Operating Procedures: Photoelectric Sensors

32

Remote Control Function (Bank Selection, Mark Registration, Threshold Adjustment)

In RUN mode and ADJUST mode, remote operation can be performed by inputting the signals in the following table for the remote 
control input/answer-back output. There will be answer-back output for 0.3 s if the signal is correctly received.
Only one-point teaching can also be operated with manual input.
(Provide input for 1.5 s min.)

Timing Chart

*If consecutive signals are to be sent, allow an interval of at least 2.5 s after the 

signal is input, as in the figure above. 

Example of Ladder Programming

Control signals can be created using the example of ladder 
programming shown in the following figure.

Control Signals

Note: Set input error of each signal pulse to within 

±

0.1 s

E3S-CR62/67

Sensitivity Adjustment

The Sensor and reflector can be moved horizontally and vertically to set them in the center of the illumination area of the red incident light indicator, 

allowing the operator to check whether the green stability indicator lamp is lit.

Remote control 
input/output

ON

2.5 s min. *

1.5 s

2.0 s

Input signal

Next input 
signal

Input judgment (1.8 s)

Setting 

changes.

Sensing restarts.

0.3 s

OFF

Sensor operation

Answer-back output only if processing of 
the signal is properly completed.  
 

05001

05002

00100

05000

END

TIM000

#XXXX

TIM001

#YYYY

TIM002

#ZZZZ

05000

00000

T000

05001

T000

T001

05002

T001

T002

05002

05000

TIM000, TIM001, TIM002 set values

(XXXX, YYYY, ZZZZ)

No.1: (0000, 0000, 0003)
No.2: (0000, 0000, 0006)
No.3: (0000, 0000, 0009)
No.4: (0000, 0000, 00012)
No.5: (0000, 0000, 00015)
No.6: (0003, 0003, 0003)
No.7: (0003, 0006, 0003)
No.8: (0003, 0009, 0003)
No.9: (0003, 0003, 0006)
No.10: (0003, 0006, 0006)
No.11: (0003, 0003, 0009)
No.12: (0006, 0003, 0003)

Input: 00000
Output: 00100
Others: Work bits

No.

Control signal

Function

1

Bank 1 selection
(Operation indicator OFF in TEACH 
mode)

2

Bank 2 selection
(Operation indicator lit in TEACH mode)

3

Automatic teaching

4

Two-point teaching (first and second)

5

One-point teaching (input of 1.5 s min. 
also possible)

6

Threshold 1 selection

7

Threshold 3 selection

8

Threshold 5 selection

9

Threshold 7 selection

10

Threshold 9 selection

11

Threshold 11 selection

12

Threshold 13 selection

0.3 s

ON

OFF

0.6 s

ON

OFF

0.9 s

ON

OFF

1.2 s

ON

OFF

1.5 s

ON

OFF

0.3 s 0.3 s 0.3 s

ON

OFF

0.3 s 0.6 s 0.3 s

ON

OFF

0.3 s

0.9 s

0.3 s

ON

OFF

0.3 s 0.3 s 0.6 s

ON

OFF

0.3 s

0.6 s

0.6 s

ON

OFF

0.3 s 0.3 s

0.9 s

ON

OFF

0.3 s 0.3 s

0.6 s

ON

OFF

Sensing object

Detection state

Sensitivity adjuster

Indicator status

Adjustment procedure

Transparent 
bottle or glass 
plate

No sensing object

Turn the sensitivity adjuster from minimum 
to maximum and set it at a point where the 
incident light stabilizes.

Opaque object

Sensing object 
or no sensing 
object

If the object is larger than the lens 
diameter, set the sensitivity control to the 
maximum setting.If the object is the same 
size or smaller, turn the sensitivity control 
from minimum to maximum and set it at 
point where the incident light stabilizes.

Min.

Max.

Stability

(green)

Light
(red)

ON

ON

Min.

Max.

Stability 

(green)

Light
(red)

ON

ON