background image

E3S

7

Adjustment Methods

 Adjusting the E3S-LS10XE4 Convergent-reflective 

Sensor

1. Attach the distance adjustment scale as shown in the figure 

and set it where the 

*

 mark is equal to the sensing distance.

2. Turn the distance adjuster until the red spot is at point 

 

(center of the distance adjustment scale).

3. Remove the distance adjustment scale once the distance 

has been adjusted. Put a sensing object in place, and then 
adjust the sensitivity.

 Adjusting the E3S-LS20XE4 Convergent-reflective 

Sensor

Adjustment Method 1

Use this method if the sensing object is more reflective than 
the background.

1. Set the sensitivity adjuster to the center as shown in the 

figure.

2. Turn the distance adjuster counterclockwise until it is fully 

turned (L to S).

3. Position the sensing object.
4. Slowly turn the distance adjuster clockwise (S to L).
5. Eventually the LIGHT (red) indicator will light. Turning the 

adjuster further will light the STABILITY (green) indicator.
Leave the distance adjuster at this level.

6. Adjust the sensitivity in this state.

Adjustment Method 2

Use this method if the background is more reflective than the 
sensing object.

1. Set the sensitivity adjuster to the center as shown in the 

figure.

2. Turn the distance adjuster clockwise until it is fully turned (S 

to L).

3. Remove the sensing object.
4. Slowly turn the distance adjuster counterclockwise (L to S).
5. Eventually the LIGHT (red) indicator will light. Turning the 

adjuster further will light the STABILITY (green) indicator.

6. Adjust the sensitivity in this state.

Distance adj

u

stment scale

Align the distance adj

u

stment scale 

w

ith the groo

v

e on the Sensor.

E3S-LS10XE4

A

Distance adj

u

ster

Sensiti

v

ity adj

u

stment

*

A

Distance adj

u

ster

Sensing o

b

ject

Center

Backgro

u

nd

o

b

ject

Distance adj

u

ster

Sensing o

b

ject

Center

Backgro

u

nd

o

b

ject

Summary of Contents for E3S

Page 1: ...10XE4 2M Convergent reflective wide vision field E3S LS20XE4 2M Through beam E3S 2E4 Emitter E3S 2LE4 Receiver E3S 2DE4 E3S 5E4 Emitter E3S 5LE4 Receiver E3S 5DE4 Retro reflective E3S R2E4 Diffuse ref...

Page 2: ...e p p 10 max Current consumption 50 mA max Emitter 25 mA max Receiver 25 mA max 40 mA max Control output solid state out put Output current 1 5 to 4 mA Load current 80 mA max residual voltage 2 V max...

Page 3: ...ing distance X mm Operating distance X Standard sensing object 50 x 50 mm Operating position 10 8 6 4 2 0 2 4 6 8 10 100 140 160 40 60 80 20 120 Y Y Optical axis Operating position Y mm Operating dist...

Page 4: ...0 60 40 20 0 2 8 2 4 2 1 6 1 2 3 2 0 8 0 4 Distance X Parallel movement distance Y Distance X m Parallel movement distance Y mm 10 000 5 000 3 000 1 000 500 300 100 50 30 0 140 160 60 40 80 100 120 20...

Page 5: ...rcuit Incident light No incident light ON OFF ON OFF Operate Reset H L Light indicator red Output transistor Load 1 e g relay Load 2 Between brown and black Between blue and black Brown 1 12 to 24 VDC...

Page 6: ...e wire Retro reflective Sensors Light Interrupted and Load Operating for E3S R2E4 41 42 DS10E4 41 and DS30E4 41 Connection with S3D2 Sensor Controller Reverse operation is possible using the signal in...

Page 7: ...e distance adjuster clockwise S to L 5 Eventually the LIGHT red indicator will light Turning the adjuster further will light the STABILITY green indicator Leave the distance adjuster at this level 6 A...

Page 8: ...may take time until the incident level and measurement value become stable immediately after the power is turned on depending on use environment 6 Burn injury may occur The product surface temperatur...

Page 9: ...different directions can be made Type Output type Output transistor Rated current output Switching current Output protection circuit E Voltage or current output NPN 1 5 to 4 mA 80 mA max sinking Provi...

Page 10: ...5 20 30 5 11 4 Indicator Two M3 a 1 Lens 7 dia 6 dia 12 8 dia Sensitivity adjuster 2 1 The mounting bracket can also be used on side a 2 Receiver only 4 dia vinyl insulated round cable with 2 3 conduc...

Page 11: ...ia a The mounting bracket can also be used on side a E3S DS10E41 20 4 32 6 5 4 2 2 1R 2 1R 4 2 5 25 4 39 1 9 55 67 13 7 11 20 23 7 1 22 2 20 5 20 12 22 24 9 1 6 Indicator Two M4 slotted hexagonal bolt...

Page 12: ...0 16 2 1R 34 20 26 11 6 3 4 2 17 24 4 2 5 11 70 1 6 Indicator Two M4 slotted hexagonal bolts Sensitivity adjuster Emitter Receiver 4 dia vinyl insulated round cable with 3 conductors Conductor cross s...

Page 13: ...20 33 4 20 3 2 68 5 60 8 20 28 5 4 Two M3 Mounting Holes Applicable models E3S 2E41 E3S DS10E41 20 Two M3 E39 L4 34 40 3 52 59 9 2 7 8 1 6 7 5 7 Two 3 5 dia Material Reflective surface Acrylic Rear su...

Page 14: ...x 2 mm and 11 x 4 mm 2 One set consists of two slits one each for the Emitter and Receiver Slit E39 S1 Applicable Sensors E3S 5E4 E3S 5E41 Note The dimensions in parentheses are for when the Spacer is...

Page 15: ...her in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: