATC start.
Confirm that the MODE key setting is ATC in advance.
ATC
Adjust the threshold ratio
value with the UP and
DOWN keys .
The threshold value that was set will
flash twice.
Press the MODE key at least 3
seconds.
Setting
Display
AUTO
Threshold
value
AUTO
Light level
⑥
Automatic-teaching(It sets up at move work.)
While continuing pushing a key, the middle of the detected maximum and the minimum value can be
set up as a threshold. Confirm that the MODE key setting is AUTO in advance.
Pushing the MODE key
during 3 seconds or more
It is displayed on a sub digital
value as AUTO, and the
sampling of right level is
effective.
Threshold value will flush twice.
This method cannot be used to set the threshold when the detection method has
been set to DIFF (differential operation).
Tough mode
Differential operation mode
Operation is according to the change
in the incident light level.The output
for channel 2 is always an alarm
output for the absolute light level.
1-ms increments
1 to 20 ms
5-ms increments
20 to 200 ms
100-ms increments
200 to 1000 ms
1000-ms increments
1000 to 5000 ms
Single edge
Either the rising or falling
edge is detected.
Double edge
Both the rising and falling
edge are detected.
250 ms
500 ms
500 ms
1 ms
1 ms
2 ms
10 ms
20 ms
100 ms
200 ms
Single edge
This setting depends on the setting for
the differential edge selection.
Setting range: 1 to 5,000
Double edge
Not
Not ,
Differential
Edge Selection
Differential
Response Time
Timer Time
Timer disabled.
OFF-delay timer
ON-delay timer
One-shot timer
----
OFFD
ON-D
1SHT
ONOF
On-delay OFF-delay timer
ON-delay
Timer
OFF-delay
Timer
3. Teaching Level
Setting
Disable ATC.
ON
OFF
ATC function is effective.
Set separately for each channel.
4. ACT Setting
Not
Maximum power
FULL
Setting range: 100 to 3,900, FULL
The function of the MODE key in RUN mode can be selected.
5. MODE Key
Setting
The information displayed in RUN mode can be selected.
When going to SET mode, this setting will be ignored and
the incident light level and threshold value will be displayed.
6. Display
Switch
Light level
PEAK
Light level
Channel
The incident light level
and the channel.
Light level
Threshold
% light level Threshold
L-PE
D-BT
Detection status
Alternates at
a fixed interval
PEAK
BOTM
Peak level
Bottom level
The current incident
light level and the peak
incident light level.
The incident light level
and threshold value
The incident light level as a
percentage of the threshold value
and the threshold value.
The peak incident level and
bottom incident level of fixed
time(2s).
The incidient light peak level
and no incident light bottom
level.
Analog bar display. The
current detection status is
displayed as an analog bar.
The bar will lengthen from the
right as ON status is reached.
Tunes the power.
2-point teaching.
Automatic-teaching.
PTUN
0RST
Executes a zero reset.
2PNT
AUTO
ATC
Executes.
Normal display.
D123
321D
Reversed display.
7. Display
Orientation
The function of the output for channel 2 can be selected.
9. Output Setting
The output for channel 1 functions according to the
detection mode selection.
This setting is not value if DIFF (differential operation)
is set for the detection method. (The output for channel
2 is always an alarm output for differential operation.)
Output for each channel
2OUT
AREA
Output if level is between the two
thresholds.
SELF
Self-diagnosis output
Output when the incident light level
is not stable, i.e., when the light level of 1CH is ±10% of
the threshold value for 300 ms or longer.
The item that is controlled by the input from an external device
can be selected.
Through-beam, no-workpiece teaching
THRU
RFCT
Reflective, no-workpiece teaching
2PNT
2-point teaching
AUTO
Automatic teaching
10. External
Input Setting *
PTUN
Power tuning
0RST
Zero reset
LOFF
Light OFF (The light will remain OFF as
long as the input is ON.)
ATC
ATC start
The teaching cannot be executed even.
8. Eco Mode Setting
Effective Pulse Widths
0.1 to 2 s
Executing: 0.1 to 2 s
Clearing: 3 s or longer
Effective ON pulse
width: 0.1 s min.
Selection
Pulse width
,
,
Effective pulse
width: 3 s
OFF
ECO1
Standard brightness.
Dims the display.
Turns off the display.
ECO2
D
C
D
C
When DIFF is selected for detection method ,ACT
function is diasabled.
B
A
LON
DON
A
B
STND
HRES
DIFF
SHS
HS
TG
Light level
Light level
Light level
Without the workpiece
ATC-Start is performed at the time of a
power supply injection.
ON
OFF
Disable counter.
The processing executed when the power supply is turned
on is selected.
Setting at power
supply ON
PTAT
Power tuning and ATC-Start is performed
at the time of a power supply injection.
The display turns on the key operation when the Eco-mode is effective.
It returns to the Eco-mode if there is no key operation for ten seconds.
Not
Maximum power
FULL
Setting range: 100 to 3,900, FULL
⑤
Positioning-teaching
It executes it puts on the place where it wants to position workpiece.
Setting
RUN
mode
Switch to RUN
mode.
Press the MODE key
for at least 3 seconds.
Press the MODE key
for at least 3 seconds.
Workpiece
RUN
SET
Workpiece
Refer to
①
2-point teaching for SET mode and display.
OMRON Corporation
Suitability for Use
EUROPE
OMRON EUROPE B.V. Sensor Business Unit
Carl-Benz Str.4, D-71154 Nufringen Germany
Phone:49-7032-811-0 Fax: 49-7032-811-199
NORTH AMERICA
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,IL 60173-5302 U.S.A.
Phone:1-847-843-7900 Fax : 1-847-843-7787
ASIA-PACIFIC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road #05-05-08(Lobby 2),
Alexandra Technopark, Singapore 119967
Phone : 65-6835-3011 Fax :65-6835-2711
o
THE PRODUCTS CONTAINED IN THIS SHEET ARE NOT SAFETY RATED.
THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY
COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES.
Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or
regulations that apply to the combination of the products in the customer's
application or use of the product.
Take all necessary steps to determine the suitability of the product for the
systems, machines, and equipment with which it will be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL
EQUIPMENT OR SYSTEM.
See also Product catalog for Warranty and Limitation of Liability.
CHINA
OMRON(CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Phone : 86-21-5037-2222 Fax :86-21-5037-2200
OCT, 2009
LOC
ON
Write results to EEPROM.
ON
OFF
Do not write results to EEPROM.
Whether external input execution results are written
to EEPROM can be selected. Disable this function
if the external input is turned ON frequently.
(The write life is approximately 100000 writes.)
11. External Input
Memory *
* The external input cannot be used though it is displayed
even by the wire-saving connector