background image

E3S

2

Ratings and Specifications

* The ambient operating illumination is the illumination that changes the output ±20% at 200 lx. It is not the operational limit.

Sensing method

Through-beam

Retro-re-

flective

Diffuse-reflective

Convergent-reflective

Item

Model

E3S-2E4
E3S-2E41

E3S-5E4
E3S-5E41 

E3S-R2E4
E3S-R2E41

E3S-
DS10E4
E3S-
DS10E41

E3S-
DS30E41

E3S-
DS30E4S

E3S-
LS10XE4

E3S-
LS20XE4

Sensing distance

2 m

5 m

0.1 to 2 m

100 mm
(white paper 
50 x 50 mm)

300 mm
(white paper 100 x 100)

30 to 100 mm
Continuously 
variable
(10 x 10 mm)

50 to 250 mm
Continuously 
variable 
(50 x 75 mm)

Standard sensing 
object

Opaque: 7-
mm dia. min.

Opaque: 11-
mm dia. min.

Opaque: 30-
mm dia. min.

Transparent, opaque

Differential travel

---

20% max. of setting distance

1.5 mm max. 
at 30 mm

5% max. at 50 
to 250 mm

10 mm max. 
at 100 mm

Directional angle

Both emitter and receiver: 
3

°

 to 10

°

3

°

 to 10

°

---

Light source 
(wavelength)

Infrared LED 
(950 nm)

RED LED
(660 nm)

Infrared LED 
(945 nm)

Power supply 
voltage

12 to 24 VDC

±

10%, ripple (p-p): 10% max.

Current 
consumption

50 mA max. 
(Emitter: 25 mA max., 
Receiver: 25 mA max.)

40 mA max.

Control output 
(solid-state out-
put)

Output current: 1.5 to 4 mA, Load current: 80 mA max. (residual voltage: 2 V max.) 

 Refer to page 4.

Response time

Operate or reset: 3 ms max. Operate or reset: 1 ms max.

Sensitivity 
adjustment

With an indicator

Ambient 
illumination 
(Receiver side) 

*

Incandescent lamp: 3,000 lx max.
Sunlight: 10,000 lx max.

Ambient 
temperature

Operating: 

25 to 55

°

C, Storage: 

40 to 70

°

C (with no icing or condensation)

Ambient humidity

Operating: 35% to 85%, Storage: 35% to 95% (with no condensation)

Insulation 
resistance

20 M

Ω 

min. at 500 VDC

Dielectric strength

1,000 VAC, 50/60 Hz for 1 min

Vibration 
resistance 
(destruction)

10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance
(destruction)

500 m/s

2

 3 times each in X, Y, and Z directions

Degree of 
protection

IEC IP65

IEC IP67

IEC IP65

IEC IP67

Connection 
method

Pre-wired cable (standard length: 2 m)

Indicators

Light indicator (red), Stability indicator (green)

Material

Case

Polybuty-
lene tereph-
thalate

Zinc die-cast

Polybuty-
lene tereph-
thalate

Zinc die-cast

Lens 

*

Polycarbonate

Mount-
ing 
Bracket

Iron

Summary of Contents for E3S

Page 1: ...10XE4 2M Convergent reflective wide vision field E3S LS20XE4 2M Through beam E3S 2E4 Emitter E3S 2LE4 Receiver E3S 2DE4 E3S 5E4 Emitter E3S 5LE4 Receiver E3S 5DE4 Retro reflective E3S R2E4 Diffuse ref...

Page 2: ...e p p 10 max Current consumption 50 mA max Emitter 25 mA max Receiver 25 mA max 40 mA max Control output solid state out put Output current 1 5 to 4 mA Load current 80 mA max residual voltage 2 V max...

Page 3: ...ing distance X mm Operating distance X Standard sensing object 50 x 50 mm Operating position 10 8 6 4 2 0 2 4 6 8 10 100 140 160 40 60 80 20 120 Y Y Optical axis Operating position Y mm Operating dist...

Page 4: ...0 60 40 20 0 2 8 2 4 2 1 6 1 2 3 2 0 8 0 4 Distance X Parallel movement distance Y Distance X m Parallel movement distance Y mm 10 000 5 000 3 000 1 000 500 300 100 50 30 0 140 160 60 40 80 100 120 20...

Page 5: ...rcuit Incident light No incident light ON OFF ON OFF Operate Reset H L Light indicator red Output transistor Load 1 e g relay Load 2 Between brown and black Between blue and black Brown 1 12 to 24 VDC...

Page 6: ...e wire Retro reflective Sensors Light Interrupted and Load Operating for E3S R2E4 41 42 DS10E4 41 and DS30E4 41 Connection with S3D2 Sensor Controller Reverse operation is possible using the signal in...

Page 7: ...e distance adjuster clockwise S to L 5 Eventually the LIGHT red indicator will light Turning the adjuster further will light the STABILITY green indicator Leave the distance adjuster at this level 6 A...

Page 8: ...may take time until the incident level and measurement value become stable immediately after the power is turned on depending on use environment 6 Burn injury may occur The product surface temperatur...

Page 9: ...different directions can be made Type Output type Output transistor Rated current output Switching current Output protection circuit E Voltage or current output NPN 1 5 to 4 mA 80 mA max sinking Provi...

Page 10: ...5 20 30 5 11 4 Indicator Two M3 a 1 Lens 7 dia 6 dia 12 8 dia Sensitivity adjuster 2 1 The mounting bracket can also be used on side a 2 Receiver only 4 dia vinyl insulated round cable with 2 3 conduc...

Page 11: ...ia a The mounting bracket can also be used on side a E3S DS10E41 20 4 32 6 5 4 2 2 1R 2 1R 4 2 5 25 4 39 1 9 55 67 13 7 11 20 23 7 1 22 2 20 5 20 12 22 24 9 1 6 Indicator Two M4 slotted hexagonal bolt...

Page 12: ...0 16 2 1R 34 20 26 11 6 3 4 2 17 24 4 2 5 11 70 1 6 Indicator Two M4 slotted hexagonal bolts Sensitivity adjuster Emitter Receiver 4 dia vinyl insulated round cable with 3 conductors Conductor cross s...

Page 13: ...20 33 4 20 3 2 68 5 60 8 20 28 5 4 Two M3 Mounting Holes Applicable models E3S 2E41 E3S DS10E41 20 Two M3 E39 L4 34 40 3 52 59 9 2 7 8 1 6 7 5 7 Two 3 5 dia Material Reflective surface Acrylic Rear su...

Page 14: ...x 2 mm and 11 x 4 mm 2 One set consists of two slits one each for the Emitter and Receiver Slit E39 S1 Applicable Sensors E3S 5E4 E3S 5E41 Note The dimensions in parentheses are for when the Spacer is...

Page 15: ...her in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Suitability of Use Omron Companies shall not be responsible for conformity...

Reviews: