Standard Photoelectric Sensors
Specifications
Item
Through-
b
eam
Retroreflective
Diffuse reflective
E
3
FZ-T / E
3
FR-T
E
3
FZ-R / E
3
FR-R
E
3
FZ-D / E
3
FR-D
Sensing distance
15 m
4 m [100 mm]
1 m (white paper
3
00x
3
00 mm)
Spot diameter
–
Standard sensing o
b
ject
Opa
q
ue: 12 mm dia .min
Opa
q
ue: 75 mm dia. min
–
Differential travel
–
20% max. of sensing distance
max.
Black/white error
–
Directional angle
Emitter and Reciever:
3
° to 15°
Sensor:
3
° to 10°, Reflector:
3
0° –
Light source (wave length)
Infrared LED (870 nm)
Red LED (660 nm)
Infrared LED (860 nm)
Power supply voltage
10 to
3
0 VDC, including 10% ripple(p-p)
Current consumption
45mA max.
(Emitter: 25mA max.,
Receiver; 20 mA max. )
25 mA max.
Control output
Load power supply voltage;
3
0 VDC max., Load current; 100 mA max.(Residual voltage; 2 V max.),
Light-on/Dark-on selecta
b
le
b
y wire,
E
3
F
@
-6
@
: NPN open-collector output
E
3
F
@
-8
@
: PNP open-collector output
Protective circuits
Power supply reverse polarity
protection, output short-circuit
protection, and reversed output
polarity protection
Power supply reverse polarity protection,
output short-circuit protection, mutual interference prevention and
reversed output polarity protection
Response time
Operate and reset; 1 ms max.
Sensitivity adjustment
–
One-turn adjuster
Am
b
ient illumination
(receiver side)
Incandescent lamp;
3
000 lx max., Sunlight 10000 lx max.
Am
b
ient temperature
Operating; -25 to +55°C, Storage; -40 to +70°C (with no icing or condensation)
Am
b
ient humidity
Operating;
3
5 to 85% RH, Storage;
3
5 to 95% RH (with no condensation)
Insulation resistance
20M
Ω
min. at 500 VDC
Dielectric resistance
1000 VAC at 50/60 Hz for 1 min
Vi
b
ration resistance
Destruction; 10 to 55 Hz, 1.5 mm dou
b
le amplitude for 2 hours, each in X, Y and Z directions
Shock resistance
Destruction; 500 m/s
2
,
3
times, each in X, Y and Z directions
Degree of protection
*
1
*
1.
The IP69k test according to DIN 40 050 part 9 is intended to simulate high pressure/steam cleaning. During the test 14-16 l/min water
at 80°C is sprayed onto the sensor from different angles with 8000-10000 kPa. The sensor may not suffer any damaging effects from
high pressure water in appearance and functionality.
IEC 60529 IP67, IP69K after DIN 40050-9
Connection method
Pre-wired ca
b
le (standard length 2 m), Standard M12 connector
Indicator
Operation indicator: yellow, sta
b
ility indicator: green
(Emitter has only power supply indicator; green)
Weight
(packed state)
Pre-wired
approx. 120 g
approx. 60 g
Standard
connector
approx. 40 g
approx. 20 g
Material
Case
ABS
Cover lens
Plate window
PMMA
Accessories
Instruction sheet, 2x M18 nuts, snap mounting tool (E
3
FZ only).
E55E-EN-01+E3FZ-E3FR+Datasheet.FM Seite 6 Dienstag, 15. April 2008 5:17 17