![background image](http://html1.mh-extra.com/html/omron/e3fr/e3fr_datasheet_741057007.webp)
7
E3FZ/E3FR
Specification
Item
Background suppression (BGS)
E
3
FZ-LS
@
1H / E
3
FR-LS
@
1H
E
3
FZ-LS
@
6H / E
3
FR-LS
@
6H
E
3
FZ-LS
@
4H / E
3
FR-LS
@
4H
E
3
FZ-LS
@
9H / E
3
FR-LS
@
9H
Sensing distance
10 to 100 mm (White paper 100x100 mm)
10 to 200 mm (White paper 100x100 mm)
Spot diameter
4 mm dia. at sensing distance of 100 mm
18 mm dia. at sensing distance of 200 mm
Standard sensing o
b
ject
–
Differential travel
3
% of sensing distance max.
20% of sensing distance max.
Black/white error
5% of sensing distance max.
20% of sensing distance max.
Directional angle
–
Light source (wave length)
Red LED (650 nm)
Red LED (660 nm)
Power supply voltage
10 to
3
0 VDC, including 10% ripple(p-p)
Current consumption
25 mA max.
Control output
Load power supply voltage;
3
0 VDC max., Load current; 100 mA max. (Residual voltage; 2 V max.),
Light-on/Dark-on selecta
b
le
b
y wire,
E
3
F
@
-LS6: NPN open-collector output
E
3
F
@
-LS8: PNP open-collector output
Protective circuits
Power supply reverse polarity protection, output short-circuit protection,
mutual interference prevention and reversed output polarity protection
Response time
Operate and reset; 1 ms max.
Sensitivity adjustment
–
Am
b
ient illumination
(receiver side)
Incandescent lamp;
3
000 lx max., Sunlight 10000 lx max.
Am
b
ient temperature
Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Am
b
ient humidity
Operating;
3
5 to 85%RH, Storage;
3
5 to 95%RH (with no condensation)
Insulation resistance
20M
Ω
min. at 500 VDC
Dielectric resistance
1000 VAC at 50/60 Hz for 1 min
Vi
b
ration resistance
Destruction; 10 to 55 Hz, 1.5 mm dou
b
le amplitude for 2 hours, each in X, Y and Z directions
Shock resistance
Destruction; 500m/s
2
,
3
times, each in X, Y and Z directions
Degree of protection
*
1
*
1.
The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80ºC is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
IEC 60529 IP67, IP69K after DIN 40050-9
Connection method
Pre-wired ca
b
le (standard length 2m), Standard M12 connector
Indicator
Operation indicator: yellow, sta
b
ility indicator: green
Weight
(packed state)
Pre-wired
approx.60g
Standard
connector
approx.20g
Material
Case
ABS
Cover-lens
Plate-window
PMMA
Accessories
Instruction sheet, 2x M18 nuts, snap mounting tool (E
3
FZ only).
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 7 Dienstag, 15. April 2008 5:17 17