Operating Procedures: Photoelectric Sensors
32
Remote Control Function (Bank Selection, Mark Registration, Threshold Adjustment)
In RUN mode and ADJUST mode, remote operation can be performed by inputting the signals in the following table for the remote
control input/answer-back output. There will be answer-back output for 0.3 s if the signal is correctly received.
Only one-point teaching can also be operated with manual input.
(Provide input for 1.5 s min.)
Timing Chart
*If consecutive signals are to be sent, allow an interval of at least 2.5 s after the
signal is input, as in the figure above.
Example of Ladder Programming
Control signals can be created using the example of ladder
programming shown in the following figure.
Control Signals
Note: Set input error of each signal pulse to within
±
0.1 s
E3S-CR62/67
Sensitivity Adjustment
The Sensor and reflector can be moved horizontally and vertically to set them in the center of the illumination area of the red incident light indicator,
allowing the operator to check whether the green stability indicator lamp is lit.
Remote control
input/output
ON
2.5 s min. *
1.5 s
2.0 s
Input signal
Next input
signal
Input judgment (1.8 s)
Setting
changes.
Sensing restarts.
0.3 s
OFF
Sensor operation
Answer-back output only if processing of
the signal is properly completed.
05001
05002
00100
05000
END
TIM000
#XXXX
TIM001
#YYYY
TIM002
#ZZZZ
05000
00000
T000
05001
T000
T001
05002
T001
T002
05002
05000
TIM000, TIM001, TIM002 set values
(XXXX, YYYY, ZZZZ)
No.1: (0000, 0000, 0003)
No.2: (0000, 0000, 0006)
No.3: (0000, 0000, 0009)
No.4: (0000, 0000, 00012)
No.5: (0000, 0000, 00015)
No.6: (0003, 0003, 0003)
No.7: (0003, 0006, 0003)
No.8: (0003, 0009, 0003)
No.9: (0003, 0003, 0006)
No.10: (0003, 0006, 0006)
No.11: (0003, 0003, 0009)
No.12: (0006, 0003, 0003)
Input: 00000
Output: 00100
Others: Work bits
No.
Control signal
Function
1
Bank 1 selection
(Operation indicator OFF in TEACH
mode)
2
Bank 2 selection
(Operation indicator lit in TEACH mode)
3
Automatic teaching
4
Two-point teaching (first and second)
5
One-point teaching (input of 1.5 s min.
also possible)
6
Threshold 1 selection
7
Threshold 3 selection
8
Threshold 5 selection
9
Threshold 7 selection
10
Threshold 9 selection
11
Threshold 11 selection
12
Threshold 13 selection
0.3 s
ON
OFF
0.6 s
ON
OFF
0.9 s
ON
OFF
1.2 s
ON
OFF
1.5 s
ON
OFF
0.3 s 0.3 s 0.3 s
ON
OFF
0.3 s 0.6 s 0.3 s
ON
OFF
0.3 s
0.9 s
0.3 s
ON
OFF
0.3 s 0.3 s 0.6 s
ON
OFF
0.3 s
0.6 s
0.6 s
ON
OFF
0.3 s 0.3 s
0.9 s
ON
OFF
0.3 s 0.3 s
0.6 s
ON
OFF
Sensing object
Detection state
Sensitivity adjuster
Indicator status
Adjustment procedure
Transparent
bottle or glass
plate
No sensing object
Turn the sensitivity adjuster from minimum
to maximum and set it at a point where the
incident light stabilizes.
Opaque object
Sensing object
or no sensing
object
If the object is larger than the lens
diameter, set the sensitivity control to the
maximum setting.If the object is the same
size or smaller, turn the sensitivity control
from minimum to maximum and set it at
point where the incident light stabilizes.
Min.
Max.
Stability
(green)
Light
(red)
ON
ON
Min.
Max.
Stability
(green)
Light
(red)
ON
ON