![background image](http://html1.mh-extra.com/html/omron/e3m-v/e3m-v_manual_741090004.webp)
E3M-V
E3M-V
4
Nomenclature
Operation Indicator (Orange)
Lit when the output is ON.
Detection Level Indicators (Green)
Displays the detection level.
SET Button
Used for teaching and threshold
adjustments.
Threshold Indicators (Red)
Displays the threshold level.
Mode Selector
Selects the mode.
UP/DOWN Selector
Increases the threshold value when
set to UP.
Decreases the threshold value when
set to DOWN.
Operation
Output Circuits
Detection
level indi-
cators
(green,
8 levels)
Threshold
indicators
(red,
7 levels)
Main
circuit
Operation
indicator
(orange)
Remote control input
/Answer-back output
Load
Load
Control
output
Brown
White
Black
Blue
Detection
level indi-
cators
(green,
8 levels)
Threshold
indicators
(red,
7 levels)
Main
circuit
Operation
indicator
(orange)
Load
Load
10 to 30 VDC
Control
output
Brown
White
Black
Blue
(See note.)
(See note.)
Remote control input
/Answer-back output
NPN (E3M-VG11, E3M-VG21)
PNP (E3M-VG16, E3M-VG26)
10 to 30 VDC
Connector Pin Arrangement
1
2
4
3
1
4
2
3
100 mA max.
Note:
Remote control input and answer-back output share the same line. Be sure to connect the load as shown above if the remote control
function is used.