Standard Photoelectric Sensors

Output Circuit Diagram

E3JK

Relay output

DC transistor output

Note: Connect to brown and blue on the emitter side.

Model

Timing chart

Output circuit

E3JK-5M1
E3JK-5M2

E3JK-R2M1
E3JK-R2M2
E3JK-R4M1
E3JK-R4M2

E3JK-DS30M1
E3JK-DS30M2

Model

Timing chart

Output circuit

E3JK-R2S3
E3JK-R4S3

E3JK-DS30S3

E3JK-R2R3

Light indicator
(red)

L-ON(Ta)
(E3JK-

##

M1)

D-ON(Ta)
(E3JK-

##

M2)

Incident

Interrupted

ON

OFF

ON

OFF

ON

OFF

Power

source

Main circuit

(Polarity Optional)

24 to 240 VAC
12 to 240 VDC

White

Brown

Blue

Black

Contact output

Tc

Tb

Ta

Gray

Built-in relay: G6C

Light
indicator
(red)

L-ON mode

D-ON mode

Incident

Interrupted

ON

OFF

ON

OFF

ON

OFF

Main 
circuit 

Power 
source 

Load

Load

Brown

Blue

White

Gray (D-ON)

Black (L-ON)

Drive 
circuit

Drive 
circuit

24 to 240 VAC 
12 to 240 VDC

Light
indicator
(red)

L-ON mode

D-ON mode

Incident

Interrupted

ON

OFF

ON

OFF

ON

OFF

Power

source

(Polarity

Optional)

24 to 240 VAC
12 to 240 VDC

Main 
circuit

Drive

circuit

Drive

circuit

D/ON

L/ON

Gray

Black

48 VDC max.

White

Load

Load

I

1

I

2

I1 + I2 < 100 mA

Brown

Blue

Note: The output stage leakage currents are 0.1 mA max., respectively.

Summary of Contents for E3JK

Page 1: ...elay output E3JK 5M1 Dark ON E3JK 5M2 Retroreflective model with M S R function Light ON Relay output E3JK R2M1 Dark ON E3JK R2M2 Light ON Dark ON selectable DC transistor output NPN E3JK R2S3 PNP E3J...

Page 2: ...rd Photoelectric Sensors Mounting Brackets Note If a through beam model is used order two Mounting Brackets for the emitter and receiver respectively Shape Model Quantity Remarks E39 L40 1 Supplied wi...

Page 3: ...circuit protection Relay output 250VAC 3 A cos 1 max 5 VDC 10 mA min DC SSR Negative com mon 48 VDC 100 mA max Leak current 0 1 mA max With load short circuit protec tion Relay output 250VAC 3 A cos 1...

Page 4: ...irections Destruction 100 m s2 approx 10G 3 times each in X Y and Z direc tions Destruction 500 m s2 for 3 times each in X Y and Z directions Protective structure IEC60529 IP64 Connection method Pre w...

Page 5: ...500 300 100 50 30 10 5 3 1 Setting distance m 1 0 2 3 4 5 6 7 8 Operating voltage Excess gain ratio 100 50 30 10 5 3 1 Setting distance m 1 0 2 3 4 Operating voltage Reflector E39 R1 Excess gain rati...

Page 6: ...Polarity Optional 24 to 240 VAC 12 to 240 VDC White Brown Blue Black Contact output Tc Tb Ta Gray Built in relay G6C Light indicator red L ON mode D ON mode Incident Interrupted ON OFF ON OFF ON OFF...

Page 7: ...enter of the range where the indicator of the re ceiver turns ON Like the through beam model ad just the reflector and emitter re ceiver Since the directional angle of the emitter receiver is 1 to 5 a...

Page 8: ...12 Sensitivity adjustment volume 2 42 50 40 58 10 R56 6 40 5 Optical axis 40 25 Steel 13 4 28 50 Lens Light indicator 18 60 4 9 18 6 dia 7 6 4 22 40 12 6 4 Emitter Receiver 1 Mounting brackets can be...

Reviews: